摘要
Speciation of elements in natural matrices, especially of trace metals, is one of the predominant development trends of modern inorganic analysis. The main part of the conventional speciation procedures is a suitable combination of separation and chemical conversion steps, for which the most appropriate methodology seems to be the use of flow-injection. A shorter time of performance of these operations in flow-injection manifolds is advantageous in terms of avoiding the shift of chemical equilibria during the speciation measurement. Numerous other advantages are also pointed out in this review based on 58 references. Among flow-injection analysis methods published so far for speciation the determination of different oxidation states predominates, while a much smaller number of papers have been published on the determination of the degree of complexation or the determination of organometallic compounds.
引用
收藏
页码:825 / 838
页数:14
相关论文
共 58 条
[21]   THE ROLE OF FLOW-INJECTION ANALYSIS IN SPECIATION STUDIES [J].
DECASTRO, MDL .
MIKROCHIMICA ACTA, 1992, 109 (1-4) :165-168
[22]   SPECIATION OF MERCURY IN NATURAL-WATERS BY CAPILLARY GAS-CHROMATOGRAPHY WITH A MICROWAVE-INDUCED PLASMA EMISSION DETECTOR FOLLOWING PRECONCENTRATION USING A DITHIOCARBAMATE RESIN MICROCOLUMN INSTALLED IN A CLOSED FLOW-INJECTION SYSTEM [J].
EMTEBORG, H ;
BAXTER, DC ;
FRECH, W .
ANALYST, 1993, 118 (08) :1007-1013
[23]   APPLICATION OF A REDUCING COLUMN FOR METAL SPECIATION BY FLOW-INJECTION ANALYSIS - SPECTROPHOTOMETRIC DETERMINATION OF IRON(III) AND SIMULTANEOUS DETERMINATION OF IRON(II) AND TOTAL IRON [J].
FAIZULLAH, AT ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1985, 167 (JAN) :225-231
[24]   FLOW-INJECTION ANALYSIS - LEAVING ITS TEEN-YEARS AND MATURING - A PERSONAL REMINISCENCE OF ITS CONCEPTION AND EARLY DEVELOPMENT [J].
HANSEN, EH .
ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) :3-13
[25]  
Jian Wei, 1992, Talanta, V39, P1537
[26]  
KRAMER JR, 1988, METAL SPECIATION
[27]   SIMULTANEOUS DETERMINATION OF IRON(II)/IRON(III) BY SORBENT EXTRACTION WITH FLOW-INJECTION ATOMIC-ABSORPTION DETECTION [J].
KREKLER, S ;
FRENZEL, W ;
SCHULZE, G .
ANALYTICA CHIMICA ACTA, 1994, 296 (02) :115-117
[28]  
Leppard GG, 1983, TRACE ELEMENT SPECIA
[29]   FLOW-INJECTION ANALYSIS OF BINARY AND TERNARY MIXTURES OF ARSENITE, ARSENATE, AND PHOSPHATE [J].
LINARES, P ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1986, 58 (01) :120-124
[30]   STUDIES ON THE APPLICATION OF PHOTOCHEMICAL-REACTIONS IN A FLOW-INJECTION SYSTEM .2. SIMULTANEOUS DETERMINATION OF IRON(II) AND IRON(III) BASED ON THE PHOTOREDUCTION OF THE IRON(III)-PHENANTHROLINE COMPLEX [J].
LIU, RM ;
LIU, DJ ;
SUN, AL .
ANALYST, 1992, 117 (11) :1767-1770