High spatial resolution multi-site EPR oximetry - The use of a convolution-based fitting method

被引:31
作者
Grinberg, OY
Smirnov, AI
Swartz, HM
机构
[1] Dartmouth Coll Sch Med, Dept Radiol, EPR Ctr Study Viable Syst, Hanover, NH 03755 USA
[2] N Carolina State Univ, Dept Chem, Raleigh, NC 27695 USA
关键词
EPR oximetry; multi-site EPR oximetry; tissue pO(2); convolution-based fitting;
D O I
10.1006/jmre.2001.2408
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe a new method to enhance the spatial resolution of multi-site electron paramagnetic resonance (EPR) oximetry. The method is suitable for any shape (density distribution function) of a solid paramagnetic material implanted in tissue. It corrects distortions of lineshapes caused by the gradient and thus overcomes limitations of previous multi-site EPR oximetry methods that restricted the ratio of the particle size to the distance between site. The new method is based on consecutive applications of magnetic field gradients with the same direction but with a different magnitude and uses a convolution-based fitting algorithm to derive Lorentzian EPR linewidths of each individual peak of the EPR spectrum. The method is applicable for any particulate EPR oxygen sensitive materials whose EPR spectra can be approximated by a Lorentzian function or a superposition of Lorentzian functions. By incorporating this model of the lineshape in the data processing, we are able to decrease significantly the number of parameters needed for the calculations and to recover the oxygen concentration, even from quite noisy spectra. We (i) describe our method and the data-processing algorithm, (ii) demonstrate our approach in model and in vivo experiments, and (iii) discuss the limitations. (C) 2001 Academic Press.
引用
收藏
页码:247 / 258
页数:12
相关论文
共 27 条
[1]  
Bruley D. F., 1992, OXYGEN TRANSPORT TIS, P229
[2]   SIMULATION OF MULTIPLE ISOTROPIC SPIN-TRAP EPR-SPECTRA [J].
DULING, DR .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 104 (02) :105-110
[3]  
Ewert U., 1991, EPR IMAGING IN VIVO, P119
[4]   DIFFUSION OF FREE-RADICALS AS STUDIED BY TOMOGRAPHY [J].
GALTSEVA, EV ;
YAKIMCHENKO, OY ;
LEBEDEV, YS .
CHEMICAL PHYSICS LETTERS, 1983, 99 (04) :301-304
[5]  
GALTSEVA EV, 1984, SPATIAL DISTRIBUTION, P26
[6]  
Grinberg OY, 2001, KEIO UNIV SYMP LIFE, V6, P381
[7]  
GRINBERG OY, IN PRESS OXYGEN TRAN, V22
[8]   Electronically tunable surface-coil-type resonator for L-band EPR spectroscopy [J].
Hirata, H ;
Walczak, T ;
Swartz, HM .
JOURNAL OF MAGNETIC RESONANCE, 2000, 142 (01) :159-167
[9]   Gloxy: An oxygen-sensitive coal for accurate measurement of low oxygen tensions in biological systems [J].
James, PE ;
Grinberg, OY ;
Goda, F ;
Panz, T ;
OHara, JA ;
Swartz, HM .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (01) :48-58
[10]   ASSESSMENT OF CEREBRAL PO(2) BY EPR OXIMETRY IN RODENTS - EFFECTS OF ANESTHESIA, ISCHEMIA, AND BREATHING GAS [J].
LIU, KJ ;
BACIC, G ;
HOOPES, PJ ;
JIANG, JJ ;
DU, HK ;
OU, LC ;
DUNN, JF ;
SWARTZ, HM .
BRAIN RESEARCH, 1995, 685 (1-2) :91-98