In-source CID mass spectral libraries for the "general unknown" screening of drugs and toxicants

被引:69
作者
Marquet, P [1 ]
Venisse, N
Lacassie, É
Lachâtre, G
机构
[1] Univ Hosp, Dept Pharmacol & Toxicol, Limoges, France
[2] Univ Limoges, Fac Pharm, Toxicol Lab, Limoges, France
关键词
D O I
10.1051/analusis:2000280925
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A "general unknown" screening procedure for drugs and toxicants using LC-ES-MS was developed. It involved in-source collision induced dissociation of the molecular ions (in the negative-ion mode) or protonated molecules (in the positive-ion mode) generally obtained from electrospray sources. Spectra were reconstructed by adding, on one hand, a pair of positive spectra, one without and one with fragmentation, and on the other a pair of negative spectra acquired in similar conditions. These reconstructed spectra showed at least as many fragments as MS/MS spectra, and sometimes as many as electron-ionisation spectra. They were repeatable and reproducible enough to be used for the specific identification of hundreds of molecules. Libraries of about 1100 positive spectra and 500 negative spectra were constructed and are used routinely, together with chromatographic separation involving a Nucleosil C18, 5 mum column (150 x 1 mm i.d.) and a gradient of acetonitrile in 2 mM, pH 3 ammonium formate as a screening technique complementary to GC-MS and HPLC-DAD.
引用
收藏
页码:925 / 934A
页数:10
相关论文
共 13 条
[1]  
Baumann C, 2000, RAPID COMMUN MASS SP, V14, P349, DOI 10.1002/(SICI)1097-0231(20000315)14:5<349::AID-RCM873>3.3.CO
[2]  
2-G
[3]   Poor reproducibility of in-source collisional atmospheric pressure ionization mass spectra of toxicologically relevant drugs [J].
Bogusz, MJ ;
Maier, RD ;
Krüger, KD ;
Webb, KS ;
Romeril, J ;
Miller, ML .
JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) :409-418
[4]   Evaluation of electrospray transport CID for the generation of searchable libraries [J].
Hough, JM ;
Haney, CA ;
Voyksner, RD ;
Bereman, RD .
ANALYTICAL CHEMISTRY, 2000, 72 (10) :2265-2270
[5]   SCOPE AND LIMITATIONS OF A GENERAL UNKNOWN SCREENING BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY IN ACUTE-POISONING [J].
KOPPEL, C ;
TENCZER, J .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (11) :995-1003
[6]   Liquid chromatography-mass spectrometry:: potential in forensic and clinical toxicology [J].
Marquet, P ;
Lachâtre, G .
JOURNAL OF CHROMATOGRAPHY B, 1999, 733 (1-2) :93-118
[7]  
MARQUET P, 1998, M AM SOC MASS SPECTR
[8]   Analysis of antibiotics by liquid chromatography mass spectrometry [J].
Niessen, WMA .
JOURNAL OF CHROMATOGRAPHY A, 1998, 812 (1-2) :53-75
[9]  
PFLEGER K, 1992, MASS SPECTRAL GC DAT
[10]   Application of spectral libraries for high-performance liquid chromatography-atmospheric pressure ionisation mass spectrometry to the analysis of pesticide and explosive residues in environmental samples [J].
Schreiber, A ;
Efer, J ;
Engewald, W .
JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) :411-425