Evaluation of COBAS AMPLICOR (Roche):: Accuracy in detection of Chlamydia trachomatis and Neisseria gonorrhoeae by coamplification of endocervical specimens

被引:26
作者
Livengood, CH [1 ]
Wrenn, JW [1 ]
机构
[1] Duke Univ, Med Ctr, Chlamydia Lab, Durham, NC USA
关键词
D O I
10.1128/JCM.39.8.2928-2932.2001
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
We evaluated further the accuracy of the COBAS AMPLICOR (Roche) (CA) PCR-based system in detection of Chlamydia trachomatis and Neisseria gonorrhoeae in endocervical specimens. Endocervical specimens collected for any indication for testing for C. trachomatis and N. gonorrhoeae among a university hospital health system population were included. Testing for C. trachomatis was done by two PCR methods, CA and manual microwell AMPLICOR (Roche) (MWA), and by culture; testing for N. gonorrhoeae was done by CA and culture. Discrepancy resolution was performed. Reproducibility testing and hands-on labor time measurements for CA were done. Among 654 C. trachomatis samples, the prevalence of true positivity was 9.2%, and among the 618 N. gonorrhoeae samples, the prevalence of true positivity was 4.4%. For detection of C. trachomatis, the sensitivity, specificity, and negative and positive predictive values were, respectively, as follows for each test: CA, 93.3, 99.7, 99.3, and 96.4%; MWA, 91.7, 99.7, 99.2, and 96.5%; and culture, 65.0, 100, 96.6, and 100%. For detection of N. gonorrhoeae those values were as follows: CA, 96.3, 100, 99.8, and 100%; and culture, 92.6, 100, 99.7, and 100%. Hands-on labor time for each clinical result was estimated to be at 7.5 min. The prevalence of inhibitory specimens was 3.5%, including two positive C. trachomatis samples which would have been missed otherwise. The direct cost of each clinical result with CA was estimated to be $9.09. Our methods include a diverse range of indications for testing among women, using endocervical swabbing samples, 2 M sucrose phosphate transport medium, and discrepancy resolution for comparison. Under our test conditions, the CA system is an accurate, rapid, and cost- and labor-efficient method for detection of C. trachomatis and N. gonorrhoeae.
引用
收藏
页码:2928 / 2932
页数:5
相关论文
共 16 条
[1]  
BIRD BR, 1980, LAB DIAGNOSIS CHLAMY, P39
[2]  
Boggess K. A., 1998, Primary Care Update for Ob/Gyns, V5, P114, DOI 10.1016/S1068-607X(98)00016-X
[3]  
*CDCP, 1998, MMWR-MORBID MORTAL W, V47, P53
[4]  
*CDCP, 1998, MMWR-MORBID MORTAL W, V47, P60
[5]   Detection of Neisseria gonorrhoeae and Chlamydia trachomatis in genitourinary specimens from men and women by a coamplification PCR assay [J].
Crotchfelt, KA ;
Welsh, LE ;
DeBonville, D ;
Rosenstraus, M ;
Quinn, TC .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (06) :1536-1540
[6]   Evaluation of 2-SP transport medium for detection of Chlamydia trachomatis and Neisseria gonorrhoeae by two automated amplification systems and culture for chlamydia [J].
Dubuis, O ;
GorgievskiHrisoho, M ;
Germann, D ;
Matter, L .
JOURNAL OF CLINICAL PATHOLOGY, 1997, 50 (11) :947-950
[7]   Evaluation of automated COBAS AMPLICOR PCR system for detection of several infectious agents and its impact on laboratory management [J].
Jungkind, D ;
DiRenzo, S ;
Beavis, KG ;
Silverman, NS .
JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (11) :2778-2783
[8]  
LIVENGOOD CH, 1988, OBSTET GYNECOL, V72, P803
[9]  
LIVENGOOD CH, 1988, DIS OBSTET GYNECOL, V6, P224
[10]  
SCHACHTER J, 1985, YALE J BIOL MED, V58, P443