Room chamber assessment of the pollutant emission properties of (nominally) low-emission unflued gas heaters

被引:12
作者
Brown, SK [1 ]
Mahoney, KJ [1 ]
Cheng, M [1 ]
机构
[1] CSIRO Mfg & Infrastruct Technol, Highett, Vic 3190, Australia
关键词
carbon monoxide; formaldehyde; indoor air; gas heater; nitrogen dioxide; pollutant emission; unflued; unvented;
D O I
10.1111/j.1600-0668.2004.00296.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Pollutant emissions from unflued gas heaters were assessed in CSIRO's Room Dynamic Environmental Chamber. This paper describes the chamber assessment procedure and presents findings for major commercial heaters that are nominally "low-emission". The chamber was operated at controlled conditions of temperature, humidity, ventilation and air mixing, representative of those encountered in typical indoor environments. A fixed rate of heat removal from the chamber air ensured that the heaters operated at constant heating rates, typically similar to6 MJ/h which simulated operation of a heater after warm-up in an insulated dwelling in south-east Australia. The pollutants assessed were nitrogen dioxide, carbon monoxide, formaldehyde, VOCs and respirable suspended particulates. One type of heater was lower emitting for nitrogen dioxide, but emitted greater amounts of carbon monoxide and formaldehyde (the latter becoming significant to indoor air quality). When operated with low line pressure or slight misalignment of the gas burner, this heater became a hazardous source of these pollutants. Emissions from the heaters changed little after continuous operation for up to 2 months.
引用
收藏
页码:84 / 91
页数:8
相关论文
共 20 条
[1]  
[Anonymous], 2001, D667001 ASTM
[2]  
APTE MG, 1989, LBL26306
[3]  
*ASTM, 1995, E74195 ASTM
[4]   MEASUREMENTS OF NITROUS-ACID INSIDE 2 RESEARCH HOUSES [J].
BRAUER, M ;
RYAN, PB ;
SUH, HH ;
KOUTRAKIS, P ;
SPENGLER, JD ;
LESLIE, NP ;
BILLICK, IH .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1990, 24 (10) :1521-1527
[5]   Assessment of pollutant emissions from dry-process photocopiers [J].
Brown, SK .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1999, 9 (04) :259-267
[6]  
BROWN SK, 1997, STATE ENV TECHNICAL
[7]  
CAMPBELL RM, 1995, INDOOR AIR INTEGRATE, P301
[8]  
CHRISTIANSON LL, 1989, BUILDING SYSTEMS ROO, P218
[9]  
DEWERTH DW, 1996, GRI960093
[10]  
DURET MJ, 1990, GRI900164