Intraoperative arrhythmias and tissue damage during transmyocardial laser revascularization

被引:16
作者
Kadipasaoglu, KA
Sartori, M
Masai, T
Cihan, HB
Clubb, FJ
Conger, JL
Frazier, OH
机构
[1] St Lukes Episcopal Hosp, Texas Heart Inst, Cullen Cardiovasc Res Labs, Houston, TX USA
[2] St Lukes Episcopal Hosp, Texas Heart Inst, Dept Adult Cardiol, Houston, TX USA
[3] St Lukes Episcopal Hosp, Texas Heart Inst, Dept Cardiovasc Pathol, Houston, TX USA
[4] St Lukes Episcopal Hosp, Texas Heart Inst, Dept Cardiovasc Surg, Houston, TX USA
关键词
D O I
10.1016/S0003-4975(98)01135-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Transmyocardial laser revascularization creates transmural channels to improve myocardial perfusion. Different laser sources and ablation modalities have been proposed for transmyocardial laser revascularization. We investigated the incidence of cardiac arrhythmias and laser-tissue interactions during transmyocardial laser revascularization of normal porcine myocardium with three different lasers. Methods. We used a continuous-wave, chopped CO2 laser (20 J/pulse, 15 s/pulse) synchronized with the R wave; a holmium:yttrium aluminum garnet (:Ho:Y(AG) laser (2 J/pulse, 250 mu s/pulse, 5 Hz); and a xenon-chloride (excimer, Xe:CI) laser (35 mJ/pulse, 20 ns/pulse, 30 Hz). Each laser was used 30 times as the sole modality in four consecutive pigs, yielding 120 channels. Results. The average number of pulses needed to create a channel was 1, 11 +/- 4,and 37 +/- 8 for the CO2 Ho:YAG, and Xe:CI lasers, respectively. All Ho:YAG and Xe:CI channels had premature ventricular contractions Ventricular tachycardia occurred in 70% of the Xe:CI and 60% of the Ho:YAG channels. Only 36% of the CO2 channels had premature ventricular contractions, and only 3% of the CO2 channels had ventricular tachycardia (p < 0.001 versus Ho:YAG and Xe:CI). Ho:YAG channels were highly irregular: each had a 0.6-mm-wide central zone surrounded by a ring of coagulation necrosis (diameter, 1.84 +/- 0.67 mm) with effaced cellular architecture in a thin hemorrhagic zone. The Xe:Cl sections exhibited the same patterns on a smaller scale (diameter, 0.74 +/- 0.18 mm). The CO, channels were straight and well demarcated. The zone of structural and thermal damage extended over half the channel's diameter, measuring 0.52 +/- 0.25 mm. Conclusions. During transmyocardial laser revascularization, the CO2 laser synchronized with the R wave is significantly less arrhythmogenic than the Ho:YAG and Xe:CI lasers not synchronized with the R wave. In addition, the interaction of the CO2 laser with porcine cardiac tissue is significantly less traumatic than that of the Ho:YAG and the Xe:Cl lasers. (C) 1999 by The Society of Thoracic Surgeons.
引用
收藏
页码:423 / 431
页数:9
相关论文
共 18 条
[11]  
Kadipasaoglu K. A., 1992, Lasers in the Life Sciences, V5, P95
[12]   INDUCTION OF FUNCTIONAL CORONARY COLLATERALS IN THE SWINE HEART [J].
MILLARD, RW .
BASIC RESEARCH IN CARDIOLOGY, 1981, 76 (05) :468-473
[13]  
MIRHOSEINI M, 1982, Lasers in Surgery and Medicine, V2, P187, DOI 10.1002/lsm.1900020209
[14]   Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia [J].
Moss, AJ ;
Hall, WJ ;
Cannom, DS ;
Daubert, JP ;
Higgins, SL ;
Klein, H ;
Levine, JH ;
Saksena, S ;
Waldo, AL ;
Wilber, D ;
Brown, MW ;
Heo, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 335 (26) :1933-1940
[15]   MYOCARDIAL REVASCULARIZATION BY TRANSMYOCARDIAL ACUPUNCTURE - A PHYSIOLOGIC IMPOSSIBILITY [J].
PIFARRE, R ;
JASUJA, ML ;
LYNCH, RD ;
NEVILLE, WE .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1969, 58 (03) :424-&
[16]  
RASTEGAR S, 1990, LASERS SURG MED S, V2, pA62
[17]   CORONARY COLLATERAL CIRCULATION IN THE PIG - CORRELATION OF COLLATERAL FLOW WITH CORONARY BED SIZE [J].
WHITE, FC ;
BLOOR, CM .
BASIC RESEARCH IN CARDIOLOGY, 1981, 76 (02) :189-196
[18]  
WHITE FC, 1986, LAB ANIM SCI, V36, P351