EFFECT OF RATE AND COUPLING INTERVAL ON ENDOCARDIAL-R WAVE AMPLITUDE VARIABILITY IN PERMANENT VENTRICULAR SENSING LEAD SYSTEMS

被引:12
作者
CALLANS, DJ
HOOK, BG
MARCHLINSKI, FE
机构
[1] HOSP UNIV PENN,CLIN PHYSIOL LAB,PHILADELPHIA,PA 19104
[2] UNIV PENN,DEPT MED,CARDIOVASC SECT,PHILADELPHIA,PA 19104
关键词
D O I
10.1016/0735-1097(93)90186-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. We have observed sensing errors in third generation implantable cardioverter-defibrillators that appear to be caused by variation in the R wave amplitude during sinus rhythm, particularly after premature beats. The purpose of this study was to quantify spontaneous R wave variability during sinus rhythm and to determine whether abrupt changes in cycle length further augment R wave amplitude variability. Background. Pacemaker sensing algorithms presume a relatively constant R wave signal to establish a sensing threshold. The concept of a fixed sensing threshold is not as applicable in third-generation cardioverter-defibrillators, which depend on automatic gain amplifiers to rapidly detect ventricular fibrillation. These devices may be susceptible to undersensing during sinus rhythm if significant variability in R wave signal characteristics occurs. Methods. Twelve patients with combination bradycardia pacing cardioverter-defibrillators were studied. The device used (Cadence, Ventritex) allowed recording of real time, telemetered electrograms from the sensing lead system. Measurements were made of the maximal range of the R wave amplitude during sinus rhythm and in response to abrupt changes in heart rate produced by premature atrial and ventricular stimuli. Results. The maximal range in R wave amplitude during sinus rhythm was 1.7 +/- 1.3 mV, or 23.7 +/- 19.2% of the mean R wave amplitude. The R wave amplitude variability increased with abrupt changes in cycle length, with a range of 2.8 +/- 1.5 mV, or 38.8 +/- 18.3% of the mean R wave amplitude (p < 0.05 compared with sinus rhythm). In most patients, R wave amplitude and coupling interval demonstrated an inverse proportional relation. Conclusions. There is substantial variability in the R wave amplitude during sinus rhythm measured by permanent ventricular sensing lead systems, and this variability is further augmented by abrupt changes in cycle length. This phenomenon may explain the occurrence of undersensing of sinus rhythm in implantable cardioverter-defibrillators with automatic gain sense amplifiers.
引用
收藏
页码:746 / 750
页数:5
相关论文
共 15 条
[1]   RELATIONSHIP OF QRS AMPLITUDE CHANGES DURING EXERCISE TO LEFT-VENTRICULAR FUNCTION AND VOLUMES AND THE DIAGNOSIS OF CORONARY-ARTERY DISEASE [J].
BATTLER, A ;
FROELICHER, V ;
SLUTSKY, R ;
ASHBURN, W .
CIRCULATION, 1979, 60 (05) :1004-1013
[2]   EVALUATION OF R-WAVE AMPLITUDE CHANGES VERSUS ST-SEGMENT DEPRESSION IN STRESS TESTING [J].
BONORIS, PE ;
GREENBERG, PS ;
CHRISTISON, GW ;
CASTELLANET, MJ ;
ELLESTAD, MH .
CIRCULATION, 1978, 57 (05) :904-910
[3]   DECREASE IN CANINE ENDOCARDIAL AND EPICARDIAL ELECTROGRAM VOLTAGES WITH EXERCISE - IMPLICATIONS FOR PACEMAKER SENSING [J].
BRICKER, JT ;
WARD, KA ;
ZINNER, A ;
GILLETTE, PC .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (04) :460-464
[4]   PACED BEATS FOLLOWING SINGLE NONSENSED COMPLEXES IN A CODEPENDENT CARDIOVERTER DEFIBRILLATOR AND BRADYCARDIA PACING SYSTEM - POTENTIAL FOR VENTRICULAR-TACHYCARDIA INDUCTION [J].
CALLANS, DJ ;
HOOK, BG ;
MARCHLINSKI, FE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (08) :1281-1287
[5]  
CALLANS DJ, 1991, CIRCULATION, V84, P428
[6]  
CHATTERJEE K, 1972, BRIT HEART J, V34, P271
[7]  
EINTHOVEN W, 1908, ARCH GES PHYSL MENSC, V122, P571
[8]  
FROLIG G, 1988, J AM COLL CARDIOL, V11, P806
[9]  
FROLIG G, 1988, PACE, V11, P47
[10]  
LEKVEN J, 1978, BRIT HEART J, V40, P891