Rapid monitoring of arrays of amino acids in clinical samples using capillary electrophoresis with contactless conductivity detection

被引:71
作者
Tuma, Petr [1 ]
Malkova, Klara [1 ,2 ]
Samcova, Eva [1 ]
Stulik, Karel [2 ]
机构
[1] Charles Univ Prague, Inst Biochem Cell & Mol Biol, Fac Med 3, Prague 10000 10, Czech Republic
[2] Charles Univ Prague, Dept Analyt Chem, CR-11636 Prague 1, Czech Republic
关键词
Amino acids; Clinical samples; Contactless conductivity detection; Short pathway separation; LASER-INDUCED FLUORESCENCE; ZONE-ELECTROPHORESIS; HUMAN PLASMA; SEPARATION; CE; OPTIMIZATION; DIAGNOSIS;
D O I
10.1002/jssc.201000137
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
CE with contactless conductivity detection has been used to separate 28 biogenic amino acids in a short capillary with an effective length of 18 cm. All the tested amino acids can be mutually separated in 0.5-10 mol/L acetic acid electrolytes. The time of analysis does not exceed 6 min and the LODs vary from 0.1 to 1.7 mu mol/L. The CVs lie within the intervals 0.01-0.4% and 0.9-4% for the migration times and the analyte peak areas, respectively. The procedure has been successfully applied to the determinations of the whole amino acid spectra in blood plasma, urine, saliva and cerebrospinal fluid samples.
引用
收藏
页码:2394 / 2401
页数:8
相关论文
共 30 条
[1]   Determination of biochemical species on electrophoresis chips with an external contactless conductivity detector [J].
Abad-Villar, EM ;
Kubán, P ;
Hauser, PC .
ELECTROPHORESIS, 2005, 26 (19) :3609-3614
[2]   Heart-cutting 2-D CE using multiple detection points for chiral analysis of native amino acids [J].
Anouti, Suzanne ;
Vandenabeele-Trambouze, Odile ;
Koval, Dusan ;
Cottet, Herve .
ELECTROPHORESIS, 2009, 30 (01) :2-10
[3]   Separation of free amino acids in human plasma by capillary electrophoresis with laser induced fluorescence: potential for emergency diagnosis of inborn errors of metabolism [J].
Boulat, O ;
McLaren, DG ;
Arriaga, EA ;
Chen, DDY .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 754 (01) :217-228
[4]   Separation of twenty underivatized essential amino acids by capillary zone electrophoresis with contactless conductivity detection [J].
Coufal, P ;
Zuska, J ;
van de Goor, T ;
Smith, V ;
Gas, B .
ELECTROPHORESIS, 2003, 24 (04) :671-677
[5]  
DEVLIN TM, 1992, BIOCH CLIN CORRELATI
[6]   VALIDATION OF THE DETERMINATION OF AMINO-ACIDS IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING AUTOMATED PRECOLUMN DERIVATIZATION WITH O-PHTHALDIALDEHYDE [J].
FEKKES, D ;
VANDALEN, A ;
EDELMAN, M ;
VOSKUILEN, A .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 669 (02) :177-186
[7]  
Gas B, 2002, ELECTROPHORESIS, V23, P3520, DOI 10.1002/1522-2683(200210)23:20<3520::AID-ELPS3520>3.0.CO
[8]  
2-G
[9]   A review of the recent achievements in capacitively coupled contactless conductivity detection [J].
Kuban, Pavel ;
Hauser, Peter C. .
ANALYTICA CHIMICA ACTA, 2008, 607 (01) :15-29
[10]   Ten years of axial capacitively coupled contactless conductivity detection for CZE - a review [J].
Kuban, Pavel ;
Hauser, Peter C. .
ELECTROPHORESIS, 2009, 30 (01) :176-188