Multiplexed readout of superconducting bolometers

被引:29
作者
Benford, DJ
Allen, CA
Chervenak, JA
Freund, MM
Kutyrev, AS
Moseley, SH
Shafer, RA
Staguhn, JG
Grossman, EN
Hilton, GC
Irwin, KD
Martinis, JM
Nam, SW
Reintsema, OD
机构
[1] NASA, Goddard Space Flight Ctr, Greenbelt, MD 20771 USA
[2] NIST, Boulder, CO 80305 USA
来源
INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES | 2000年 / 21卷 / 12期
关键词
bolometers; SQUIDs; multiplexing; transition edge sensors; far infrared; submillimeter;
D O I
10.1023/A:1006752416612
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Studies of emission in the far-infrared and submillimeter from astrophysical sources require large arrays of detectors containing hundreds to thousands of elements. A multiplexed readout is necessary for practical implementation of such arrays, and can be developed using SQUIDs, such that, e.g., a 32x32 array of bolometers can be read out using similar to 100 wires rather than the >2000 needed with a brute force expansion of existing arrays. These bolometer arrays are made by micromachining techniques, using superconducting transition, edge sensors as the thermistors. We describe the development of this multiplexed superconducting bolometer array architecture as a step toward bringing about the first astronomically useful arrays of this design. This technology will be used in the SAFIRE instrument on SOFIA, and is a candidate for a wide variety of other spectroscopic and photometric instruments.
引用
收藏
页码:1909 / 1916
页数:8
相关论文
共 14 条
[1]  
BANFORD DJ, 2000, IN PRESS P 11 INT S
[2]   Silicon nitride micromesh bolometer arrays for SPIRE [J].
Bock, JJ ;
Glenn, J ;
Grannan, SM ;
Irwin, KD ;
Lange, AE ;
LeDuc, HG ;
Turner, AD .
ADVANCED TECHNOLOGY MMW, RADIO, AND TERAHERTZ TELESCOPES, 1998, 3357 :297-304
[3]   Superconducting multiplexer for arrays of transition edge sensors [J].
Chervenak, JA ;
Irwin, KD ;
Grossman, EN ;
Martinis, JM ;
Reintsema, CD ;
Huber, ME .
APPLIED PHYSICS LETTERS, 1999, 74 (26) :4043-4045
[4]  
HARGRAVE PC, 1999, IN PRESS P LOW TEMP, V8
[5]   100 mK bolometers for the submillimetre common-user bolometer array (SCUBA) .1. Design and construction [J].
Holland, WS ;
Ade, PAR ;
Griffin, MJ ;
Hepburn, ID ;
Vickers, DG ;
Cunningham, CR ;
Hastings, PR ;
Gear, WK ;
Duncan, WD ;
Baillie, TEC ;
Haller, EE ;
Beeman, JW .
INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 1996, 17 (04) :669-692
[6]   A Mo-Cu superconducting transition-edge microcalorimeter with 4.5 eV energy resolution at 6 keV [J].
Irwin, KD ;
Hilton, GC ;
Martinis, JM ;
Deiker, S ;
Bergren, N ;
Nam, SW ;
Rudman, DA ;
Wollman, DA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 444 (1-2) :184-187
[7]   AN APPLICATION OF ELECTROTHERMAL FEEDBACK FOR HIGH-RESOLUTION CRYOGENIC PARTICLE-DETECTION [J].
IRWIN, KD .
APPLIED PHYSICS LETTERS, 1995, 66 (15) :1998-2000
[8]   Thermal-response time of superconducting transition-edge microcalorimeters [J].
Irwin, KD ;
Hilton, GC ;
Wollman, DA ;
Martinis, JM .
JOURNAL OF APPLIED PHYSICS, 1998, 83 (08) :3978-3985
[9]   Bolometer array development at the Max-Planck Institut fur Radioastronomie [J].
Kreysa, E ;
Gemund, HP ;
Gromke, J ;
Haslam, CGT ;
Reichertz, L ;
Haller, EE ;
Beeman, JW ;
Hansen, V ;
Sievers, A ;
Zylka, R .
ADVANCED TECHNOLOGY MMW, RADIO, AND TERAHERTZ TELESCOPES, 1998, 3357 :319-325
[10]   A MEDIUM RESOLUTION GROUND-BASED SUBMILLIMETER SPECTROMETER [J].
MAFFEI, B ;
PAJOT, F ;
PHILLIPS, TG ;
BENFORD, D ;
CAUX, E ;
GISPERT, R ;
HALVERSON, N ;
HUNTER, T ;
JEGOUDEZ, G ;
JOSSE, M ;
LAMARRE, JM ;
LEPELTIER, JP ;
MOSELEY, H ;
ORIGNE, A ;
PETUCHOWSKY, S ;
RABOTTIN, M ;
RENAULT, JC ;
RIOUX, C ;
SERABYN, G ;
WANG, N .
INFRARED PHYSICS & TECHNOLOGY, 1994, 35 (2-3) :321-329