Dispersive liquid-liquid microextraction combined with semi-automated in-syringe back extraction as a new approach for the sample preparation of ionizable organic compounds prior to liquid chromatography

被引:73
作者
Melwanki, Mahaveer B. [1 ]
Fuh, Ming-Ren [1 ]
机构
[1] Soochow Univ, Dept Chem, Taipei 111, Taiwan
关键词
dispersive liquid-liquid microextraction; in-syringe back extraction; ionizable organic compounds; liquid chromatography;
D O I
10.1016/j.chroma.2008.05.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Dispersive liquid-liquid microextraction (DLLME) followed by a newly designed semi-automated in-syringe back extraction technique has been developed as an extraction methodology for the extraction of polar organic compounds prior to liquid chromatography (LC) measurement. The method is based on the formation of tiny droplets of the extractant in the sample solution using water-immiscible organic solvent (extractant) dissolved in a water-miscible organic dispersive solvent. Extraction of the analytes from aqueous sample into the dispersed organic droplets took place. The extracting organic phase was separated by centrifuging and the sedimented phase was withdrawn into a syringe. Then in-syringe back extraction was utilized to extract the analytes into an aqueous solution prior to LC analysis. Clenbuterol (CB), a basic organic compound used as a model, was extracted from a basified aqueous sample using 25 mu L tetrachloroethylene (TCE, extraction solvent) dissolved in 500 mu L acetone (as a dispersive solvent). After separation of the organic extracting phase by centrifuging, CB enriched in TCE phase was back extracted into 10 mu L of 1% aqueous formic acid (FA) within the syringe. Back extraction was facilitated by repeatedly moving the plunger back and forth within the barrel of syringe, assisted by a syringe pump. Due to the plunger movement, a thin organic film is formed on the inner layer of the syringe that comes in contact with the acidic aqueous phase. Here, CB, a basic analyte, will be protonated and back extracted into FA. Various parameters affecting the extraction efficiency, viz., choice of extraction and dispersive solvent, salt effect, speed of syringe pump, back extraction time period, effect of concentration of base and acid, were evaluated. Under optimum conditions, precision, linearity (correlation coefficient, r(2) = 0.9966 over the concentration range of 10-1000 ng mL(-1) CB), detection limit (4.9 ng mL(-1)), enrichment factor (175), relative recovery (97%) had been obtained. The applicability of this newly developed method was investigated for the analysis of CB in the water samples from river, lake and stream water. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 25 条
[1]   Determination of organophosphorus pesticides in water samples by single drop microextraction and gas chromatography-flame photometric detector [J].
Ahmadi, F ;
Assadi, Y ;
Hosseini, SMRM ;
Rezaee, M .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1101 (1-2) :307-312
[2]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[3]   Simultaneous high-throughput determination of clenbuterol, ambroxol and bromhexine in pharmaceutical formulations by HPLC with potentiometric detection [J].
Bazylak, G ;
Nagels, LJ .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (4-5) :887-903
[4]   Dispersive liquid-liquid microextraction combined with gas chromatography-flame photometric detection - Very simple, rapid and sensitive method for the determination of organophosphorus pesticides in water [J].
Berijani, Sana ;
Assadi, Yaghoub ;
Anbia, Mansoor ;
Milani Hosseini, Mohammad-Reza ;
Aghaee, Elham .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1123 (01) :1-9
[5]   Simultaneous derivatization and extraction of anilines in waste water with dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometric detection [J].
Chiang, Jing-Shan ;
Huang, Shang-Da .
TALANTA, 2008, 75 (01) :70-75
[6]   Solid-phase micro extraction (SPME) and headspace derivatization of clenbuterol followed by GC-FID and GC-SIMMS quantification [J].
Engelmann, MD ;
Hinz, D ;
Wenclawiak, BW .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (05) :460-464
[7]   Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-diode array detection as an efficient and sensitive technique for determination of antioxidants [J].
Farajzadeh, Mir Ali ;
Bahram, Morteza ;
Jonsson, Jan Ake .
ANALYTICA CHIMICA ACTA, 2007, 591 (01) :69-79
[8]   Determination of volatile phenols in red wines by dispersive liquid-liquid microextraction and gas chromatography-mass spectrometry detection [J].
Farina, Laura ;
Boido, Eduardo ;
Carrau, Francisco ;
Dellacassa, Eduardo .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1157 (1-2) :46-50
[9]   Determination of chlorophenols in water samples using simultaneous dispersive liquid-liquid microextraction and derivatization followed by gas chromatography-electron-capture detection [J].
Fattahi, Nazir ;
Assadi, Yaghoub ;
Hosseini, Mohammad Reza Milani ;
Jahromi, Elham. Zeini .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1157 (1-2) :23-29
[10]   Development of a dispersive liquid-liquid microextraction method for organophosphorus flame retardants and plastizicers determination in water samples [J].
Garcia-Lopez, M. ;
Rodriguez, I. ;
Cela, R. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1166 (1-2) :9-15