High migration rate of two types of threaded acetabular cups

被引:14
作者
Fink, B
Protzen, M
Hansen-Algenstaedt, N
Berger, J
Rüther, W
机构
[1] Univ Hamburg, Hosp Eppendorf, Dept Orthopaed, D-20246 Hamburg, Germany
[2] Clin Rheumatol Bad Bramstedt, Dept Orthopaed, D-24576 Bad Bramstedt, Germany
[3] Univ Hamburg, Hosp Eppendorf, Inst Math & Comp Sci Med, D-20246 Hamburg, Germany
关键词
threaded acetabular cup; loosening; migration; radiologic analysis;
D O I
10.1007/s00402-003-0592-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction. Survivorship analysis was performed on 479 Link V-type threaded cups and on 110 modified V-type Bad Bramstedt cups (a modification of the Link V-type cup since 1993 with a smaller primary coil) to evaluate the effect of the modifications. Materials and methods. Indication for hip arthroplasty with a Link V-type cup was an inflammatory arthritis in 310 patients, osteoarthritis in 138 patients and dysplastic hip joints in 31 patients. The average follow-up was 8.6+/-3.2 (range 3.0-15.2) years. The 110 modified V-type Bad Bramstedt cups had a mean follow-up period of 4.5+/-0.7 (range 3.0-5.9) years, including 49 with inflammatory arthritis, 49 with osteoarthritis and 12 with dysplastic hip joints. To evaluate the migration rate and radiolucent lines, radiographical examination according to the method of Nunn et al. and Delee and Charnley was performed on 264 Link V-type cups with a mean follow-up period of 8.2+/-2.7 years and 59 modified V-type Bad Bramstedt cups with a mean follow-up period of 4.6+/-0.7 years. Relevant parameters influencing cup migration were analysed. Results. The cumulative survival rate of the former Link V-type acetabular cup was 94.5% after 5 years, 88.1% after 10 years and 70.2% after 15 years. The Bad Bramstedt cup showed a 5-year survivorship rate of 97.9%. Migration of more than 3 mm or tilting of the cup greater than 5 degrees was found in 73% of the former type and in 39% of the modified cup. Radiolucent lines greater than 2 mm and detectable in two zones appeared in 6.4% of the former Link V-type and in 1.7% of the Bad Bramstedt cup design. Among the influencing factors analysed, length of follow-up and primary cup positioning showed a significant correlation to cup migration. Conclusion. The modification of the Link V-type cup showed no satisfactory improvement in cup migration. Therefore, both threaded cups were abandoned in favour of cementless press-fit cups.
引用
收藏
页码:17 / 25
页数:9
相关论文
共 42 条
[31]
ONSTEN I, 1995, CLIN ORTHOP RELAT R, P103
[32]
SOCKET MIGRATION AFTER CHARNLEY ARTHROPLASTY IN RHEUMATOID-ARTHRITIS AND OSTEOARTHRITIS - A ROENTGEN STEREOPHOTOGRAMMETRIC STUDY [J].
ONSTEN, I ;
BENGNER, U ;
BESJAKOV, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (05) :677-680
[33]
The effect of superior placement of the acetabular component on the rate of loosening after total hip arthroplasty - Long-term results in patients who have Crowe type-II congenital dysplasia of the hip [J].
Pagnano, MW ;
Hanssen, AD ;
Lewallen, DG ;
Shaughnessy, WJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (07) :1004-1014
[34]
PELLICCI PM, 1982, CLIN ORTHOP RELAT R, P34
[35]
CONTACT FINITE-ELEMENT STRESS-ANALYSIS OF POROUS INGROWTH ACETABULAR CUP IMPLANTATION, INGROWTH, AND LOOSENING [J].
RAPPERPORT, DJ ;
CARTER, DR ;
SCHURMAN, DJ .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1987, 5 (04) :548-561
[36]
The effect of anatomical positional relationships on kinetic parameters after total hip replacement [J].
Rösler, J ;
Perka, C .
INTERNATIONAL ORTHOPAEDICS, 2000, 24 (01) :23-27
[37]
Middle-term results of threaded acetabular cups - High failure rates five years after surgery [J].
Simank, HG ;
Brocai, DRC ;
Reiser, D ;
Thomsen, M ;
Sabo, D ;
Lukoschek, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (03) :366-370
[38]
PRIMARY MIGRATION OF FULLY-THREADED ACETABULAR PROSTHESES - A ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS [J].
SNORRASON, F ;
KARRHOLM, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (04) :647-652
[40]
CEMENTLESS UNCOATED POLYETHYLENE ACETABULAR COMPONENTS IN TOTAL HIP-REPLACEMENT - REVIEW OF 5-YEAR TO 10-YEAR RESULTS [J].
WILSONMACDONALD, J ;
MORSCHER, E ;
MASAR, Z .