Paclitaxel-coated balloon in combination with bare metal stent for treatment of de novo coronary lesions: an optical coherence tomography first-in-human randomised trial, balloon first vs. stent first

被引:35
作者
Gutierrez-Chico, Juan Luis [1 ]
van Geuns, Robert Jan [1 ]
Koch, Karel T. [2 ]
Koolen, Jacques J. [3 ]
Duckers, Henricus [1 ]
Regar, Evelyn [1 ]
Serruys, Patrick W. [1 ]
机构
[1] Erasmus MC, Thoraxctr, NL-3015 CE Rotterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, NL-1105 AZ Amsterdam, Netherlands
[3] Catharina Hosp, Eindhoven, Netherlands
关键词
coronary stenosis; angioplasty; drug-coat balloon; paclitaxel; optical coherence tomography; DRUG-ELUTING STENTS; CONTRAST-MEDIA; STRUT COVERAGE; RESTENOSIS; THROMBOSIS; IMPLANTATION; ARTERIES; INHIBITION; CATHETER; DELIVERY;
D O I
10.4244/EIJV7I6A114
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To test the efficacy of sequential application of drug-coated balloon (DCB) and bare metal stent (BMS) for treatment of de novo coronary lesions, comparing the sequence of application (DCB first vs. BMS first). Methods and results: In a multicentre pilot trial, 26 patients with de 1101,0 coronary lesions were randomised to receive a paclitaxel-coated balloon application followed by BMS implantation (DCB first) or vice versa (BMS first). Quantitative coronary angiography (QCA) and optical coherence tomography (OCT) were performed post-procedure and at six months, with OCT % neointimal volume obstruction as primary endpoint. Longitudinal geographical miss was only observed in DCB first (23.1 vs. 0.0%, p=0.220). Implantation of BM S first resulted in fewer malapposed struts (p=0.013) but similar coverage at six months. No significant difference was found regarding the primary endpoint (25.5 vs. 24.9%, p=0.922), mean thickness of coverage (261 vs. 2251.1m, p=0.763), late loss (0.53 vs. 0.45 mm, p=0.833), binary restenosis (27.3 vs. 16.7% in-segment, p=0.640) or clinical endpoints. Conclusions: Sequential application of DCB and not pre-mounted BMS for treatment of de novo coronary lesions results in efficient inhibition of neointimal hyperplasia. The sequence of application (DCB first vs. BMS first) does not seem to influence the outcome, except for better apposition in BMS first.
引用
收藏
页码:711 / 722
页数:12
相关论文
共 25 条
[1]   Correlation of Intravascular Ultrasound Findings With Histopathological Analysis of Thrombus Aspirates in Patients With Very Late Drug-Eluting Stent Thrombosis [J].
Cook, Stephane ;
Ladich, Elena ;
Nakazawa, Gaku ;
Eshtehardi, Parham ;
Neidhart, Michel ;
Vogel, Rolf ;
Togni, Mario ;
Wenaweser, Peter ;
Billinger, Michael ;
Seiler, Christian ;
Gay, Steffen ;
Meier, Bernhard ;
Pichler, Werner J. ;
Jueni, Peter ;
Virmani, Renu ;
Windecker, Stephan .
CIRCULATION, 2009, 120 (05) :391-399
[2]   Arterial paclitaxel distribution and deposition [J].
Creel, CJ ;
Lovich, MA ;
Edelman, ER .
CIRCULATION RESEARCH, 2000, 86 (08) :879-884
[3]   Pathological mechanisms of fatal late coronary stent thrombosis in humans [J].
Farb, A ;
Burke, AP ;
Kolodgie, FD ;
Virmani, R .
CIRCULATION, 2003, 108 (14) :1701-1706
[4]   Pathological correlates of late drug-eluting stent thrombosis - Strut coverage as a marker of endothelialization [J].
Finn, Aloke V. ;
Joner, Michael ;
Nakazawa, Gaku ;
Kolodgie, Frank ;
Newell, John ;
John, Mike C. ;
Gold, Herman K. ;
Virmani, Renu .
CIRCULATION, 2007, 115 (18) :2435-2441
[5]  
GARG S, 2010, CURRENT, V56, P1
[6]   Second-Generation Optical Coherence Tomography in Clinical Practice. High-Speed Data Acquisition Is Highly Reproducible in Patients Undergoing Percutaneous Coronary Intervention [J].
Gonzalo, Nieves ;
Tearney, Guillermo J. ;
Serruys, Patrick W. ;
van Soest, Gijs ;
Okamura, Takayuki ;
Garcia-Garcia, Hector M. ;
Jan van Geuns, Robert ;
van der Ent, Martin ;
Ligthart, Jurgen ;
Bouma, Brett E. ;
Regar, Evelyn .
REVISTA ESPANOLA DE CARDIOLOGIA, 2010, 63 (08) :893-903
[7]   Reproducibility of quantitative optical coherence tomography for stent analysis [J].
Gonzalo, Nieves ;
Garcia-Garcia, Hector M. ;
Serruys, Patrick W. ;
Commissaris, Koen H. ;
Bezerra, Hiram ;
Gobbens, Pierre ;
Costa, Marco ;
Regar, Evelyn .
EUROINTERVENTION, 2009, 5 (02) :224-232
[8]   CAAS-II - A 2ND GENERATION SYSTEM FOR OFF-LINE AND ONLINE QUANTITATIVE CORONARY ANGIOGRAPHY [J].
GRONENSCHILD, E ;
JANSSEN, J ;
TIJDENS, F .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 33 (01) :61-75
[9]   Strut Coverage and Vessel Wall Response to a New-Generation Paclitaxel-Eluting Stent With an Ultrathin Biodegradable Abluminal Polymer Optical Coherence Tomography Drug-Eluting Stent Investigation (OCTDESI) [J].
Guagliumi, Giulio ;
Sirbu, Vasile ;
Musumeci, Giuseppe ;
Bezerra, Hiram G. ;
Aprile, Alessandro ;
Kyono, Hiroyuki ;
Fiocca, Luigi ;
Matiashvili, Aleksandre ;
Lortkipanidze, Nikoloz ;
Vassileva, Angelina ;
Popma, Jeffrey J. ;
Allocco, Dominic J. ;
Dawkins, Keith D. ;
Valsecchi, Orazio ;
Costa, Marco A. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (04) :367-U154
[10]   Optical Coherence Tomography Assessment of In Vivo Vascular Response After Implantation of Overlapping Bare-Metal and Drug-Eluting Stents [J].
Guagliumi, Giulio ;
Musumeci, Giuseppe ;
Sirbu, Vasile ;
Bezerra, Hiram G. ;
Suzuki, Nobuaki ;
Fiocca, Luigi ;
Matiashvili, Aleksandre ;
Lortkipanidze, Nikoloz ;
Trivisonno, Antonio ;
Valsecchi, Orazio ;
Biondi-Zoccai, Giuseppe ;
Costa, Marco A. .