Kinetic modeling of PET data without blood sampling

被引:18
作者
Bentourkia, M [1 ]
机构
[1] CHU Sherbrooke, Dept Med Nucl & Radiobiol, Sherbrooke, PQ J1H 5N4, Canada
关键词
acetate; ammonia; blood sampling; fluorodeoxyglucose (FDG); input curve; kinetic modeling; metabolism; perfusion; positron emission tomography (PET);
D O I
10.1109/TNS.2005.851442
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In positron emission tomography (PET) imaging, application of kinetic modeling always requires an input curve (IQ together with the PET data. The IC can be obtained by means of external blood sampling or, in the case of cardiac studies, by means of a region-of-interest (ROI) drawn on the blood pool. It is, however, very unsuitable to withdraw and to analyze blood samples, and in small animals, these operations become difficult, while ICs determined from ROIs are generally contaminated by emissions from neighboring sites, or they are underestimated because of partial volume effect. In this paper, we report a new method to extract kinetic parameters from dynamic PET studies without a priori knowledge of the IC. The method is applied in human brain data measured with fluorodeoxyglucose (FDG) human-brain and in cardiac-rat perfusion studies with N-13-ammonia and C-11-acetate. The tissue blood volume (TBV), usually fitted together with the rate constants, is extracted simultaneously with the tissue time activity curves for cardiac studies, while for brain gray matter, TBV is known to be about 4% to 7%. The shape of IC is obtained by means of factor analysis from an ROI drawn around a cardiac tissue or a brain artery. The results show a good correlation (p < 0.05) between the cerebral metabolic rate of glucose, myocardial blood flow, and oxygen consumption obtained with the new method in comparison to the usual method. In conclusion, it is possible to apply kinetic modeling without any blood sampling, which significantly simplifies PET acquisition and data analysis.
引用
收藏
页码:697 / 702
页数:6
相关论文
共 52 条
[1]  
Ahn JY, 2001, J NUCL MED, V42, P782
[2]   A standardized blood sampling scheme in quantitative FDG-PET studies [J].
Bentourkia, M ;
Bol, A ;
Ivanoiu, A ;
Michel, C ;
Coppens, A ;
Sibomana, M ;
Cosnard, G ;
De Volder, AG .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (05) :379-384
[3]   Cardiac studies in rats with 11C-acetate and PET:: A comparison with 13N-ammonia [J].
Bentourkia, M ;
Croteau, É ;
Langlois, R ;
Aliaga, A ;
Cadorette, J ;
Bénard, F ;
Lesur, O ;
Lecomte, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) :2322-2327
[4]   Comparison of regional cerebral blood flow and glucose metabolism in the normal brain: effect of aging [J].
Bentourkia, M ;
Bol, A ;
Ivanoiu, A ;
Labar, D ;
Sibomana, M ;
Coppens, A ;
Michel, C ;
Cosnard, G ;
De Volder, AG .
JOURNAL OF THE NEUROLOGICAL SCIENCES, 2000, 181 (1-2) :19-28
[5]  
Bentourkia M, 1999, IEEE NUCL SCI CONF R, P1124, DOI 10.1109/NSSMIC.1999.845857
[6]   Characteristics of a new fully programmable blood sampling device for monitoring blood radioactivity during PET [J].
Boellaard, R ;
van Lingen, A ;
van Balen, SCM ;
Hoving, BG ;
Lammertsma, AA .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (01) :81-89
[7]  
Bonson KR, 2000, J NUCL MED, V41, P658
[8]  
BUCK A, 1991, J NUCL MED, V32, P1950
[9]   THE EFFECTS OF MEASUREMENT ERRORS IN THE PLASMA RADIOACTIVITY CURVE ON PARAMETER-ESTIMATION IN POSITRON EMISSION TOMOGRAPHY [J].
CHEN, K ;
HUANG, SC ;
YU, DC .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (09) :1183-1200
[10]  
CHOI Y, 1991, J NUCL MED, V32, P733