Accurate spectral scans of single chromatographic peaks

被引:5
作者
Singh, H [1 ]
Aue, WA [1 ]
机构
[1] DALHOUSIE UNIV,DEPT CHEM,HALIFAX,NS B3H 4J3,CANADA
关键词
spectral scans; detection; GC; ferrocene; tris(pentafluorophenyl)phosphine; butyldisulfide;
D O I
10.1016/0021-9673(96)00294-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A detector equipped with two channels can fetch accurate luminescence spectra either from migrating chromatographic peaks or from other inputs of sharply varying concentration. To achieve this, one (the scanning) channel is continually referenced to another (the constant-wavelength) channel: the ratio of the two hence portrays correctly the intensity distribution of the spectrum. As a model system tor testing this ratio approach on single gas chromatographic peaks, a flame photometric detector was connected to a 1/8-m scanning spectrophotometer. No significant differences were found in relative spectral amplitudes between scanning the ascent versus the descent of a peak. Similar spectral constancy was obtained when scanning non-chromatographic variable inputs. With a view to practical use, three experiments were carried out that demonstrated the sensitivity and/or the spectral resolution obtainable from reference scans of single peaks. To wit, 5 pg of phosphorus produced a clearly recognizable HPO spectrum: the vibrational levels of S-2 resolved well; and the presence/absence of atomic iron lines confirmed an earlier postulated energy limit for the chemiluminescent excitation reaction.
引用
收藏
页码:43 / 51
页数:9
相关论文
共 24 条
[1]  
AUD WA, 1994, J CHROMATOGR A, V687, P283
[2]   FLAME PHOTOMETRIC DETECTION OF SOME TRANSITION-METALS .2. ENHANCEMENT OF SELECTIVITY [J].
AUE, WA ;
MILLIER, B ;
SUN, XY .
CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1992, 70 (04) :1143-1155
[3]   ELEMENTAL SPECIFICITY IN DUAL-CHANNEL FLAME PHOTOMETRIC DETECTION OF GAS-CHROMATOGRAPHIC PEAKS [J].
AUE, WA ;
MILLIER, B ;
SUN, XY .
ANALYTICAL CHEMISTRY, 1991, 63 (24) :2951-2955
[4]   DEVELOPMENT OF A HECD LASER-BASED FLUORESCENCE DETECTOR FOR ANALYSIS OF DERIVATIZED BIOGENIC-AMINES [J].
BOSTICK, JM ;
STROJEK, JW ;
METCALF, T ;
KUWANA, T .
APPLIED SPECTROSCOPY, 1992, 46 (10) :1532-1539
[5]  
BOWMAN MC, 1968, ANAL CHEM, V40, P1449
[6]   FLAME PHOTOMETRIC DETECTOR - APPLICATION OF A SPECIFIC DETECTOR FOR PHOSPHORUS AND FOR SULFUR COMPOUNDS-SENSITIVE TO SUBNANOGRAM QUANTITIES [J].
BRODY, SS ;
CHANEY, JE .
JOURNAL OF GAS CHROMATOGRAPHY, 1966, 4 (02) :42-&
[7]  
Dressler M., 1986, SELECTIVE GAS CHROMA, V36
[8]   BACKGROUND CORRECTION DEVICE FOR ENHANCED ELEMENT-SELECTIVE GAS-CHROMATOGRAPHIC DETECTION BY ATOMIC-EMISSION SPECTROSCOPY [J].
FARNSWORTH, PB ;
WU, MG ;
TACQUARD, M ;
LEE, ML .
APPLIED SPECTROSCOPY, 1994, 48 (06) :742-746
[9]  
*HAM CORP, CAT HAM CORP
[10]  
HASTINGS CR, 1974, TRACE SUBSTANCES ENV, V8, P265