Digital radiology using active matrix readout of amorphous selenium: Geometrical and effective fill factors

被引:34
作者
Pang, G [1 ]
Zhao, W [1 ]
Rowlands, JA [1 ]
机构
[1] Univ Toronto, Sunnybrook Hlth Sci Ctr, Dept Med Biophys, Toronto, ON M4N 3M5, Canada
关键词
diagnostic x-ray imaging; digital radiology; amorphous selenium; solid-state imagers; flat panel imagers; geometrical fill factor; effective fill factor;
D O I
10.1118/1.598344
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Flat panel self-scanned x-ray detectors using amorphous selenium (a-Se) as the photoconductor are being developed to replace both film/screen cassette systems for radiography and image intensifier (XRII)/video systems for fluoroscopy. These use a two-dimensional array of pixel electrodes to collect and readout the latent image charges formed on the photoconductor surface. The percentage of the area covered by the pixel electrodes (i.e., the geometrical fill factor f(g)) is always less than unity. In this paper, a novel approach is introduced to make the charge collection by pixel electrodes almost complete (i.e., a close to unity effective fill factor). The idea is to bend the electric field lines in the a-Se layer in such a way that image charges cannot land in the gap region between electrodes. This is achieved by depositing holes in the gap region, which is possible because there are charge traps available at the a-Se/insulator interface. The distribution of holes required in the gap region is calculated. Various factors associated with the feasibility of this approach as well as a method to deposit these holes are discussed. Application of the approach to the case of mammography is also included. (C) 1998 American Association of Physicists in Medicine.
引用
收藏
页码:1636 / 1646
页数:11
相关论文
共 21 条
[1]  
ANDOH F, 1990, P IEEE INT SOL STAT, P212
[2]  
ANTONUK LE, 1992, P SOC PHOTO-OPT INS, V1651, P94, DOI 10.1117/12.59387
[3]   XERORADIOGRAPHY [J].
BOAG, JW .
PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (01) :3-37
[4]   Degradation of the detective quantum efficiency due to a non-unity detector fill factor [J].
Cunningham, IA .
PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 :22-31
[5]  
LEE DL, 1995, P SOC PHOTO-OPT INS, V2432, P237, DOI 10.1117/12.208342
[6]   A discussion on resolution and dynamic range of Se-TFT direct digital radiographic detector [J].
Lee, DL ;
Cheung, LK ;
Palecki, EF ;
Jeromin, LS .
PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 :511-522
[7]   Feasibility of a large area x-ray sensitive vidicon for medical fluoroscopy: Resolution and lag factors [J].
Luhta, R ;
Rowlands, JA .
MEDICAL PHYSICS, 1997, 24 (05) :621-631
[8]   Feasibility of a large area x-ray sensitive vidicon for medical fluoroscopy: Signal and noise factors [J].
Luhta, R ;
Rowlands, JA .
MEDICAL PHYSICS, 1997, 24 (05) :609-620
[9]   X-RAY-IMAGING USING AMORPHOUS SELENIUM - INHERENT SPATIAL-RESOLUTION [J].
QUE, W ;
ROWLANDS, JA .
MEDICAL PHYSICS, 1995, 22 (04) :365-374
[10]   X-ray imaging using amorphous selenium: Photoinduced discharge (PID) readout for digital general radiography [J].
Rowlands, JA ;
Hunter, DM .
MEDICAL PHYSICS, 1995, 22 (12) :1983-1996