Single-centre experience with coronary sinus lead stability and tong-term pacing parameters

被引:28
作者
Bulava, Alan [1 ]
Luki, Jan [1 ]
机构
[1] Univ Hosp, Dept Internal Med, Olomouc, Czech Republic
来源
EUROPACE | 2007年 / 9卷 / 07期
关键词
CS lead stability; long-term performance; biventricutar pacing;
D O I
10.1093/europace/eum082
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To compare both short- and long-term stability and pacing parameters of CS leads. Long-term maintenance of coronary sinus (CS) pacing lead position has not yet been assessed by serial X-ray digital imaging. Methods and results Using X-ray digital imaging in anteroposterior and left lateral views, we performed analysis of the CS lead position at the end of the implantation procedure, 48 h following implantation and after 12 months in 93 consecutive patients. Attain OTW leads, QuickSite leads and EasyTrak leads were implanted in 44, 12 and 37 cases, respectively. X-ray detectable late CS lead dislodgement was observed in 8 cases (8.6%) during 12-months follow-up. Dislodgment was once accompanied by toss of capture and need for repositioning. Another two major dislodgements occurred without any threshold change. Five (5.4%) minor dislocations occurred with either a decrease or an increase in pacing threshold. Left ventricular (LV) pacing threshold was changed by >= 1 V after 12 months in 14 patients (15%) when compared to values 48 h after implantation. All but one case of >= 1 V threshold change (either positive or negative) occurred without any radiological evidence of lead displacement. IV pacing threshold was significantly higher than RV pacing threshold at both baseline and during follow-up. Leads from all three manufacturers had comparable pacing thresholds 12 months following implantation. Conclusion The position of CS leads may change during 1-year follow-up. However, it rarely required reoperation in the selected group of patients. Long-term pacing parameters between different manufacturers are comparable. Increase in pacing threshold is not a reliable marker of CS lead dislodgement.
引用
收藏
页码:523 / 527
页数:5
相关论文
共 8 条
  • [1] Cardiac resynchronization in chronic heart failure
    Abraham, WT
    Fisher, WG
    Smith, AL
    Delurgio, DB
    Leon, AR
    Loh, E
    Kocovic, DZ
    Packer, M
    Clavell, AL
    Hayes, DL
    Ellestad, M
    Messenger, J
    Trupp, RJ
    Underwood, J
    Pickering, F
    Truex, C
    McAtee, P
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (24) : 1845 - 1853
  • [2] Six year experience of transvenous left ventricular lead implantation for permanent biventricular pacing in patients with advanced heart failure: technical aspects
    Alonso, C
    Leclercq, C
    d'Allonnes, FR
    Pavin, D
    Victor, F
    Mabo, P
    Daubert, JC
    [J]. HEART, 2001, 86 (04) : 405 - 410
  • [3] Effect of resynchronization therapy stimulation site on the systolic function of heart failure patients
    Butter, C
    Auricchio, A
    Stellbrink, C
    Fleck, E
    Ding, J
    Yu, YH
    Huvelle, E
    Spinelli, J
    [J]. CIRCULATION, 2001, 104 (25) : 3026 - 3029
  • [4] The effect of cardiac resynchronization on morbidity and mortality in heart failure
    Cleland, JGF
    Daubert, J
    Erdmann, E
    Freemantle, N
    Gras, D
    Kappenberger, L
    Tavazzi, L
    Cleland, JGF
    Daubert, JC
    Erdmann, E
    Gras, D
    Kappenberger, L
    Klein, W
    Tavazzi, L
    Poole-Wilson, PA
    Rydén, L
    Wedel, H
    Wellens, HJJ
    Uretsky, B
    Thygesen, K
    Böcker, D
    Marijianowski, MMH
    Freemantle, N
    Calvert, MJ
    Christ, G
    Fruhwald, F
    Hofmann, R
    Krypta, A
    Leisch, F
    Pacher, R
    Rauscha, F
    Tavernier, R
    Thomsen, PEB
    Boesgaard, S
    Eiskjær, H
    Esperen, GT
    Haarbo, J
    Hagemann, A
    Korup, E
    Moller, M
    Mortensen, P
    Sogaard, P
    Vesterlund, T
    Huikuri, H
    Niemelä, KI
    Toivonen, L
    Bauer, F
    Cohen-Solal, A
    Crocq, C
    Djiane, P
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (15) : 1539 - 1549
  • [5] Safety of transvenous cardiac resynchronization system implantation in patients with chronic heart failure -: Combined results of over 2,000 patients from a multicenter study program
    León, AR
    Abraham, WT
    Curtis, AB
    Daubert, JP
    Fisher, WG
    Gurley, J
    Hayes, DL
    Lieberman, R
    Petersen-Stejskal, S
    Wheelan, K
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (12) : 2348 - 2356
  • [6] Ricci R, 2000, EUR HEART J SUPPL, V2, pJ6
  • [7] Comparison of medical therapy, pacing and defibrillation in heart failure (COMPANION) trial terminated early; combined biventricular pacemaker-defibrillators reduce all-cause mortality and hospitalization
    Salukhe, TV
    Francis, DP
    Sutton, R
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2003, 87 (2-3) : 119 - 120
  • [8] Adverse events with transvenous left ventricular pacing in patients with severe heart failure: early experience from a single centre
    Valls-Bertault, V
    Mansourati, J
    Gilard, M
    Etienne, Y
    Munier, S
    Blanc, JJ
    [J]. EUROPACE, 2001, 3 (01): : 60 - 63