Magnetic field-assisted DNA hybridisation and simultaneous detection using micron-sized spin-valve sensors and magnetic nanoparticles

被引:73
作者
Graham, DL
Ferreira, HA
Feliciano, N
Freitas, PP
Clarke, LA
Amaral, MD
机构
[1] Inst Engn Syst & Comp Microsyst & Nanotechnol, P-1000 Lisbon, Portugal
[2] Inst Super Tecn, Dept Phys, P-1000 Lisbon, Portugal
[3] Univ Lisbon, Dept Chem & Biochem, Fac Sci, P-1699 Lisbon, Portugal
[4] Natl Inst Hlth, Ctr Human Genet, Lisbon, Portugal
关键词
magnetoresistive biochip; DNA chip; spin-valve; magnetic nanoparticle;
D O I
10.1016/j.snb.2004.12.071
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Specifically designed on-chip microfabricated current-carrying metallic lines were used to generate local magnetic field gradients to facilitate the rapid focusing and hybridisation of magnetically labelled target DNA with complementary sensor-surface-bound probe DNA. Magnetoresistive biochips featuring high sensitivity spin valve sensors (2 μ m x 6 μ m) integrated within aluminium current lines. tapered in diameter from 150 to 5 μ m at each sensor location, were surface functionalized with probe DNA and interrogated with 250 nm magnetic nanoparticles functionalized with complementary or non-complementary target DNA, Currents of 20 mA were used to rapidly concentrate and manipulate the magnetic nanoparticles at sensor sites in minutes. overcoming the diffusion limited transport of target DNA that leads to long hybridisation times. On-chip target DNA concentrations between ∼ 10 and 200 pM resulted in magnetoresistive hybridisation signals of ∼ 1-2 mV at 8 mA sense current, equivalent to ∼ 50-100 sensor-bound nanoparticles. The noise level (∼ 20 μ V) was lit the level of a signal calculated for a single nanoparticle (18.8 μ V). Each nanoparticle was functionalized with < 500 DNA molecules with an estimated 70 DNA-DNA interactions per nanoparticle at the sensor surface. The detection range was ∼ 140-14,000 DNA molecules per sensor equivalent to ∼ 2-200 fmole/cm(2). No binding signals were observed for magnetically labelled non-complementary target DNA, © 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:936 / 944
页数:9
相关论文
共 24 条
[1]   A biosensor based on magnetoresistance technology [J].
Baselt, DR ;
Lee, GU ;
Natesan, M ;
Metzger, SW ;
Sheehan, PE ;
Colton, RJ .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (7-8) :731-739
[2]   Detection of a single magnetic microbead using a miniaturized silicon Hall sensor [J].
Besse, PA ;
Boero, G ;
Demierre, M ;
Pott, V ;
Popovic, R .
APPLIED PHYSICS LETTERS, 2002, 80 (22) :4199-4201
[3]   Cystic fibrosis: A worldwide analysis of CFTR mutations - Correlation with incidence data and application to screening [J].
Bobadilla, JL ;
Macek, M ;
Fine, JP ;
Farrell, PM .
HUMAN MUTATION, 2002, 19 (06) :575-606
[4]   PREDICTING DNA DUPLEX STABILITY FROM THE BASE SEQUENCE [J].
BRESLAUER, KJ ;
FRANK, R ;
BLOCKER, H ;
MARKY, LA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1986, 83 (11) :3746-3750
[5]   CYSTIC-FIBROSIS - MOLECULAR-BIOLOGY AND THERAPEUTIC IMPLICATIONS [J].
COLLINS, FS .
SCIENCE, 1992, 256 (5058) :774-779
[6]   Manipulation of magnetic microbeads in suspension using micromagnetic systems fabricated with soft lithography [J].
Deng, T ;
Whitesides, GM ;
Radhakrishnan, M ;
Zabow, G ;
Prentiss, M .
APPLIED PHYSICS LETTERS, 2001, 78 (12) :1775-1777
[7]   Planar Hall effect sensor for magnetic micro- and nanobead detection [J].
Ejsing, L ;
Hansen, MF ;
Menon, AK ;
Ferreira, HA ;
Graham, DL ;
Freitas, PP .
APPLIED PHYSICS LETTERS, 2004, 84 (23) :4729-4731
[8]   Biodetection using magnetically labeled biomolecules and arrays of spin valve sensors (invited) [J].
Ferreira, HA ;
Graham, DL ;
Freitas, PP ;
Cabral, JMS .
JOURNAL OF APPLIED PHYSICS, 2003, 93 (10) :7281-7286
[9]   Spin valve sensors [J].
Freitas, PP ;
Silva, F ;
Oliveira, NJ ;
Melo, LV ;
Costa, L ;
Almeida, N .
SENSORS AND ACTUATORS A-PHYSICAL, 2000, 81 (1-3) :2-8
[10]  
FREITAS PP, 2004, CABRAL MAGNETORESIST, P331