Cranial CT with Adaptive Statistical Iterative Reconstruction: Improved Image Quality with Concomitant Radiation Dose Reduction

被引:88
作者
Rapalino, O. [1 ]
Kamalian, Shervin [1 ]
Kamalian, Shahmir [1 ]
Payabvash, S. [1 ]
Souza, L. C. S. [1 ]
Zhang, D. [1 ]
Mukta, J. [2 ]
Sahani, D. V. [1 ]
Lev, M. H. [1 ]
Pomerantz, S. R. [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] CT Res, GE Healthcare, Boston, MA USA
关键词
COMPUTED-TOMOGRAPHY;
D O I
10.3174/ajnr.A2826
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
BACKGROUND AND PURPOSE: To safeguard patient health, there is great interest in CT radiation-dose reduction. The purpose of this study was to evaluate the impact of an iterative-reconstruction algorithm, ASIR, on image-quality measures in reduced-dose head CT scans for adult patients. MATERIALS AND METHODS: Using a 64-section scanner, we analyzed 100 reduced-dose adult head CT scans at 6 predefined levels of ASIR blended with FBP reconstruction. These scans were compared with 50 CT scans previously obtained at a higher routine dose without ASIR reconstruction. SNR and CNR were computed from Hounsfield unit measurements of normal GM and WM of brain parenchyma. A blinded qualitative analysis was performed in 10 lower-dose CT datasets compared with higher-dose ones without ASIA. Phantom data analysis was also performed. RESULTS: Lower-dose scans without ASIA had significantly lower mean GM and WM SNR (P = .003) and similar GM-WM CNR values compared with higher routine-dose scans. However, at ASIR levels of 20%-40%, there was no statistically significant difference in SNR, and at ASIR levels of >= 60%, the SNR values of the reduced-dose scans were significantly higher (P < .011. CNR values were also significantly higher at ASIA levels of >= 40% (P < .011. Blinded qualitative review demonstrated significant improvements in perceived image noise, artifacts, and GM-WM differentiation at ASIA levels >= 60 AD (P < .01). CONCLUSIONS: These results demonstrate that the use of ASIA in adult head CT scans reduces image noise and increases low-contrast resolution, while allowing lower radiation doses without affecting spatial resolution.
引用
收藏
页码:609 / 615
页数:7
相关论文
共 20 条
[1]
ACR, 2008, ACR PRACT GUID DIAGN
[2]
ACR, 2011, CT ACCR PHANT INSTR
[3]
The radiologist's conundrum: benefits and costs of increasing CT capacity and utilization - Opinion [J].
Boland, Giles W. L. ;
Guimaraes, Alexander S. ;
Mueller, Peter R. .
EUROPEAN RADIOLOGY, 2009, 19 (01) :9-11
[4]
Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[5]
ALGEBRAIC RECONSTRUCTION TECHNIQUES (ART) FOR 3-DIMENSIONAL ELECTRON MICROSCOPY AND X-RAY PHOTOGRAPHY [J].
GORDON, R ;
BENDER, R ;
HERMAN, GT .
JOURNAL OF THEORETICAL BIOLOGY, 1970, 29 (03) :471-&
[6]
Low-Tube-Voltage, High-Tube-Current Multidetector Abdominal CT: Improved Image Quality and Decreased Radiation Dose with Adaptive Statistical Iterative Reconstruction Algorithm-Initial Clinical Experience [J].
Marin, Daniele ;
Nelson, Rendon C. ;
Schindera, Sebastian T. ;
Richard, Samuel ;
Youngblood, Richard S. ;
Yoshizumi, Terry T. ;
Samei, Ehsan .
RADIOLOGY, 2010, 254 (01) :145-153
[7]
McCollough C, 2008, AAPM Report No. 96
[8]
The phantom portion of the American College of Radiology (ACR) Computed Tomography (CT) accreditation program: Practical tips, artifact examples, and pitfalls to avoid [J].
McCollough, CH ;
Bruesewitz, MR ;
McNitt-Gray, MF ;
Bush, K ;
Ruckdeschel, T ;
Payne, JT ;
Brink, JA ;
Zeman, RK .
MEDICAL PHYSICS, 2004, 31 (09) :2423-2442
[9]
Strategies for Reducing Radiation Dose in CT [J].
McCollough, Cynthia H. ;
Primak, Andrew N. ;
Braun, Natalie ;
Kofler, James ;
Yu, Lifeng ;
Christner, Jodie .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2009, 47 (01) :27-+
[10]
Mullins ME, 2004, AM J NEURORADIOL, V25, P533