Prussian Blue bulk modified screen-printed electrodes for H2O2 detection and for biosensors

被引:192
作者
O'Halloran, MP [1 ]
Pravda, M [1 ]
Guilbault, GG [1 ]
机构
[1] Natl Univ Ireland Univ Coll Cork, Dept Chem, Sensors Dev Grp, Cork, Ireland
关键词
Prussian blue; screen-printed electrode; hydrogen peroxide; biosensors; glucose oxidase; mediator;
D O I
10.1016/S0039-9140(01)00469-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensor for H2O2 amperometric detection based on a Prussian Blue (PB) bulk modified carbon screen-printed electrode was developed. It has been optimised with respect to the lowest limit of detection achieved. PB was made chemically by the reaction of FeCl3 with K-4[Fe(CN)(6)]. The resulting powder, obtained by forced crystallisation induced by acetone, was dried and activated at 150 degreesC for 10 h. PB microparticles (< 38 mum) were prepared and mixed with carbon ink. The limit of detection achieved was 0.4 muM with the linear range up to 100 muM of H2O2 with the sensitivity of 137 muA mM(-1) cm(-1), that was comparable with sensors based on electrodeposited PB film. The transducer was applied for a glucose biosensor, that exhibited LOD of 0.22 mM, linear range up to 3 mM, K, K-M(app) of 4.6 mM, and the sensitivity of 3.21 +/- 0.16 muA mM(-1) cm(-1). The peroxide sensor, as well as the glucose biosensor, were totally insensitive to oxygen, ascorbate, urate, and paracetamol. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:605 / 611
页数:7
相关论文
共 32 条
[1]   Sol-gel-derived prussian blue-silicate amperometric glucose biosensor [J].
Bharathi, S ;
Lev, O .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2000, 89 (2-3) :209-216
[2]   AMPEROMETRIC BIOSENSORS BASED ON THE IMMOBILIZATION OF OXIDASES IN A PRUSSIAN BLUE FILM BY ELECTROCHEMICAL CODEPOSITION [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1995, 310 (03) :429-436
[3]   Development of biosensors based on hexacyanoferrates [J].
de Mattos, IL ;
Gorton, L ;
Laurell, T ;
Malinauskas, A ;
Karyakin, AA .
TALANTA, 2000, 52 (05) :791-799
[4]   ELECTROCHROMISM IN THE MIXED-VALENCE HEXACYANIDES .1. VOLTAMMETRIC AND SPECTRAL STUDIES OF THE OXIDATION AND REDUCTION OF THIN-FILMS OF PRUSSIAN BLUE [J].
ELLIS, D ;
ECKHOFF, M ;
NEFF, VD .
JOURNAL OF PHYSICAL CHEMISTRY, 1981, 85 (09) :1225-1231
[5]   Study of Prussian Blue (PB) films by ac-electrogravimetry:: influence of PB morphology on ions movement [J].
García-Jareño, JJ ;
Sanmatías, A ;
Vicente, F ;
Gabrielli, C ;
Keddam, M ;
Perrot, H .
ELECTROCHIMICA ACTA, 2000, 45 (22-23) :3765-3776
[6]   Electrochemical study of Nafion membranes/Prussian blue films on ITO electrodes [J].
GarciaJareno, JJ ;
NavarroLaboulais, J ;
Vicente, F .
ELECTROCHIMICA ACTA, 1996, 41 (17) :2675-2682
[7]   Amperometric glucose biosensors based on Prussian Blue- and polyaniline-glucose oxidase modified electrodes [J].
Garjonyte, R ;
Malinauskas, A .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (9-10) :445-451
[8]   Glucose biosensor based on glucose oxidase immobilized in electropolymerized polypyrrole and poly(o-phenylenediamine) films on a Prussian Blue-modified electrode [J].
Garjonyte, R ;
Malinauskas, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 63 (1-2) :122-128
[9]   Electrocatalytic reactions of hydrogen peroxide at carbon paste electrodes modified by some metal hexacyanoferrates [J].
Garjonyte, R ;
Malinauskas, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 46 (03) :236-241
[10]   Operational stability of amperometric hydrogen peroxide sensors, based on ferrous and copper hexacyanoferrates [J].
Garjonyte, R ;
Malinauskas, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 56 (1-2) :93-97