Light-induced bone cement-philic titanium surface

被引:9
作者
Aita, Hideki [1 ]
Oh, Won [1 ]
Kubo, Katsuhiko [1 ,2 ]
Tsukimura, Naoki [1 ]
Maeda, Hatsuhiko [2 ]
Ogawa, Takahiro [1 ]
机构
[1] Univ Calif Los Angeles, Sch Dent, Div Adv Prosthodont Biomat & Hosp Dent, Jane Jerry Weintraub Ctr Reconstruct Biotechnol, Los Angeles, CA 90095 USA
[2] Aichi Gakuin Univ, Sch Dent, Dept Pathol, Nagoya, Aichi 464, Japan
关键词
D O I
10.1007/s10853-007-2353-8
中图分类号
T [工业技术];
学科分类号
08 [工学];
摘要
The survival of cemented endosseous implants can be improved by enhancing the bond between the implant and the cement. We hypothesized that the light-inducible generation of super-hydrophilicity of titanium positively affects its bone cement-philicity and bone cement-titanium bonding. Commercially pure titanium disks with machined surface and acid-etched micro roughened surfaces were prepared. Ultra-violet (UV) light treatment (0.1 mW/cm(2) UVA and 0.03 mW/cm(2) UVB for 48 h) created a super-hydrophilic surface for both surface types. The area of poly-methyl methacrylate (PMMA)-based bone cement spread increased by 30% and 20% on the light-treated machined titanium and acid-etched titanium surfaces, respectively, compared to the matched untreated ones. The contact angle of the bone cement decreased significantly after the light treatment, confirming the enhanced wettability of bone cement by the light treatment. Interfacial tensile stress between the bone cement material and titanium was increased 100% for the machined surface and 50% for the acid-etched surface by light treatment. Interfacial shear stress measured by a push-out test of titanium rods also revealed a 40% increase for the machined surface and 25% increase for the acid-etched surface. In conclusion, the pre-UV light treatment of titanium enhances the wettability and bonding strength of poly-methyl-methacrylate-based bone cement.
引用
收藏
页码:1552 / 1558
页数:7
相关论文
共 48 条
[1]
The natural history of debonding of the femoral component from the cement and its effect on long-term survival of charnley total hip replacements [J].
Berry, DJ ;
Harmsen, WS ;
Ilstrup, DM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (05) :715-721
[2]
Chen PC, 1998, CLIN ORTHOP RELAT R, P229
[3]
Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement - An average ten-year follow-up study [J].
Clohisy, JC ;
Harris, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (02) :247-255
[4]
D'Lima DD, 1998, CLIN ORTHOP RELAT R, P140
[5]
Davies Jeffrey P., 1993, Clinical Materials, V12, P121, DOI 10.1016/0267-6605(93)90061-B
[6]
THE EFFECT OF A THIN COATING OF POLYMETHYLMETHACRYLATE ON THE TORSIONAL FATIGUE-STRENGTH OF THE CEMENT METAL INTERFACE [J].
DAVIES, JP ;
SINGER, G ;
HARRIS, WH .
JOURNAL OF APPLIED BIOMATERIALS, 1992, 3 (01) :45-49
[7]
Fischer H, 2001, J BIOMED MATER RES, V57, P413, DOI 10.1002/1097-4636(20011205)57:3<413::AID-JBM1184>3.0.CO
[8]
2-R
[9]
FOWLER JL, 1988, ORTHOP CLIN N AM, V19, P477
[10]
FAILURE OF THE CEMENT-BONE INTERFACE - A CONSEQUENCE OF STRENGTHENING THE CEMENT-PROSTHESIS INTERFACE [J].
GARDINER, RC ;
HOZACK, WJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (01) :49-52