摘要
Information is limited for the exposure levels of airborne hazardous substances in swine feed buildings that are not completely enclosed. Open-style breeding, growing and finishing swine houses in six farms in subtropical Taiwan were studied for the airborne concentrations of endotoxin, dust, ammonia, hydrogen sulfide and carbon dioxide. The air in the farrowing and nursery stalls as partially enclosed was also simultaneously evaluated. Three selected gases and airborne dusts were quantified respectively by using Drager diffusion tubes and a filter-weighing method. Endotoxin was analyzed by the Limulusamoebocyte lysate assay. Average concentration of airborne total endotoxin among piggeries was between 36.8 and 298 EU/m(3), while that for respirable endotoxin was 14.1-129 EU/m(3). Mean concentration of total dust was between 0.15 and 0.34 mg/m(3), with average level of respirable dust of 0.14 mg/m(3). The respective concentrations of NH3, CO2 and H2S were less than 5 ppm, 600-895 ppm and less than 0.2 ppm. Airborne concentrations of total dust and endotoxin in the nursery house were higher than in the other types of swine houses. The finishing house presented the highest exposure risk to NH3, CO2 and H2S. Employees working in the finishing stalls were also exposed to the highest airborne levels of respirable endotoxin and dust. On the other hand, the air of the breeding units was the least contaminated in terms of airborne endotoxin, dust, NH3, CO2 and H2S. The airborne concentrations of substances measured in the present study were all lower than most of published studies conducted in mainly enclosed swine buildings. Distinct characteristics, including maintaining swine houses in an open status and frequent spraying water inside the stalls, significantly reduce accumulation of gases and airborne particulates. (C) 2001 British Occupational Hygiene Society. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:457 / 465
页数:9
相关论文
共 28 条
  • [1] ATTWOOD P, 1987, AM IND HYG ASSOC J, V48, P745, DOI 10.1080/15298668791385507
  • [2] ASSESSMENT OF DUST AND ENDOTOXIN LEVELS IN THE WORKING ENVIRONMENT OF DUTCH PIG FARMERS - A PRELIMINARY-STUDY
    ATTWOOD, P
    VERSLOOT, P
    HEEDERIK, D
    DEWIT, R
    BOLEIJ, JSM
    [J]. ANNALS OF OCCUPATIONAL HYGIENE, 1986, 30 (02) : 201 - 208
  • [3] Exposure of workers to airborne microorganisms in open-air swine houses
    Chang, CW
    Chung, H
    Huang, CF
    Su, HJJ
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2001, 67 (01) : 155 - 161
  • [4] CLARK S, 1983, AM IND HYG ASSOC J, V44, P537, DOI 10.1080/15298668391405265
  • [5] CORMIER Y, 1990, AM IND HYG ASSOC J, V51, P304, DOI 10.1080/15298669091369709
  • [6] CROOK B, 1991, AM IND HYG ASSOC J, V52, P271, DOI 10.1080/15298669191364721
  • [7] DONHAM K, 1989, BRIT J IND MED, V46, P31
  • [8] Donham K.J., 1982, Annual American Conference of Governmental Industrial Hygienists, V2, P137
  • [9] DONHAM KJ, 1985, AM IND HYG ASSOC J, V46, P658, DOI 10.1080/15298668591395490
  • [10] RESPIRATORY DYSFUNCTION IN SWINE PRODUCTION FACILITY WORKERS - DOSE-RESPONSE RELATIONSHIPS OF ENVIRONMENTAL EXPOSURES AND PULMONARY-FUNCTION
    DONHAM, KJ
    REYNOLDS, SJ
    WHITTEN, P
    MERCHANT, JA
    BURMEISTER, L
    POPENDORF, WJ
    [J]. AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 1995, 27 (03) : 405 - 418