Rapid ventricular pacing in a pacemaker patient undergoing magnetic resonance imaging

被引:70
作者
Fontaine, JM [1 ]
Mohamed, FB [1 ]
Gottlieb, C [1 ]
Callans, DJ [1 ]
Marchlinski, FE [1 ]
机构
[1] Allegheny Univ Hlth Sci Hosp, Med Coll Penn & Hahnemann Univ, Sch Med, MCP Div, Philadelphia, PA 19129 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1998年 / 21卷 / 06期
关键词
magnetic resonance imaging; pacemaker; arrhythmia;
D O I
10.1111/j.1540-8159.1998.tb00202.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Magnetic resonance imaging (MRI) generates potent electromagnetic forces in the form of a static, gradient, or pulsed radiofrequency magnetic field that can result in pacemaker malfunction. This report documents a case of rapid cardiac pacing during MRI in a patient with a dual chamber pacemaker. Although the mechanism of rapid cardiac pacing is unclear, it was directly related to radiofrequency pulsing. We postulated that the lead acts as an antenna for radiofrequency energy that interacts with the pacemaker's output circuit, thus, causing cardiac pacing at a cycle length representing a multiple of the repetition time; or perhaps rapid pacing is related to induced currents generated between the MRI unit and the pacing lead.
引用
收藏
页码:1336 / 1339
页数:4
相关论文
共 12 条
[1]   NUCLEAR MAGNETIC-RESONANCE IMAGING IN A PATIENT WITH A DDD PACEMAKER [J].
ALAGONA, P ;
TOOLE, JC ;
MANISCALCO, BS ;
GLOVER, MU ;
ABERNATHY, GT ;
PRIDA, XE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (04) :619-619
[2]  
AVERY JE, 1988, J TENNESSEE MED ASS, V81, P53
[3]   EFFECT OF MAGNETIC-RESONANCE-IMAGING ON DDD PACEMAKERS [J].
ERLEBACHER, JA ;
CAHILL, PT ;
PANNIZZO, F ;
KNOWLES, RJR .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (06) :437-440
[4]   THE EFFECTS OF NUCLEAR MAGNETIC-RESONANCE IMAGERS ON EXTERNAL AND IMPLANTABLE PULSE GENERATORS [J].
FETTER, J ;
ARAM, G ;
HOLMES, DR ;
GRAY, JE ;
HAYES, DL .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (04) :720-727
[5]   Safe performance of magnetic resonance imaging on five patients with permanent cardiac pacemakers [J].
Gimbel, JR ;
Johnson, D ;
Levine, PA ;
Wilkoff, BL .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (06) :913-919
[6]   PACEMAKER MALFUNCTION [J].
HAYES, DL ;
VLIETSTRA, RE .
ANNALS OF INTERNAL MEDICINE, 1993, 119 (08) :828-835
[7]   EFFECT OF 1.5 TESLA NUCLEAR-MAGNETIC-RESONANCE IMAGING SCANNER ON IMPLANTED PERMANENT PACEMAKERS [J].
HAYES, DL ;
HOLMES, DR ;
GRAY, JE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (04) :782-786
[8]   THE EFFECTS OF NUCLEAR MAGNETIC-RESONANCE ON PATIENTS WITH CARDIAC-PACEMAKERS [J].
PAVLICEK, W ;
GEISINGER, M ;
CASTLE, L ;
BORKOWSKI, GP ;
MEANEY, TF ;
BREAM, BL ;
GALLAGHER, JH .
RADIOLOGY, 1983, 147 (01) :149-153
[9]   INDUCTION OF MICROCURRENTS IN CRITICALLY ILL PATIENTS IN MAGNETIC-RESONANCE SYSTEMS [J].
PEDEN, CJ ;
COLLINS, AG ;
BUTSON, PC ;
WHITWAM, JG ;
YOUNG, IR .
CRITICAL CARE MEDICINE, 1993, 21 (12) :1923-1928
[10]   SAFETY OF PATIENTS WITH MEDICAL DEVICES DURING APPLICATION OF MAGNETIC-RESONANCE METHODS [J].
POHOST, GM ;
BLACKWELL, GG ;
SHELLOCK, FG .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES-SERIES, 1992, 649 :302-312