Evaluation of a novel anion-exchange restricted-access sorbent for on-line sample clean-up prior to the determination of acidic compounds in plasma by liquid chromatography

被引:38
作者
Rbeida, O
Christiaens, B
Hubert, P
Lubda, D
Boos, KS
Crommen, J
Chiap, P
机构
[1] Univ Liege, CHU, Inst Pharm, Dept Pharmaceut Analyt Chem, B-4000 Liege 1, Belgium
[2] Merck KGaA LSP, D-64271 Darmstadt, Germany
[3] Univ Hosp Grosshadern, Inst Clin Chem, D-81366 Munich, Germany
关键词
restricted-access media; sample preparation; column-switching; acidic drugs; amino acids; ascorbic acid; acetylcysteine;
D O I
10.1016/j.chroma.2003.11.031
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new kind of silica-based restricted-access material (RAM) with anionic properties has been tested in pre-columns for on-line solid-phase extraction of acidic compounds from directly injected plasma samples prior to their determination by reversed-phase liquid chromatography (LC), using the column-switching technique. The outer surface of the porous RAM particles contains hydrophilic diol groups while diethylaminoethyl (DEAE) groups are bound to the internal surface which gives the sorbent the properties of a weak anion exchanger towards low-molecular-mass compounds. Due to an appropriate pore diameter (about 6 nm), macromolecules, such as proteins, are physically excluded from the pores and flushed directly out during the sample clean-up process, while small compounds have access to the inner surface and can be retained mainly by electrostatic interactions. The retention capability of this novel packing material has been tested for some hydrophilic acidic compounds such as aspartic acid, glutamic acid, ascorbic acid and acetylcysteine as well as for some more hydrophobic drugs such as naproxen, ibuprofen and diclofenac, used as model compounds. The influence of the composition of the washing liquid on the retention of the analytes in the pre-column has been investigated. The efficiency of the sorbent to clean-up complex matrices was also tested using human plasma and urine samples. A generic washing liquid composition was then selected in order to obtain efficient and selective sample clean-up as well as a high recovery of the acidic analytes. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:95 / 102
页数:8
相关论文
共 27 条
[1]   Trace determination of priority pesticides in water by means of high-speed on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry using turbulent-flow chromatography columns for enrichment and a short monolithic column for fast liquid chromatographic separation [J].
Asperger, A ;
Efer, J ;
Koal, T ;
Engewald, W .
JOURNAL OF CHROMATOGRAPHY A, 2002, 960 (1-2) :109-119
[2]   Application of the restricted-access precolumn packing material alkyl-diol silica in a column-switching system for the determination of ketoprofen enantiomers in horse plasma [J].
Baeyens, WRG ;
Van der Weken, G ;
Haustraete, J ;
Aboul-Enein, HY ;
Corveleyn, S ;
Remon, JP ;
García-Campaña, AM ;
Deprez, P .
JOURNAL OF CHROMATOGRAPHY A, 2000, 871 (1-2) :153-161
[3]   High-performance liquid chromatography integrated solid-phase extraction in bioanalysis using restricted access precolumn packings [J].
Boos, KS ;
Grimm, CH .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (03) :175-180
[4]   ALKYL-DIOL SILICA (ADS) - RESTRICTED ACCESS PRECOLUMN PACKINGS FOR DIRECT-INJECTION AND COUPLED-COLUMN CHROMATOGRAPHY OF BIOFLUIDS [J].
BOOS, KS ;
RUDOLPHI, A ;
VIELHAUER, S ;
WALFORT, A ;
LUBDA, D ;
EISENBEISS, F .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (7-8) :684-690
[5]   High-performance liquid chromatographic determination of cocaine and benzoylecgonine by direct injection of human blood plasma sample into an alkyl-diol-silica (ADS) precolumn [J].
Brunetto, R ;
Gutiérrez, L ;
Delgado, Y ;
Gallignani, M ;
Burguera, JL ;
Burguera, M .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (04) :534-538
[6]   Simultaneous determination of methylphenobarbital enantiomers and phenobarbital in human plasma by on-line coupling of an achiral precolumn to a chiral liquid chromatographic column [J].
Ceccato, A ;
Boulanger, B ;
Chiap, P ;
Hubert, P ;
Crommen, J .
JOURNAL OF CHROMATOGRAPHY A, 1998, 819 (1-2) :143-153
[7]  
Chassaing C, 2001, CHROMATOGRAPHIA, V53, P122
[8]   Use of a novel cation-exchange restricted-access material for automated sample clean-up prior to the determination of basic drugs in plasma by liquid chromatography [J].
Chiap, P ;
Rbeida, O ;
Christiaens, B ;
Hubert, P ;
Lubda, D ;
Boos, KS ;
Crommen, J .
JOURNAL OF CHROMATOGRAPHY A, 2002, 975 (01) :145-155
[9]   Automated determination of pirlindole enantiomers in plasma by on-line coupling of a pre-column packed with restricted access material to a chiral liquid chromatographic column [J].
Chiap, P ;
Ceccato, A ;
Gora, R ;
Hubert, P ;
Géczy, J ;
Crommen, J .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 27 (3-4) :447-455
[10]   Direct analysis of artemisinin in plasma and saliva using coupled-column high-performance liquid chromatography with a restricted-access material pre-column [J].
Gordi, T ;
Nielsen, E ;
Yu, ZX ;
Westerlund, D ;
Ashton, M .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 742 (01) :155-162