Reagentless, reusable, ultrasensitive electrochemical molecular beacon aptasensor

被引:555
作者
Radi, AE [1 ]
Sánchez, JLA
Baldrich, E
O'Sullivan, CK
机构
[1] Mansoura Univ, Dept Chem, Fac Sci, Dumyat, Egypt
[2] Inst Catalan Recerca & Estudis Avancats, Barcelona 08010, Spain
[3] Univ Rovira & Virgili, Dept Chem Engn, Nanobiotechnol & Bioanal Grp, Tarragona, Spain
关键词
D O I
10.1021/ja053121d
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A bifunctional derivative of the thrombin-binding aptamer with a redox-active Fc moiety and a thiol group at-the termini of the aptamer strand was synthesized. The ferrocene-labeled aptamer thiol was self-assembled through S-Au bonding on a polycrystalline gold electrode surface and the surface was blocked with 2-mercaptoethanol to form a mixed monolayer. By use of a fluorescent molecular beacon, the effect of counterions on quadruplex formation was established. The aptamer-modified electrode was characterized electrochemically by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). The modified electrode showed a voltammetric signal due to a one-step redox reaction of the surface-confined ferrocenyl moiety of the aptamer immobilized on the electrode surface in 10 mM N-(2-hydroxyethyl) piperazine-N-2-ethanesulfonic acid (HEPES) buffer of pH 8.0. An increase in the DPV current signal was evident after blocking with 2-mercaptoethanol, effectively removing aptamer nonspecifically absorbed rather than bound to electrode surface or due to the formation of the aptamer-thrombin affinity interaction. The impedance measurement, in agreement with the differential pulse voltarnmetry (DPV), showed decreased Faradaic resistances in the same sequence. The "signal-on" upon thrombin association could be attributed to a change in conformation from random coil-like configuration on the probe-modified film to the quadruplex structure. The DPV of the modified electrode showed a linear response of the Fc oxidation signal to the increase in the thrombin concentration in the range between 5.0 and 35.0 nM with a linear correlation of r = 0.9988 and a detection limit of 0.5 nM. The molecular beacon aptasensor was amenable to full regeneration by simply unfolding the aptamer in 1.0 M HCl, and could be regenerated 25 times with no loss in electrochemical signal upon subsequent thrombin binding.
引用
收藏
页码:117 / 124
页数:8
相关论文
共 54 条
[1]   THE KINETICS OF ELECTRON-TRANSFER IN THE THIONINE-COATED ELECTRODE [J].
ALBERY, WJ ;
BOUTELLE, MG ;
COLBY, PJ ;
HILLMAN, AR .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1982, 133 (01) :135-145
[2]   Role of ion pairing in double-layer effects at self-assembled monolayers containing a simple redox couple [J].
Andreu, R ;
Calvente, JJ ;
Fawcett, WR ;
Molero, M .
JOURNAL OF PHYSICAL CHEMISTRY B, 1997, 101 (15) :2884-2894
[3]  
ANGERSTEINKOZLOWSKA H, 1977, J ELECTROANAL CHEM, V75, P45, DOI 10.1016/S0022-0728(77)80071-5
[4]   3′-ferrocene-labeled oligonucleotide chains end-tethered to gold electrode surfaces:: Novel model systems for exploring flexibility of short DNA using cyclic voltammetry [J].
Anne, A ;
Bouchardon, A ;
Moiroux, J .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (05) :1112-1113
[5]   In vitro selection of DNA aptamers on chips using a method for generating point mutations [J].
Asai, R ;
Nishimura, SI ;
Aita, T ;
Takahashi, K .
ANALYTICAL LETTERS, 2004, 37 (04) :645-656
[6]   Ability of thrombin to act as molecular chaperone, inducing formation of quadruplex structure of thrombin-binding aptamer [J].
Baldrich, E ;
O'Sullivan, CK .
ANALYTICAL BIOCHEMISTRY, 2005, 341 (01) :194-197
[7]  
BARD AJ, 1980, ELECTROCHEMICAL METH
[8]   Role of surface heterogeneity and molecular interactions in the charge-transfer process through self-assembled thiolate monolayers on Au(111) [J].
Benítez, G ;
Vericat, C ;
Tanco, S ;
Lenicov, FR ;
Castez, MF ;
Vela, AE ;
Salvarezza, RC .
LANGMUIR, 2004, 20 (12) :5030-5037
[9]   CYCLIC AND DIFFERENTIAL PULSE VOLTAMMETRIC BEHAVIOR OF REACTANTS CONFINED TO ELECTRODE SURFACE [J].
BROWN, AP ;
ANSON, FC .
ANALYTICAL CHEMISTRY, 1977, 49 (11) :1589-1595
[10]   In vitro selection of DNA aptamers to anthrax spores with electrochemiluminescence detection [J].
Bruno, JG ;
Kiel, JL .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) :457-464