Static strength of molar region direct technique glass fibre-reinforced composite fixed partial dentures

被引:16
作者
Dyer, SR
Lassila, LVJ
Alander, P
Vallittu, PK
机构
[1] Oregon Hlth & Sci Univ, Sch Dent, Dept Restorat Dent, Div Prosthodont,Div Biomat & Biomech, Portland, OR 97070 USA
[2] Turku Univ, Inst Dent, Dept Prosthet Dent & Biomat Res, Turku, Finland
关键词
composite; fibre; fibre-reinforced composite; fracture; fixed partial denture; retainer; initial failure; final failure;
D O I
10.1111/j.1365-2842.2004.01426.x
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
The aim of this study was to determine static fracture force of fibre-reinforced composite (FRC) fixed partial dentures (FPD) with different retainer designs. The fabrication simulated the process to make directly made 3-unit maxillary molar FPD. Four types of retainers were tested (n = 5): conventional crown preparation (1.2 mm axially and 2.0 mm occlusally), slot preparation (3.5 mm high x 3.5 mm wide x 1 mm deep), no preparation with broad fibre abutment contact, and combination of the slot and broad fibre contact were performed. The FPD contained unidirectional E-glass FRC veneered with particulate reinforced composite. Dimensions of the FPDs were homogenized. FPDs were stored at 1 week 37 degrees C deionized water, thermocycled between 5 degrees C and 55 degrees C (5000 cycles, dwell time 10 s) and statically loaded to failure. The slot retainer design yielded the lowest mean load to initial and final failure (FF) (1284 and 1313 N, respectively), the crown retainer the highest mean load to initial failure at 1755 N, and the combination retainer resulted in the highest mean load to FF (1836 N) (ANOVA, P < 0.001; Tukey multiple comparisons, 0.05 significance level). The results of this study suggest that the fabrication of direct FRC FPD does not necessarily require extensive preparation for the retainers.
引用
收藏
页码:351 / 357
页数:7
相关论文
共 32 条
[1]
Ahlstrand WM, 2002, QUINTESSENCE INT, V33, P359
[2]
LONGITUDINAL CLINICAL-EVALUATION OF FIBER-REINFORCED COMPOSITE FIXED PARTIAL DENTURES - A PILOT-STUDY [J].
ALTIERI, JV ;
BURSTONE, CJ ;
GOLDBERG, AJ ;
PATEL, AP .
JOURNAL OF PROSTHETIC DENTISTRY, 1994, 71 (01) :16-22
[3]
BARBERO EJ, 1998, INTRO COMPOSITE MAT, P2
[4]
Flexural properties of fiber reinforced composite using a vacuum/pressure or a manual adaptation manufacturing process [J].
Behr, M ;
Rosentritt, M ;
Lang, R ;
Handel, G .
JOURNAL OF DENTISTRY, 2000, 28 (07) :509-514
[5]
Cheng Y Y, 1999, J Prosthodont, V8, P268, DOI 10.1111/j.1532-849X.1999.tb00050.x
[6]
A 7-1/2 YEAR SURVIVAL STUDY OF RESIN-BONDED BRIDGES [J].
CREUGERS, NHJ ;
KAYSER, AF ;
VANTHOF, MA .
JOURNAL OF DENTAL RESEARCH, 1992, 71 (11) :1822-1825
[7]
Long-term survival data from a clinical trial on resin-bonded bridges [J].
Creugers, NHJ ;
DeKanter, RJAM ;
vantHof, MA .
JOURNAL OF DENTISTRY, 1997, 25 (3-4) :239-242
[8]
A five-year multi-practice clinical study on posterior resin-bonded bridges [J].
De Kanter, RJAM ;
Creugers, NHJ ;
Verzijden, CWGJM ;
Van't Hof, MA .
JOURNAL OF DENTAL RESEARCH, 1998, 77 (04) :609-614
[9]
THE EFFECT OF CARBON-FIBER ORIENTATION ON THE FATIGUE RESISTANCE AND BENDING PROPERTIES OF 2 DENTURE RESINS [J].
DEBOER, J ;
VERMILYEA, SG ;
BRADY, RE .
JOURNAL OF PROSTHETIC DENTISTRY, 1984, 51 (01) :119-121
[10]
Edelhoff D, 2001, QUINTESSENCE INT, V32, P269