MR MICROSCOPY OF THE RAT LUNG USING PROJECTION RECONSTRUCTION

被引:93
作者
GEWALT, SL [1 ]
GLOVER, GH [1 ]
HEDLUND, LW [1 ]
COFER, GP [1 ]
MACFALL, JR [1 ]
JOHNSON, GA [1 ]
机构
[1] DUKE UNIV,MED CTR,DEPT RADIOL,BOX 3302,DURHAM,NC 27710
关键词
MR MICROSCOPY; LUNG; PROJECTION RECONSTRUCTION;
D O I
10.1002/mrm.1910290117
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Projection reconstruction has been implemented with self refocused selection pulses on a small bore, 2.0 T MR microscope, to allow imaging of lung parenchyma. Scan synchronous ventilation and cardiac gating have been integrated with the sequence to minimize motion artifacts. A systematic survey of the pulse sequence parameters has been undertaken in conjunction with the biological gating parameters to optimize resolution and signal-to-noise (SNR). The resulting projection images with effective echo time of <300 musec allow definition of lung parenchyma with an SNR improvement of approximately 15 x over a more conventional 2DFT short echo gradient sequence.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 28 条
  • [1] LUNG PARENCHYMA - MAGNETIC-SUSCEPTIBILITY IN MR IMAGING
    BERGIN, CJ
    GLOVER, GH
    PAULY, JM
    [J]. RADIOLOGY, 1991, 180 (03) : 845 - 848
  • [2] LUNG PARENCHYMA - PROJECTION RECONSTRUCTION MR-IMAGING
    BERGIN, CJ
    PAULY, JM
    MACOVSKI, A
    [J]. RADIOLOGY, 1991, 179 (03) : 777 - 781
  • [3] BURNEY CH, 1989, J MAGN RESON, V85, P554
  • [4] CHEMICAL-SHIFT ARTIFACT CORRECTION SCHEME USING ECHO-TIME ENCODING TECHNIQUE
    CHO, ZH
    NALCIOGLU, O
    PARK, HW
    RA, JB
    HILAL, SK
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1985, 2 (03) : 253 - 261
  • [5] SPIN WARP NMR IMAGING AND APPLICATIONS TO HUMAN WHOLE-BODY IMAGING
    EDELSTEIN, WA
    HUTCHISON, JMS
    JOHNSON, G
    REDPATH, T
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04) : 751 - 756
  • [6] GLOVER G, 1989, P SOC MAGN RESON AMS, P32
  • [7] THEORETICAL RESOLUTION OF COMPUTED TOMOGRAPHY SYSTEMS
    GLOVER, GH
    EISNER, RL
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (01) : 85 - 91
  • [8] RAPID DATA-ACQUISITION TECHNIQUE FOR NMR IMAGING BY THE PROJECTION RECONSTRUCTION METHOD
    HALL, LD
    SUKUMAR, S
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1984, 56 (01) : 179 - 182
  • [9] HEDLUND L, 1988, P SOC MAGN RESON MED, V2, P774
  • [10] A VENTILATOR FOR MAGNETIC-RESONANCE-IMAGING
    HEDLUND, LW
    DEITZ, J
    NASSAR, R
    HERFKENS, R
    VOCK, P
    DAHLKE, J
    KUBEK, R
    EFFMANN, EL
    PUTMAN, CE
    [J]. INVESTIGATIVE RADIOLOGY, 1986, 21 (01) : 18 - 23