Computer-aided detection in CT colonography:: initial clinical experience using a prototype system

被引:14
作者
Graser, A.
Kolligs, F. T.
Mang, T.
Schaefer, C.
Geisbuesch, S.
Reiser, M. F.
Becker, C. R.
机构
[1] Univ Munich, Dept Clin Radiol, D-81377 Munich, Germany
[2] Univ Munich, Dept Gastroenterol Med Klin & Poliklin 2, D-81377 Munich, Germany
[3] Med Univ Vienna, Dept Radiol, A-1090 Vienna, Austria
关键词
computed tomography; CT colonography; computer-aided detection;
D O I
10.1007/s00330-007-0579-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Computer-aided detection (CAD) algorithms help to detect colonic polyps at CT colonography (CTC). The purpose of this study was to evaluate the accuracy of CAD versus an expert reader in CTC. One hundred forty individuals (67 men, 73 women; mean age, 59 years) underwent screening 64-MDCT colonography after full cathartic bowel cleansing without fecal tagging. One expert reader interpreted supine and prone scans using a 3D workstation with integrated CAD used as "second reader." The system's sensitivity for the detection of polyps, the number of false-positive findings, and its running time were evaluated. Polyps were classified as small (<= 5 mm), medium (6-9 mm), and large (>= 10 mm). A total of 118 polyps (small, 85; medium, 19; large, 14) were found in 56 patients. CAD detected 72 polyps (61%) with an average of 2.2 false-positives. Sensitivity was 51% (43/85) for small, 90% (17/19) for medium, and 86% (12/14) for large polyps. For all polyps, per-patient sensitivity was 89% (50/56) for the radiologist and 73% (41/56) for CAD. For large and medium polyps, per-patient sensitivity was 100% for the radiologist, and 96% for CAD. In conclusion, CAD shows high sensitivity in the detection of clinically significant polyps with acceptable false-positive rates.
引用
收藏
页码:2608 / 2615
页数:8
相关论文
共 21 条
[1]   Computer-aided detection (CAD) for CT colonography: a tool to address a growing need [J].
Bogoni, L ;
Cathier, P ;
Dundar, M ;
Jerebko, A ;
Lakare, S ;
Liang, J ;
Periaswamy, S ;
Baker, ME ;
MacAri, M .
BRITISH JOURNAL OF RADIOLOGY, 2005, 78 :S57-S62
[2]   CT colonography interpretation times: effect of reader experience, fatigue, and scan findings in a multi-centre setting [J].
Burling, David ;
Halligan, Steve ;
Altman, Douglas G. ;
Atkin, Wendy ;
Bartram, Clive ;
Fenlon, Helen ;
Laghi, Andrea ;
Stoker, Jaap ;
Taylor, Stuart ;
Frost, Roger ;
Dessey, Guido ;
De Villiers, Melinda ;
Florie, Jasper ;
Foley, Shane ;
Honeyfield, Lesley ;
Iannaccone, Riccardo ;
Gallo, Teresa ;
Kay, Clive ;
Lefere, Philippe ;
Lowe, Andrew ;
Mangiapane, Filipo ;
Marrannes, Jesse ;
Neri, Emmanuele ;
Nieddu, Giulia ;
Nicholson, David ;
O'Hare, Alan ;
Ori, Sante ;
Politi, Benedetta ;
Poulus, Martin ;
Regge, Daniele ;
Renaut, Lisa ;
Rudralingham, Velauthan ;
Signoretta, Saverio ;
Vagli, Paola ;
Van der Hulst, Victor ;
Williams-Butt, Jane .
EUROPEAN RADIOLOGY, 2006, 16 (08) :1745-1749
[3]   Computed tomographic colonography (virtual colonoscopy) - A multicenter comparison with standard colonoscopy for detection of colorectal neoplasia [J].
Cotton, PB ;
Durkalski, VL ;
Benoit, PC ;
Palesch, YY ;
Mauldin, PD ;
Hoffman, B ;
Vining, DJ ;
Small, WC ;
Affronti, J ;
Rex, D ;
Kopecky, KK ;
Ackerman, S ;
Burdick, JS ;
Brewington, C ;
Turner, MA ;
Zfass, A ;
Wright, AR ;
Iyer, RB ;
Lynch, P ;
Sivak, MV ;
Butler, H .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 291 (14) :1713-1719
[4]   A statistical 3-D pattern processing method for computer-aided detection of polyps in CT colonography [J].
Göktürk, SB ;
Tomasi, C ;
Acar, B ;
Beaulieu, CF ;
Paik, DS ;
Jeffrey, RB ;
Yee, J ;
Napel, S .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (12) :1251-1260
[5]   Dose reduction and image quality in MDCT colonography using tube current modulation [J].
Graser, A. ;
Wintersperger, B. J. ;
Suess, C. ;
Reiser, M. F. ;
Becker, C. R. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (03) :695-701
[6]   CT colonography in the detection of colorectal polyps and cancer: Systematic review meta-analysis and proposed minimum data set for study level reporting [J].
Halligan, S ;
Altman, DG ;
Taylor, SA ;
Mallett, S ;
Deeks, JJ ;
Bartram, CI ;
Atkin, W .
RADIOLOGY, 2005, 237 (03) :893-904
[7]   Multiple neural network classification scheme for detection of colonic polyps in CT colonography data sets [J].
Jerebko, AK ;
Malley, JD ;
Franaszek, M ;
Summers, RM .
ACADEMIC RADIOLOGY, 2003, 10 (02) :154-160
[8]   The diagnostic value of multiplanar reconstruction on MDCT colonography for the preoperative staging of colorectal cancer [J].
Jin, Kwang Nam ;
Lee, Jeong Min ;
Kim, Se Hyung ;
Shin, Kyung-Sook ;
Lee, Jae Young ;
Han, Joon Koo ;
Choi, Byung Ihn .
EUROPEAN RADIOLOGY, 2006, 16 (10) :2284-2291
[9]   Computer-aided diagnosis in virtual colonography via combination of surface normal and sphere fitting methods [J].
Kiss, G ;
Van Cleynenbreugel, J ;
Thomeer, M ;
Suetens, P ;
Marchal, G .
EUROPEAN RADIOLOGY, 2002, 12 (01) :77-81
[10]   Venous malformations mimicking multiple mucosal polyps on screening CT colonography [J].
Lee, AD ;
Pickhardt, PJ ;
Gopal, DV ;
Taylor, AJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (04) :1113-1115