Cohort study of the pathogenesis and molecular epidemiology of catheter-related bloodstream infection in neonates with peripherally inserted central venous catheters

被引:88
作者
Garland, Jeffery S. [1 ]
Alex, Colleen P. [1 ]
Sevallius, Jackie M. [1 ]
Murphy, Dawn M. [1 ]
Good, Mary J. [1 ]
Volberding, Annette M. [1 ]
Hofer, Leslie L. [1 ]
Gordon, Barbara J. [2 ]
Maki, Dennis G. [2 ]
机构
[1] Wheaton Franciscan Healthcare St Joseph, Dept Pediat, Milwaukee, WI USA
[2] Univ Wisconsin, Sch Med, Madison, WI USA
关键词
D O I
10.1086/526439
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objective. To better define the pathogenesis of catheter-related bloodstream infection ( BSI) in neonates with peripherally inserted central venous catheters (PICCs) to guide the development of more effective strategies for prevention. Design. Prospective nested cohort study. Setting. Level III neonatal intensive care unit in a community hospital. Methods. During a randomized trial to assess the safety and efficacy of a prophylactic vancomycin-heparin catheter-lock solution for the prevention of catheter-related BSI in neonates with PICCs, we performed cultures of peripheral and catheter-drawn blood samples, and quantitative cultures of catheter hub samples if BSI was suspected clinically. We performed semiquantitative cultures of the catheter tip and the catheter hub and the skin at the insertion site when the catheter was removed. Molecular subtyping by pulsed-field electrophoresis was used to determine the probable pathogenesis of all BSIs due to coagulase-negative staphylococci (CoNS); for BSIs caused by other microorganisms, epidemiologic concordance was based on speciation and antibiograms. Catheter-related BSI was considered extraluminally acquired if concordance was demonstrable solely between isolates recovered from the catheter tip and the blood, independent of concordance with isolates recovered from the insertion site. Catheter-related BSI was considered intraluminally acquired if concordance was demonstrated only between isolates recovered from the catheter hub and the blood. The source of the infection was considered indeterminate if both concordance patterns were present. Results. Nosocomial BSI was identified in 23 of the 82 neonates in the cohort. Fifteen of these infections, 14 of which were caused by CoNS, were considered definite or probable catheter-related BSIs. Catheter-related BSI was intraluminally acquired in 10 (67%) of 15 patients, extraluminally acquired in 3 (20%), and indeterminate in 2 (13%). Conclusions. Most catheter-related BSIs in neonates with PICCs are caused by CoNS and derive from intraluminal contamination. Strategies for prevention of catheter-related BSI directed at this predominant mechanism of infection are most likely to be effective.
引用
收藏
页码:243 / 249
页数:7
相关论文
共 37 条
[21]   EVALUATION OF DRESSING REGIMENS FOR PREVENTION OF INFECTION WITH PERIPHERAL INTRAVENOUS CATHETERS - GAUZE, A TRANSPARENT POLYURETHANE DRESSING, AND AN IODOPHOR-TRANSPARENT DRESSING [J].
MAKI, DG ;
RINGER, M .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1987, 258 (17) :2396-2403
[22]   Prevention of central venous catheter-related bloodstream infection by use of an antiseptic-impregnated catheter - A randomized, controlled trial [J].
Maki, DG ;
Stolz, SM ;
Wheeler, S ;
Mermel, LA .
ANNALS OF INTERNAL MEDICINE, 1997, 127 (04) :257-+
[23]   SEMIQUANTITATIVE CULTURE METHOD FOR IDENTIFYING INTRAVENOUS-CATHETER-RELATED INFECTION [J].
MAKI, DG ;
WEISE, CE ;
SARAFIN, HW .
NEW ENGLAND JOURNAL OF MEDICINE, 1977, 296 (23) :1305-1309
[24]  
MAKI DG, 1998, 38 INT C ANT AG CHEM
[25]   Use of semi-quantitative and quantitative culture methods and typing for studying the epidemiology of central venous catheter-related infections in neonates on parenteral nutrition [J].
Mueller-Premru, M ;
Gubina, M ;
Kaufmann, ME ;
Primozic, J ;
Cookson, BD .
JOURNAL OF MEDICAL MICROBIOLOGY, 1999, 48 (05) :451-460
[26]   Guidelines for the prevention of intravascular catheter-related infections [J].
O'Grady, NP ;
Alexander, M ;
Dellinger, EP ;
Gerberding, JL ;
Heard, SO ;
Maki, DG ;
Masur, H ;
McCormick, RD ;
Mermel, LA ;
Pearson, ML ;
Raad, II ;
Randolph, A ;
Weinstein, RA .
CLINICAL INFECTIOUS DISEASES, 2002, 35 (11) :1281-1307
[27]   ULTRASTRUCTURAL ANALYSIS OF INDWELLING VASCULAR CATHETERS - A QUANTITATIVE RELATIONSHIP BETWEEN LUMINAL COLONIZATION AND DURATION OF PLACEMENT [J].
RADD, I ;
COSTERTON, W ;
SABHARWAL, U ;
SACILOWSKI, M ;
ANAISSIE, E ;
BODEY, GP .
JOURNAL OF INFECTIOUS DISEASES, 1993, 168 (02) :400-407
[28]   Risk of catheter-related bloodstream infection with peripherally inserted central venous catheters used in hospitalized patients [J].
Safdar, N ;
Maki, DG .
CHEST, 2005, 128 (02) :489-495
[29]   The pathogenesis of catheter-related bloodstream infection with noncuffed short-term central venous catheters [J].
Safdar, N ;
Maki, DG .
INTENSIVE CARE MEDICINE, 2004, 30 (01) :62-67
[30]   A PROSPECTIVE-STUDY OF THE CATHETER HUB AS THE PORTAL OF ENTRY FOR MICROORGANISMS CAUSING CATHETER-RELATED SEPSIS IN NEONATES [J].
SALZMAN, MB ;
ISENBERG, HD ;
SHAPIRO, JF ;
LIPSITZ, PJ ;
RUBIN, LG .
JOURNAL OF INFECTIOUS DISEASES, 1993, 167 (02) :487-490