An initial qualitative study of dual-energy CT in the knee ligaments

被引:118
作者
Sun, Cong [1 ]
Miao, Fan [2 ]
Wang, Xi-ming [1 ]
Wang, Tao [1 ]
Ma, Rui [1 ]
Wang, Dao-ping [1 ]
Liu, Cheng [1 ]
机构
[1] Shandong Prov Med Imaging Inst, Jinan 250021, Shandong, Peoples R China
[2] Shandong Prov Hosp, Jinan, Shandong, Peoples R China
关键词
dual-energy CT; knee; ligament; X-ray computed tomography;
D O I
10.1007/s00276-008-0349-y
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 [人体解剖与组织胚胎学];
摘要
Objective To study the clinical application of dual-energy CT (DECT) in the knee ligaments. Methods Twelve cases (24 knees) were scanned using dual-energy CT for the knee. Two- and three-dimensional images were used for display in all cases by means of multi-planar reformation (MPR) and volume rendering technique (VRT). All images were ranked by two radiologists according to the grade of knee ligament displayed, the definition of edge and attachment points of the knee ligament. Results The partial ligaments of 24 knees, such as the patellar ligament, fibular collateral ligament, anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL) were clearly displayed; the tibial collateral ligament was not satisfactorily displayed. The transversal ligaments, such as lateral patellar retinaculum and medial patellar retinaculum, and the posterior ligament, such as oblique popliteal ligament could not be shown clearly. Conclusion The dual-energy CT is a new and valuable tool to qualitatively display the main ligaments of the knee.
引用
收藏
页码:443 / 447
页数:5
相关论文
共 9 条
[1]
Contrast-enhanced coronary artery visualization by dual-source computed tomography - Initial experience [J].
Achenbach, S ;
Ropers, D ;
Kuettner, A ;
Flohr, T ;
Ohnesorge, B ;
Bruder, H ;
Theessen, H ;
Karakaya, M ;
Daniel, WG ;
Bautz, W ;
Kalender, WA ;
Anders, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :331-335
[2]
CT arthrography [J].
Buckwalter, Kenneth A. .
CLINICS IN SPORTS MEDICINE, 2006, 25 (04) :899-+
[3]
In vivo glenohumeral analysis using 3D MRI models and a flexible software tool: Feasibility and precision [J].
Busse, Harald ;
Thomas, Michael ;
Seiwerts, Matthias ;
Moche, Michael ;
Busse, Martin W. ;
von Salis-Soglio, Georg ;
Kahn, Thomas .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (01) :162-170
[4]
Anterior cruciate ligament volume: Analysis of gender differences [J].
Fayad, Laura M. ;
Rosenthal, Elan H. ;
Morrison, William B. ;
Carrino, John A. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (01) :218-223
[5]
First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[6]
Isotropic MRI of the knee with 3D fast spin-echo extended echo-train acquisition (XETA): Initial experience [J].
Gold, Garry E. ;
Busse, Reed F. ;
Beehler, Carol ;
Han, Eric ;
Brau, Anja C. S. ;
Beatty, Philip J. ;
Beaulieu, Christopher F. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05) :1287-1293
[7]
Material differentiation by dual energy CT: initial experience [J].
Johnson, Thorsten R. C. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Grasruck, Michael ;
Bruder, Herbert ;
Morhard, Dominik ;
Fink, Christian ;
Weckbach, Sabine ;
Lenhard, Miriam ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1510-1517
[8]
Vande Berg B C, 2002, Semin Musculoskelet Radiol, V6, P47, DOI 10.1055/s-2002-23163
[9]
MR appearance of cartilage defects of the knee: preliminary results of a spiral CT arthrography-guided analysis [J].
Vande Berg, BC ;
Lecouvet, FE ;
Maldague, B ;
Malghem, J .
EUROPEAN RADIOLOGY, 2004, 14 (02) :208-214