Comparison of adenosine and high-dose dipyridamole both combined with low-level exercise stress for Tc-99(m)-MIBI SPET myocardial perfusion imaging

被引:19
作者
Cramer, MJM [1 ]
Verzijlbergen, JF [1 ]
VanderWall, EE [1 ]
Vermeersch, PH [1 ]
Niemeyer, MG [1 ]
Zwinderman, AH [1 ]
Ascoop, CA [1 ]
Pauwels, EKJ [1 ]
机构
[1] ST ANTONIUS HOSP, DEPT CARDIOL, NIEUWEGEIN, NETHERLANDS
关键词
D O I
10.1097/00006231-199602000-00002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Intravenously administered adenosine and high-dose dipyridamole, both combined with low-level exercise stress, were compared in a head-to-head fashion using Tc-99(m)-methoxyisobutyl isonitrile (Tc-99(m)-MIBI) single photo emission tomography (SPET) myocardial perfusion imaging. Thirty-nine consecutive patients who had undergone coronary arteriography underwent Tc-99(m)-MIBI (740 Mbq) SPET after dipyridamole (0.84 mg kg(-1)) and after adenosine (0.84 mg kg(-1)), both combined with low-level exercise (30 W load), and under resting conditions. Our results demonstrate that adenosine and dipyridamole combined with exercise have comparable haemodynamic effects, with a low incidence of side-effects. The time of recovery from the stress protocol was not significantly different: adenosine, 5.7 +/- 3.9 min; dipyridamole, 6.6 +/- 4.9 min. However, aminophylline was significantly (P < 0.05) more often administered to reverse side-effects using the dipyridamole protocol (36% of patients) compared with the adenosine protocol (8% of patients). The results of Tc-99(m)-MIBI SPET imaging were highly concordant and demonstrated a high diagnostic accuracy for identifying coronary artery disease (CAD). The sensitivity was 90% (95% confidence intervals 79-100%) with adenosine SPET and 93% (95% confidence intervals 84-100%) with dipyridamole SPET for identifying patients with CAD (i.e. luminal stenosis > 50%); their specificities were both 100% (95% confidence intervals 66-100%). The sensitivity of identifying angiographically diseased vessels was 81% (95% confidence intervals 70-92%) using adenosine SPET and 85% (95% confidence intervals 75-95%) using dipyridamole; the specificity for both stress modalities was 94% (95% confidence intervals 89-100%). The combination of exercise with adenosine and high-dose dipyridamole appears to be a feasible and safe method to alleviate some of the undesirable A1-receptor-mediated side-effects of adenosine. The choice of the pharmacological stress will depend on local expertise and availability.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 44 条
[21]  
LALONDE D, 1994, J NUCL MED, V35, P1245
[22]   SAFETY AND DIAGNOSTIC-ACCURACY OF DIPYRIDAMOLE-THALLIUM IMAGING IN THE ELDERLY [J].
LAM, JYT ;
CHAITMAN, BR ;
GLAENZER, M ;
BYERS, S ;
FITE, J ;
SHAH, Y ;
GOODGOLD, H ;
SAMUELS, L .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (03) :585-589
[23]   ATRIOVENTRICULAR-BLOCK DURING ADENOSINE THALLIUM IMAGING [J].
LEE, J ;
HEO, JY ;
OGILBY, JD ;
CAVE, V ;
ISKANDRIAN, B ;
ISKANDRIAN, AS .
AMERICAN HEART JOURNAL, 1992, 123 (06) :1569-1574
[24]   DIPYRIDAMOLE-THALLIUM-201 SCINTIGRAPHY IN THE PREDICTION OF FUTURE CARDIAC EVENTS AFTER ACUTE MYOCARDIAL-INFARCTION [J].
LEPPO, JA ;
OBRIEN, J ;
ROTHENDLER, JA ;
GETCHELL, JD ;
LEE, VW .
NEW ENGLAND JOURNAL OF MEDICINE, 1984, 310 (16) :1014-1018
[25]   ELECTROPHYSIOLOGIC EFFECTS OF DIPYRIDAMOLE ON ATRIOVENTRICULAR NODAL CONDUCTION AND SUPRAVENTRICULAR TACHYCARDIA - ROLE OF ENDOGENOUS ADENOSINE [J].
LERMAN, BB ;
WESLEY, RC ;
BELARDINELLI, L .
CIRCULATION, 1989, 80 (06) :1536-1543
[26]   SAFETY OF DIPYRIDAMOLE TESTING IN 73,806 PATIENTS - THE MULTICENTER DIPYRIDAMOLE SAFETY STUDY [J].
LETTE, J ;
TATUM, JL ;
FRASER, S ;
MILLER, DD ;
WATERS, DD ;
HELLER, G ;
STANTON, EB ;
BOM, HS ;
LEPPO, J ;
NATTEL, S .
JOURNAL OF NUCLEAR CARDIOLOGY, 1995, 2 (01) :3-17
[27]   TURNOVER OF ADENOSINE IN PLASMA OF HUMAN AND DOG-BLOOD [J].
MOSER, GH ;
SCHRADER, J ;
DEUSSEN, A .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 256 (04) :C799-C806
[28]   4-MINUTE VERSUS 8-MINUTE INFUSION PROTOCOL FOR ADENOSINE TL-201 SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY IMAGING [J].
OKEEFE, JH ;
BATEMAN, TM ;
HANDLIN, LR ;
BARNHART, CS .
AMERICAN HEART JOURNAL, 1995, 129 (03) :482-487
[29]   ACCURACY AND SAFETY OF TC-99M HEXAKIS 2-METHOXY-2-ISOBUTYL ISONITRILE (SESTAMIBI) MYOCARDIAL SCINTIGRAPHY WITH HIGH-DOSE DIPYRIDAMOLE TEST IN PATIENTS WITH EFFORT ANGINA-PECTORIS - A MULTICENTER STUDY [J].
PARODI, O ;
MARCASSA, C ;
CASUCCI, R ;
SAMBUCETI, G ;
VERNA, E ;
GALLI, M ;
INGLESE, E ;
MARZULLO, P ;
PIRELLI, S ;
BISI, G ;
GIUBBINI, R ;
SCOPINARO, F .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (06) :1439-1444
[30]   ADENOSINE COMBINED WITH DYNAMIC EXERCISE FOR MYOCARDIAL PERFUSION IMAGING [J].
PENNELL, DJ ;
MAVROGENI, SI ;
FORBAT, SM ;
KARWATOWSKI, SP ;
UNDERWOOD, SR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (06) :1300-1309