Arrayed time-of-flight mass spectrometry for time-critical detection of hazardous agents

被引:35
作者
Cornish, TJ [1 ]
Antoine, MD [1 ]
Ecelberger, SA [1 ]
Demirev, PA [1 ]
机构
[1] Johns Hopkins Univ, Appl Phys Lab, Laurel, MD 20723 USA
关键词
D O I
10.1021/ac0500939
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The design and operation of an arrayed time-of-flight (TOF) mass spectrometer for simultaneous data acquisition from multiple samples is described. Versions of the instrument employ sets of two or four linear or reflectron mass analyzers. They are housed in the same vacuum chamber and utilize the same laser for ion desorption. Instrument performance is illustrated in the example of a two-linear-mass-analyzer array using MALDI-MS for mixtures of commercially available proteins as well as intact microorganisms. We also describe the properties of a novel short delay time (< 170 ns) pulsed extraction method for linear TOF analyzers. This configuration allows uniform resolution improvements to be achieved in a wide m/z range. In addition, we present multiplexed sample preparation methods, using different reagents prior to mass analysis in the arrayed system, to increase the overall sensitivity of the MS method and to allow wider and more efficient detection across the entire range of potentially hazardous agents. In addition to the multifold increase in data collection rates, arrayed TOF-MS configurations provide a high degree of redundancy, critical for rapid, high confidence agent identification as well as for reduction in false alarm rates.
引用
收藏
页码:3954 / 3959
页数:6
相关论文
共 47 条
  • [1] Anderson CW, 1999, J HOPKINS APL TECH D, V20, P352
  • [2] Antoine MD, 2004, J HOPKINS APL TECH D, V25, P20
  • [3] Badman ER, 2000, J MASS SPECTROM, V35, P659, DOI 10.1002/1096-9888(200006)35:6<659::AID-JMS5>3.0.CO
  • [4] 2-V
  • [5] Evaluation of the variables that affect resolution in delayed extraction MALDI-TOF
    Barbacci, DC
    Edmondson, RD
    Russell, DH
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1997, 165 : 221 - 235
  • [6] Towards the hand-held mass spectrometer: design considerations, simulation, and fabrication of micrometer-scaled cylindrical ion traps
    Blain, MG
    Riter, LS
    Cruz, D
    Austin, DE
    Wu, GX
    Plass, WR
    Cooks, RG
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 236 (1-3) : 91 - 104
  • [7] Miniature time-of-flight mass spectrometers for in situ composition studies
    Brinckerhoff, WB
    Cornish, TJ
    McEntire, RW
    Cheng, AF
    Benson, RC
    [J]. ACTA ASTRONAUTICA, 2003, 52 (2-6) : 397 - 404
  • [8] Characterization of a Hadamard transform time-of-flight mass spectrometer
    Brock, A
    Rodriguez, N
    Zare, RN
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (03) : 1306 - 1318
  • [9] MASS RESOLUTION IMPROVEMENT BY INCORPORATION OF PULSED ION EXTRACTION IN A MATRIX-ASSISTED LASER-DESORPTION IONIZATION LINEAR TIME-OF-FLIGHT MASS-SPECTROMETER
    BROWN, RS
    LENNON, JJ
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (13) : 1998 - 2003
  • [10] Bryden WA, 1997, J HOPKINS APL TECH D, V18, P302