In vivo MR imaging and spectroscopy using hyperpolarized Xe-129

被引:123
作者
Wagshul, ME [1 ]
Button, TM [1 ]
Li, HFF [1 ]
Liang, ZR [1 ]
Springer, CS [1 ]
Zhong, K [1 ]
Wishnia, A [1 ]
机构
[1] SUNY STONY BROOK, DEPT CHEM, STONY BROOK, NY 11794 USA
关键词
hyperpolarized Xe-129; bulk magnetic susceptibility; in vivo Xe-129 spectroscopy; MRI of lung; MAGNETIC-RESONANCE; CHEMICAL-SHIFTS; GAS; NMR; LUNGS; SOLUBILITY; SOLVENTS;
D O I
10.1002/mrm.1910360203
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Hyperpolarized Xe-129 has been used to obtain gas phase images of mouse lung in vivo, showing distinct ventilation variation as a function of the breathing cycle. Spectra of Xe-129 in the thorax show complex structure in both the gas phase (-4 to 3 ppm) and tissue-dissolved (190-205 ppm) regions. The alveolar gas peak shows correlated intensity and frequency oscillations, both attributable to changes in lung volume during breathing. The two major dissolved peaks near 195-200 ppm are attributed to lung parenchyma and to blood; they reach maximum intensity in 5-10 s and decay with an apparent T-1 of 30 s. Another peak at 190 ppm takes 20-30 s to reach maximum; this must represent other well-vascularized tissue (e.g., heart and other muscles) in the thorax. The maximum integrated area of the tissue components reaches 30-80% of the maximum alveolar gas area, indicating that imaging at tissue frequencies can be achieved.
引用
收藏
页码:183 / 191
页数:9
相关论文
共 26 条
[1]   SOLUBILITY PROPERTIES IN POLYMERS AND BIOLOGICAL MEDIA .2. THE CORRELATION AND PREDICTION OF THE SOLUBILITIES OF NONELECTROLYTES IN BIOLOGICAL TISSUES AND FLUIDS [J].
ABRAHAM, MH ;
KAMLET, MJ ;
TAFT, RW ;
DOHERTY, RM ;
WEATHERSBY, PK .
JOURNAL OF MEDICINAL CHEMISTRY, 1985, 28 (07) :865-870
[2]   POTENTIAL INDUSTRIAL APPLICATIONS OF INHOMOGENEOUS BROADENING IMAGING [J].
AILION, DC .
MAGNETIC RESONANCE IMAGING, 1992, 10 (05) :799-808
[3]  
ALAVI A, 1977, Applied Radiology, V6, P182
[4]  
ALBERT MS, 1994, NATURE, V370, P199, DOI 10.1038/370199a0
[5]  
CHU SCK, 1990, MAGN RESON MED, V13, P239, DOI 10.1002/mrm.1910130207
[6]  
CROSFILL ML, 1961, J PHYSIOL-LONDON, V158, P1, DOI 10.1113/jphysiol.1961.sp006750
[7]   CALCULATION AND INTERPRETATION OF INHOMOGENEOUS LINE BROADENING IN MODELS OF LUNGS AND OTHER HETEROGENEOUS STRUCTURES [J].
DURNEY, CH ;
BERTOLINA, J ;
AILION, DC ;
CHRISTMAN, R ;
CUTILLO, AG ;
MORRIS, AH ;
HASHEMI, S .
JOURNAL OF MAGNETIC RESONANCE, 1989, 85 (03) :554-570
[8]   MR MICROSCOPY OF THE RAT LUNG USING PROJECTION RECONSTRUCTION [J].
GEWALT, SL ;
GLOVER, GH ;
HEDLUND, LW ;
COFER, GP ;
MACFALL, JR ;
JOHNSON, GA .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (01) :99-106
[9]  
[Gillies R.J. Springer CS. Springer CS.], 1994, NMR in Physiology and Biomedicine, P75
[10]   SNAPSHOT FLASH MRI - APPLICATIONS TO T1, T2, AND CHEMICAL-SHIFT IMAGING [J].
HAASE, A .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) :77-89