Brain γ-aminobutyric acid measurement by proton double-quantum filtering with selective J rewinding

被引:22
作者
Choi, CH
Coupland, NJ
Hanstock, CC
Ogilvie, CJ
Higgins, ACM
Gheorghiu, D
Allen, PS
机构
[1] Univ Alberta, Dept Biomed Engn, Edmonton, AB T6G 2G3, Canada
[2] Univ Alberta, Dept Psychiat, Edmonton, AB, Canada
关键词
gamma-aminobutyric acid (GABA); human brain; double-quantum filter; double-resonance selective refocusing; prefrontal cortex;
D O I
10.1002/mrm.20563
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An optimized single-shot proton double-quantum (DO) filter for the quantification of gamma-aminobutyric acid (GABA) levels in human brain is reported. It is demonstrated that creation of DO coherences following dual-resonance-selective refocusing gives a theoretical editing efficiency of 50% for the detection of the GABA resonance at 3.01 ppm. The sequence times are optimized with both numerical and experimental analyses of the editing performance, giving an experimental editing efficiency of 42%. It is acknowledged that homocarnosine is partially coedited, leading to a 20% contribution to the edited signal; however, macromolecule contamination is negligible in vivo under these experimental conditions. The GABA concentration in human prefrontal cortex is estimated to be 0.8 +/- 0.1 mu mol/g (mean +/- SD, n = 6), with reference to the internal standard creatine at 9 mu mol/g.
引用
收藏
页码:272 / 279
页数:8
相关论文
共 30 条
[1]   ANALYSIS OF MACROMOLECULE RESONANCES IN H-1-NMR SPECTRA OF HUMAN BRAIN [J].
BEHAR, KL ;
ROTHMAN, DL ;
SPENCER, DD ;
PETROFF, OAC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :294-302
[2]   Single-shot two-echo technique for simultaneous measurement of GABA and creatine in the human brain in vivo [J].
Choi, IY ;
Lee, SP ;
Merkle, H ;
Shen, J .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (06) :1115-1121
[3]   Detection of γ-aminobutyric acid (GABA) by longitudinal scalar order difference editing [J].
de Graaf, RA ;
Rothman, DL .
JOURNAL OF MAGNETIC RESONANCE, 2001, 152 (01) :124-131
[4]  
ERNST RR, 1987, PRINICPLES NUCL MAGN
[5]  
Govindaraju V, 2000, NMR BIOMED, V13, P129, DOI 10.1002/1099-1492(200005)13:3<129::AID-NBM619>3.0.CO
[6]  
2-V
[7]  
GREEN H, 1989, J MAGN RESON, V81, P646
[8]   AUTOMATIC, LOCALIZED INVIVO ADJUSTMENT OF ALL 1ST-ORDER AND 2ND-ORDER SHIM COILS [J].
GRUETTER, R .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) :804-811
[9]  
Henry PG, 2001, MAGNET RESON MED, V45, P517, DOI 10.1002/1522-2594(200103)45:3<517::AID-MRM1068>3.0.CO
[10]  
2-6