Exploring the discrimination power of the time domain for segmentation and characterization of active lesions in serial MR data

被引:45
作者
Gerig, G [1 ]
Welti, D
Guttmann, CRG
Colchester, ACF
Székely, G
机构
[1] Univ N Carolina, Dept Comp Sci, Chapel Hill, NC 27514 USA
[2] Swiss Fed Inst Technol ETH, Zurich, Switzerland
[3] Harvard Univ, Brigham & Womens Hosp, Sch Med, Boston, MA 02115 USA
[4] Univ Kent, Canterbury, Kent, England
关键词
time series analysis; lesions in magnetic resonance imaging; temporal analysis; multiple sclerosis;
D O I
10.1016/S1361-8415(00)00005-0
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper presents a new method for the automatic segmentation and characterization of object changes in time series of three-dimensional data sets. The technique was inspired by procedures developed for analysis of functional MRI data sets. After precise registration of serial volume data sets to 4-D data, we applied a time series analysis taking into account the characteristic time function of variable lesions. The images were preprocessed with a correction of image field inhomogeneities and a normalization of the brightness over the whole time series, Thus, static regions remain unchanged over time, whereas changes in tissue characteristics produce typical intensity variations in the voxel's time series. A set of features was derived from the times series, expressing probabilities for membership to the sought structures. These multiple sources of uncertain evidence were combined to a single evidence value using Dempster-Shafer's theory. The project was driven by the objective of improving the segmentation and characterization of white matter lesions in serial MR data of multiple sclerosis patients. Pharmaceutical research and patient follow-up requires efficient and robust methods with a high degree of automation. The new approach replaces conventional segmentation of series of 3-D data sets by a 1-D processing of the temporal change at each voxel in the 4-D image data set. The new method has been applied to a total of 11 time series from different patient studies, covering time resolutions of 12 and 24 data sets over a period of about 1 year. The results demonstrate that time evolution is a highly sensitive feature for detection of fluctuating structures. (C) 2000 Elsevier Science BN, All rights reserved.
引用
收藏
页码:31 / 42
页数:12
相关论文
共 22 条
[1]  
ANDERSON K, 1996, HUMAN EXPT TOXICOLOG, V15, P154
[2]   PROCESSING STRATEGIES FOR TIME-COURSE DATA SETS IN FUNCTIONAL MRI OF THE HUMAN BRAIN [J].
BANDETTINI, PA ;
JESMANOWICZ, A ;
WONG, EC ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) :161-173
[3]  
*BIOMORPH EUBIOMED, 1999, BMH4CT960845 BIOMORP
[4]  
Brechbuhler C, 1996, LECT NOTES COMPUT SC, V1131, P141, DOI 10.1007/BFb0046948
[5]   The role of MRI in clinical trials of multiple sclerosis: Comparison of image processing techniques [J].
Evans, AC ;
Frank, JA ;
Antel, J ;
Miller, DH .
ANNALS OF NEUROLOGY, 1997, 41 (01) :125-132
[6]   UNSUPERVISED TISSUE-TYPE SEGMENTATION OF 3D DUAL-ECHO MR HEAD DATA [J].
GERIG, G ;
MARTIN, J ;
KIKINIS, R ;
KUBLER, O ;
SHENTON, M ;
JOLESZ, FA .
IMAGE AND VISION COMPUTING, 1992, 10 (06) :349-360
[7]  
GORDON J, 1985, RULE BASED EXPERT SY, P272
[8]  
GUTTMANN CRG, 1995, AM J NEURORADIOL, V16, P1481
[9]  
HILL DLG, 1995, P SMR 3 ANN M NIC, P840
[10]   MODEL-BASED 3-D SEGMENTATION OF MULTIPLE-SCLEROSIS LESIONS IN MAGNETIC-RESONANCE BRAIN IMAGES [J].
KAMBER, M ;
SHINGHAL, R ;
COLLINS, DL ;
FRANCIS, GS ;
EVANS, AC .