An optical fiber biosensor for choline-containing phospholipids monitoring in serum samples is described. Phospholipids are hydrolyzed by the enzyme phospholipase-D to choline which is analyzed with a fiber-optic biosensor based on choline oxidase and oxygen transduction. Several supports have been evaluated for enzyme immobilization. The optimum biosensing layer consists of the enzyme immobilized on a nylon membrane and placed onto an oxygen sensitive layer formed by a luminescent Ru(II) complex, tris(4,-diphenyl-1,10-phenanthroline)ruthenium(II), dispersed in a silicone membrane. The performance of the biosensor has been optimized using a flow injection system. The linear dynamic range of the biosensing membranes is found to be 0.08-3.00 mg ml(-1) phosphatidylcholine. Studies of the reproducibility, stability and interferences of the device, as well as the application of the sensor to measurements in serum samples, are reported. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:19 / 29
页数:11
相关论文
共 31 条
[1]  
ANAOKAR S, 1979, CLIN CHEM, V25, P103
[2]   ENZYME SENSOR FOR THE DETERMINATION OF CHOLINE-CONTAINING PHOSPHOLIPIDS IN SOME BIOLOGICAL-FLUIDS [J].
CAMPANELLA, L ;
TOMASSETTI, M ;
SAMMARTINO, MP .
ANALYST, 1988, 113 (01) :77-80
[3]  
EXTON JH, 1990, J BIOL CHEM, V265, P1
[4]  
Fennema O. R., 1993, QUIMICA ALIMENTOS
[5]   DIAGNOSIS OF RESPIRATORY DISTRESS SYNDROME BY AMNIOCENTESIS [J].
GLUCK, L ;
KULOVICH, MV ;
BORER, RC ;
BRENNER, PH ;
ANDERSON, GG ;
SPELLACY, WN .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1971, 109 (03) :440-&
[6]   A WATER-INSOLUBLE POLYANIONIC DERIVATIVE OF TRYPSIN .2. EFFECT OF POLYELECTROLYTE CARRIER ON KINETIC BEHAVIOR OF BOUND TRYPSIN [J].
GOLDSTEIN, L ;
LEVIN, Y ;
KATCHALSKI, E .
BIOCHEMISTRY, 1964, 3 (12) :1913-+
[7]   AMPEROMETRIC SENSOR FOR CHOLINE AND ACETYLCHOLINE BASED ON A PLATINUM-ELECTRODE MODIFIED BY A CO-CROSS-LINKED BIENZYMIC SYSTEM [J].
GUERRIERI, A ;
DEBENEDETTO, GE ;
PALMISANO, F ;
ZAMBONIN, PG .
ANALYST, 1995, 120 (11) :2731-2736
[8]  
GURANTZ D, 1981, J LIPID RES, V22, P373
[9]   DIFFERENTIAL PULSE POLAROGRAPHIC-DETERMINATION OF SOME CARCINOGENIC NITROSAMINES [J].
HASEBE, K ;
OSTERYOUNG, J .
ANALYTICAL CHEMISTRY, 1975, 47 (14) :2412-2418
[10]  
HORNBY WE, 1975, IMMOBILIZED ENZYMES