Determination of some trace heavy metals in some water samples by FAAS after their preconcentration using DETA

被引:11
作者
Bakircioglu, Y
Akman, S [1 ]
Biçak, N
Senkal, F
机构
[1] Istanbul Tech Univ, Dept Chem, TR-80626 Istanbul, Turkey
[2] Trakya Univ, Dept Chem, Edirne, Turkey
来源
JOURNAL OF TRACE AND MICROPROBE TECHNIQUES | 2003年 / 21卷 / 02期
关键词
diethylenetriamine; preconcentration; Co; Mn; Ni; atomic absorption spectrometry;
D O I
10.1081/TMA-120020259
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Diethylenetriamine, DETA polymer was used as a preconcentration of cobalt, iron and nickel prior to their determination by flame atomic. ab-sorption spectrometry (FAAS). Both batch-and column methods were used for the separation and concentration of above metals. These metals were quantitatively retained on the proposed adsorbent at pH 21 then were quantitatively eluted with 2 M hydrochloric acid or nitric acid. The recoveries of metal ions were greater than 98%. Detection limits (3 delta) were 1.5 g/L for Co, 2 . I g/L for Fe and 1.9 g/L for Ni. The relative standard deviations for the determinations were found to be 1.0-8.8%. The effect of Na on the preconcentration of trace metals has also been investigated. The method was applied to tap, ground and lake water samples.
引用
收藏
页码:239 / 248
页数:10
相关论文
共 30 条
[1]   INVESTIGATION ON THE PRECONCENTRATION OF TRACE-ELEMENTS ON POLYACRYLONITRILE [J].
ARIK, N ;
TURKER, AR .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 339 (12) :874-876
[2]   Solid phase extraction of some metal ions on Diaion-20 resin prior to flame atomic absorption spectrometric analysis [J].
Armagan, F ;
Soylak, M ;
Elci, L ;
Dogan, M .
JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 2002, 20 (01) :15-27
[3]   Determination of cadmium, copper, and zinc by flame atomic absorption spectrometry after preconcentration using a DETA (diethylenetriamine) polymer [J].
Bakircioglu, Y ;
Seren, G ;
Akman, S .
ANALYTICAL LETTERS, 2001, 34 (03) :439-447
[4]   Concentration of cadmium, copper and zinc using water soluble polyacrylic acid polymer [J].
Bakircioglu, Y ;
Seren, G ;
Akman, S .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (07) :1129-1133
[5]  
Bicak N, 1997, J POLYM SCI POL CHEM, V35, P2857
[6]   Determination of Cd, Co, Cu, Mn, Ni, Pb, and Zn by inductively coupled plasma mass spectroscopy or flame atomic absorption spectrometry after on-line preconcentration and solvent extraction by flow injection system [J].
Bortoli, A ;
Gerotto, M ;
Marchiori, M ;
Mariconti, F ;
Palonta, M ;
Troncon, A .
MICROCHEMICAL JOURNAL, 1996, 54 (04) :402-411
[7]   CELLULOSE TETPA - A CHELATING COLLECTOR DESIGNED FOR MULTIELEMENT PRECONCENTRATION IN FLOW SYSTEMS [J].
BURBA, P ;
ROCHA, JC ;
SCHULTE, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (04) :414-419
[8]   Flow injection solid phase extraction with Chromosorb 102:: determination of lead in soil and waters by flame atomic absorption spectrometry [J].
Elçi, L ;
Arslan, Z ;
Tyson, JF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (07) :1109-1116
[9]   REMOVAL OF W-185, MO-99 AND SB-125 RADIOISOTOPES FROM AQUEOUS-SOLUTIONS USING POLYAMINE INCORPORATED POLYSACCHARIDES [J].
GUPTA, SC ;
TAK, BB ;
MATHUR, NK ;
NARANG, CK .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1993, 170 (01) :3-8
[10]  
HONGNIAN J, 1998, FRESEN J ANAL CHEM, V360, P721