Extreme hemodilution with PEG-hemoglobin vs. PEG-albumin

被引:35
作者
Cabrales, P
Tsai, AG
Winslow, RM
Intaglietta, M
机构
[1] La Jolla Bioengn Inst, La Jolla, CA 92037 USA
[2] Sangart Inc, San Diego, CA USA
[3] Univ Calif San Diego, Dept Bioengn, La Jolla, CA 92093 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2005年 / 289卷 / 06期
关键词
microcirculation; functional capillary density; cardiac output; oxygen release; blood substitutes; plasma expanders; polyethylene glycol-albumin; polyethylene glycol-hemoglobin;
D O I
10.1152/ajpheart.00225.2005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Isovolemic hemodilution to 11% systemic hematocrit was performed in the hamster window chamber model using 6% dextran 70 kDa (Dx 70) and 5% human serum albumin (HSA). Systemic and microvascular effects of these solutions were compared with polyethylene glycol (PEG)-conjugated 5% albumin (MPA) and PEG-conjugated 4.2% Hb (MP4). These studies were performed for the purpose of comparing systemic and microvascular responses of PEG vs. non-PEG plasma expanders and similar oxygen-carrying vs. noncarrying blood replacement fluids. Mean arterial blood pressure was statistically significantly reduced for all groups compared with baseline (P < 0.05), HSA, MPA, and MP4 higher than Dx 70 (P < 0.05). MP4 and MPA had a significantly higher cardiac index than HSA and Dx 70, in addition to a positive base excess. Microvascular blood flow and capillary perfusion were significantly higher for the PEG compounds compared with HSA and Dx 70. Intravascular PO2 for MP4 and MPA was higher in arterioles (P < 0.05) compared with HSA and Dx 70, but there was no difference in either tissue or venular PO2 between groups. Total Hb in the MP4 group was 4.8 +/- 0.4 g/dl, whereas the remaining groups had a range of 3.6-3.8 g/dl. The hemodilution results showed that PEG compounds maintained microvascular conditions with lower concentrations than conventional plasma expanders. Furthermore, microvascular oxygen delivery and extraction in the window chamber tissue were significantly higher for the PEG compounds. MP4 was significantly higher than MPA (P < 0.05) and was not statistically different from baseline, an effect due to the additional oxygen release to the tissue by the Hb MP4.
引用
收藏
页码:H2392 / H2400
页数:9
相关论文
共 37 条
[1]   Statistics notes - How to randomise [J].
Altman, DG ;
Bland, JM .
BRITISH MEDICAL JOURNAL, 1999, 319 (7211) :703-704
[2]   ON-LINE VOLUME FLOW-RATE AND VELOCITY PROFILE MEASUREMENT FOR BLOOD IN MICROVESSELS [J].
BAKER, M ;
WAYLAND, H .
MICROVASCULAR RESEARCH, 1974, 7 (01) :131-143
[3]  
Björkholm M, 2005, HAEMATOLOGICA, V90, P505
[4]   In vivo pO2 measurements in hamster skinfold by recessed pO2 microelectrodes and phosphorescence quenching are in agreement [J].
Buerk, DG ;
Tsai, AG ;
Intaglietta, M ;
Johnson, PC .
MICROCIRCULATION, 1998, 5 (2-3) :219-225
[5]   Oxygen delivery and consumption in the microcirculation after extreme hemodilution with perfluorocarbons [J].
Cabrales, P ;
Tsai, AG ;
Frangos, JA ;
Briceño, JC ;
Intaglietta, M .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2004, 287 (01) :H320-H330
[6]   Oxygen transport by low and normal oxygen affinity hemoglobin vesicles in extreme hemodilution [J].
Cabrales, P ;
Sakai, H ;
Tsai, AG ;
Takeoka, S ;
Tsuchida, E ;
Intaglietta, M .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2005, 288 (04) :H1885-H1892
[7]   Alginate plasma expander maintains perfusion and plasma viscosity during extreme hemodilution [J].
Cabrales, P ;
Tsai, AG ;
Intaglietta, M .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2005, 288 (04) :H1708-H1716
[8]   Effects of extreme hemodilution with hemoglobin- based O2 carriers on microvascular pressure [J].
Cabrales, P ;
Tsai, AG ;
Winslow, RM ;
Intaglietta, M .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2005, 288 (05) :H2146-H2153
[9]   Increased tissue PO2 and decreased O2 delivery and consumption after 80% exchange transfusion with polymerized hemoglobin [J].
Cabrales, P ;
Tsai, AG ;
Intaglietta, M .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2004, 287 (06) :H2825-H2833
[10]   Microvascular PO2 during extreme hemodilution with hemoglobin site specifically PEGylated at Cys-93(β) in hamster window chamber [J].
Cabrales, P ;
Kanika, ND ;
Manjula, BN ;
Tsai, AG ;
Acharya, SA ;
Intaglietta, M .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2004, 287 (04) :H1609-H1617