Effect of Dentin Wetness on the Bond Strength of Universal Adhesives

被引:55
作者
Choi, An-Na [1 ]
Lee, Ji-Hye [2 ,3 ]
Son, Sung-Ae [1 ]
Jung, Kyoung-Hwa [1 ]
Kwon, Yong Hoon [4 ]
Park, Jeong-Kil [1 ]
机构
[1] Pusan Natl Univ, Dent Res Inst, Sch Dent, Dept Conservat Dent, Yangsan 50612, South Korea
[2] Pusan Natl Univ, Inst Translat Dent Sci, Sch Dent, Dept Oral Pathol, Yangsan 50612, South Korea
[3] Pusan Natl Univ, Inst Translat Dent Sci, Sch Dent, PLUS Project BK21, Yangsan 50612, South Korea
[4] Pusan Natl Univ, Sch Dent, Dept Dent Mat, Yangsan 50612, South Korea
关键词
bonding; adhesive resins; dentin; micro-tensile strength; confocal laser scanning microscopy; SELF-ETCHING ADHESIVES; MULTIMODE ADHESIVE; WATER STORAGE; HYBRID LAYER; DRY DENTIN; RESIN; SOLVENT; ENAMEL; WET; PERMEABILITY;
D O I
10.3390/ma10111224
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070305 [高分子化学与物理];
摘要
The effects of dentin wetness on the bond strength and adhesive interface morphology of universal adhesives have been investigated using micro-tensile bond strength (TBS) testing and confocal laser scanning microscopy (CLSM). Seventy-two human third molars were wet ground to expose flat dentin surfaces. They were divided into three groups according to the air-drying time of the dentin surfaces: 0 (without air drying), 5, and 10 s. The dentin surfaces were then treated with three universal adhesives: G-Premio Bond, Single Bond Universal, and All-Bond Universal in self-etch or etch-and-rinse mode. After composite build up, a TBS test was performed. One additional tooth was prepared for each group by staining the adhesives with 0.01 wt % of Rhodamine B fluorescent dye for CLSM analysis. The data were analyzed statistically using ANOVA and Tukey's post hoc tests ( = 0.05). Two-way ANOVA showed significant differences among the adhesive systems and dentin moisture conditions. An interaction effect was also observed (p < 0.05). One-way ANOVA showed that All-Bond Universal was the only material influenced by the wetness of the dentin surfaces. Wetness of the dentin surface is a factor influencing the micro-tensile bond strength of universal adhesives.
引用
收藏
页数:13
相关论文
共 47 条
[1]
Alex Gary, 2015, Compend Contin Educ Dent, V36, P15
[2]
The influence of water storage and C-factor on the dentin-resin composite microtensile bond strength and debond pathway utilizing a filled and unfilled adhesive resin [J].
Armstrong, SR ;
Keller, JC ;
Boyer, DB .
DENTAL MATERIALS, 2001, 17 (03) :268-276
[3]
Asmussen E, 2001, J Adhes Dent, V3, P123
[4]
Dental adhesion review: Aging and stability of the bonded interface [J].
Breschi, Loyenzo ;
Mazzoni, Annalisa ;
Ruggeri, Alessandra ;
Cadenaro, Milena ;
Di Lenarda, Robeyto ;
Dorigo, Elettya De Stefano .
DENTAL MATERIALS, 2008, 24 (01) :90-101
[5]
Cardoso PC, 2005, OPER DENT, V30, P376
[6]
Effect of water storage on the bonding effectiveness of 6 adhesives to class I cavity dentin [J].
De Munck, J. ;
Shirai, K. ;
Yoshida, Y. ;
Inoue, S. ;
Van Landuyt, K. L. ;
Lambrechts, P. ;
Suzuki, K. ;
Shintani, H. ;
Van Meerbeek, B. .
OPERATIVE DENTISTRY, 2006, 31 (04) :456-465
[7]
Performance of a New One-step Multi-mode Adhesive on Etched vs Non-etched Enamel on Bond Strength and Interfacial Morphology [J].
Fernando de Goes, Mario ;
Shinohara, Mirela Sanae ;
Freitas, Marcela Santiago .
JOURNAL OF ADHESIVE DENTISTRY, 2014, 16 (03) :243-250
[8]
Ferracane JL, 1998, J BIOMED MATER RES, V42, P465, DOI 10.1002/(SICI)1097-4636(19981205)42:3<465::AID-JBM17>3.3.CO
[9]
2-T
[10]
Finger W J, 1999, J Adhes Dent, V1, P311