Prussian Blue bulk modified screen-printed electrodes for H2O2 detection and for biosensors

被引:192
作者
O'Halloran, MP [1 ]
Pravda, M [1 ]
Guilbault, GG [1 ]
机构
[1] Natl Univ Ireland Univ Coll Cork, Dept Chem, Sensors Dev Grp, Cork, Ireland
关键词
Prussian blue; screen-printed electrode; hydrogen peroxide; biosensors; glucose oxidase; mediator;
D O I
10.1016/S0039-9140(01)00469-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensor for H2O2 amperometric detection based on a Prussian Blue (PB) bulk modified carbon screen-printed electrode was developed. It has been optimised with respect to the lowest limit of detection achieved. PB was made chemically by the reaction of FeCl3 with K-4[Fe(CN)(6)]. The resulting powder, obtained by forced crystallisation induced by acetone, was dried and activated at 150 degreesC for 10 h. PB microparticles (< 38 mum) were prepared and mixed with carbon ink. The limit of detection achieved was 0.4 muM with the linear range up to 100 muM of H2O2 with the sensitivity of 137 muA mM(-1) cm(-1), that was comparable with sensors based on electrodeposited PB film. The transducer was applied for a glucose biosensor, that exhibited LOD of 0.22 mM, linear range up to 3 mM, K, K-M(app) of 4.6 mM, and the sensitivity of 3.21 +/- 0.16 muA mM(-1) cm(-1). The peroxide sensor, as well as the glucose biosensor, were totally insensitive to oxygen, ascorbate, urate, and paracetamol. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:605 / 611
页数:7
相关论文
共 32 条
[11]   CARBON-PASTE ELECTRODES MODIFIED WITH ENZYMES, TISSUES, AND CELLS [J].
GORTON, L .
ELECTROANALYSIS, 1995, 7 (01) :23-45
[12]   CATALYSIS OF THE REDUCTION OF MOLECULAR-OXYGEN TO WATER AT PRUSSIAN BLUE MODIFIED ELECTRODES [J].
ITAYA, K ;
SHOJI, N ;
UCHIDA, I .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1984, 106 (12) :3423-3429
[13]   ELECTROCHEMISTRY OF PRUSSIAN BLUE MODIFIED ELECTRODES - AN ELECTROCHEMICAL PREPARATION METHOD [J].
ITAYA, K ;
AKAHOSHI, H ;
TOSHIMA, S .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1982, 129 (07) :1498-1500
[14]   Novel hexacyanoferrate(III) modified graphite disc electrodes and their application in enzyme electrodes .1. [J].
Jaffari, SA ;
Turner, APF .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (01) :1-9
[15]   The electrocatalytic activity of Prussian blue in hydrogen peroxide reduction studied using a wall-jet electrode with continuous flow [J].
Karyakin, AA ;
Karyakina, EE ;
Gorton, L .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 456 (1-2) :97-104
[16]   On the mechanism of H2O2 reduction at Prussian Blue modified electrodes [J].
Karyakin, AA ;
Karyakina, EE ;
Gorton, L .
ELECTROCHEMISTRY COMMUNICATIONS, 1999, 1 (02) :78-82
[17]   Improvement of electrochemical biosensors using enzyme immobilization from water-organic mixtures with a high content of organic solvent [J].
Karyakin, AA ;
Karyakina, EE ;
Gorton, L ;
Bobrova, OA ;
Lukachova, LV ;
Gladilin, AK ;
Levashov, AV .
ANALYTICAL CHEMISTRY, 1996, 68 (24) :4335-4341
[18]   A HIGH-SENSITIVE GLUCOSE AMPEROMETRIC BIOSENSOR BASED ON PRUSSIAN-BLUE MODIFIED ELECTRODES [J].
KARYAKIN, AA ;
GITELMACHER, OV ;
KARYAKINA, EE .
ANALYTICAL LETTERS, 1994, 27 (15) :2861-2869
[19]   PRUSSIAN BLUE BASED FIRST-GENERATION BIOSENSOR - A SENSITIVE AMPEROMETRIC ELECTRODE FOR GLUCOSE [J].
KARYAKIN, AA ;
GITELMACHER, OV ;
KARYAKINA, EE .
ANALYTICAL CHEMISTRY, 1995, 67 (14) :2419-2423
[20]   Prussian Blue-based 'artificial peroxidase' as a transducer for hydrogen peroxide detection. Application to biosensors [J].
Karyakin, AA ;
Karyakina, EE .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 57 (1-3) :268-273