Two-detector Corrected Near Infrared Spectroscopy (C-NIRS) detects hemodynamic activation responses more robustly than single-detector NIRS

被引:140
作者
Saager, Rolf B. [1 ]
Telleri, Nicole L. [2 ]
Berger, Andrew J. [1 ]
机构
[1] Univ Rochester, Inst Opt, Rochester, NY 14627 USA
[2] Univ Rochester, Dept Biomed Engn, Rochester, NY 14627 USA
基金
美国国家科学基金会;
关键词
Near-infrared spectroscopy; Cerebral hemodynamics; Functional imaging; Layer model; CEREBRAL HEMODYNAMICS; BRAIN ACTIVATION; ADULT HEAD; MEDIA; MODEL;
D O I
10.1016/j.neuroimage.2011.01.043
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In near-infrared spectroscopy (NIRS) of human cerebral hemodynamics, detection of stimulus-related responses is confounded by the presence of unrelated trends in both the brain and the overlying scalp. A proposed strategy for reducing hemodynamic noise has been to record "scalp only" trends simultaneously via a second shorter-separation detector (similar to 5 mm rather than similar to 30 mm) and perform a subtraction (C-NIRS, for "corrected near-infrared spectroscopy"). To compare the single- and dual-detector strategies, a 21-volunteer study of visual stimulation responses (6 stimulation blocks and 8 recording channels per measurement run) has been conducted. Activation-flagged channels were defined based upon (a) the significance (p-value) of the average rise in oxyhemoglobin concentration and (b) the average signal-to-noise over 6 stimulation epochs. At reasonable thresholds (p < 0.025, SNR > 1), the C-NIRS method increased the number of activation-flagged channels from 47 to 66, an increase of 40%, adding 24 channels and eliminating only 5. Of the 71 channels that were activation-flagged by at least one modality, the C-NIRS time series exhibited more significant oxyhemoglobin rise in 80% of such channels, and better signal-to-noise in 73%. In addition, single-subject C-NIRS stimulus responses were more consistent than NIRS over the six stimulation epochs, with significantly lower coefficients of variation in both amplitude and latency (i.e. time between stimulus onset and maximum hemoglobin rise). These results demonstrate that two-detector C-NIRS provides a straightforward way of (a) removing hemodynamic interference from NIRS data, (b) increasing the detection rate of cerebrally-unique responses, and (c) improving the quality of those recorded responses. Parallel insights regarding deoxyhemoglobin trends could not be drawn from this data set but should be attainable in future studies with higher signal to noise ratios. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:1679 / 1685
页数:7
相关论文
共 28 条
[1]   Real-time imaging of human brain function by near-infrared spectroscopy using an adaptive general linear model [J].
Abdelnour, A. Farras ;
Huppert, Theodore .
NEUROIMAGE, 2009, 46 (01) :133-143
[2]   The accuracy of near infrared spectroscopy and imaging during focal changes in cerebral hemodynamics [J].
Boas, DA ;
Gaudette, T ;
Strangman, G ;
Cheng, XF ;
Marota, JJA ;
Mandeville, JB .
NEUROIMAGE, 2001, 13 (01) :76-90
[3]   Dynamics of blood flow and oxygenation changes during brain activation: The balloon model [J].
Buxton, RB ;
Wong, EC ;
Frank, LR .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) :855-864
[4]   A novel method for fast imaging of brain function, non-invasively, with light [J].
Chance, B ;
Anday, E ;
Nioka, S ;
Zhou, S ;
Hong, L ;
Worden, K ;
Li, C ;
Murray, T ;
Ovetsky, Y ;
Pidikiti, D ;
Thomas, R .
OPTICS EXPRESS, 1998, 2 (10) :411-423
[5]   Volumetric diffuse optical tomography of brain activity [J].
Culver, JP ;
Siegel, AM ;
Stott, JJ ;
Boas, DA .
OPTICS LETTERS, 2003, 28 (21) :2061-2063
[6]   OPTICAL PATHLENGTH MEASUREMENTS ON ADULT HEAD, CALF AND FOREARM AND THE HEAD OF THE NEWBORN-INFANT USING PHASE-RESOLVED OPTICAL SPECTROSCOPY [J].
DUNCAN, A ;
MEEK, JH ;
CLEMENCE, M ;
ELWELL, CE ;
TYSZCZUK, L ;
COPE, M ;
DELPY, DT .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (02) :295-304
[7]   Optical measurements of absorption changes in two-layered diffusive media [J].
Fabbri, F ;
Sassaroli, A ;
Henry, ME ;
Fantini, S .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (07) :1183-1201
[8]   Non-invasive optical monitoring of the newborn piglet brain using continuous-wave and frequency-domain spectroscopy [J].
Fantini, S ;
Hueber, D ;
Franceschini, MA ;
Gratton, E ;
Rosenfeld, W ;
Stubblefield, PG ;
Maulik, D ;
Stankovic, MR .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (06) :1543-1563
[9]   On-line optical imaging of the human brain with 160-ms temporal resolution [J].
Franceschini, MA ;
Toronov, V ;
Filiaci, ME ;
Gratton, E ;
Fantini, S .
OPTICS EXPRESS, 2000, 6 (03) :49-57
[10]   New multichannel near infrared spectrophotometry system for functional studies of the brain in adults and neonates [J].
Haensse, D ;
Szabo, P ;
Brown, D ;
Fauchère, JC ;
Niederer, P ;
Bucher, HU ;
Wolf, M .
OPTICS EXPRESS, 2005, 13 (12) :4525-4538