Determination of ytterbium in animal faeces by tungsten coil electrothermal atomic absorption spectrometry

被引:56
作者
Lima, EC [1 ]
Krug, FJ [1 ]
Nobrega, JA [1 ]
Nogueira, ARA [1 ]
机构
[1] Univ Sao Paulo, Ctr Energia Nucl Agr, BR-13400970 Piracicaba, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
ytterbium; animal faeces; tungsten coil atomizer; electrothermal atomic absorption spectrometry;
D O I
10.1016/S0039-9140(98)00087-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for ytterbium determination in animal faeces by tungsten coil electrothermal atomic absorption spectrometry (TCAAS) was developed. Faeces were dry-ashed in a muffle furnace, the ashes were treated with hydrochloric acid, and 10 mu l of sample solution were delivered into 150-W tungsten coil atomizer. A matrix-matching procedure employing a 66-s heating program proved to be efficient for obtaining accurate results. Characteristic mass and detection limit were 7.1 pg and 0.35 mu g g(-1) Yb, respectively. The tungsten coil atomizer lifetime exceeded 300 firings with digested solutions and R.S.D. of measurements was 1.9% after ten consecutive injections of 10.0 mu g l(-1) Yb. Accuracy of the proposed method was assessed by employing a graphite furnace atomic absorption spectrometric procedure. Application of the paired t-test did not reveal any significant difference for ytterbium contents determined by both methods at 95% confidence level, it was demonstrated that the proposed procedure can successfully be used for evaluation of kinetic passage rate of feed through digestive tract of animals. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:613 / 623
页数:11
相关论文
共 32 条
[1]   SIMPLE LOW-COST TUNGSTEN-COIL ATOMIZER FOR ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BERNDT, H ;
SCHALDACH, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (05) :709-712
[2]   ANALYTICAL EVALUATION OF A TUNGSTEN COIL ATOMIZER FOR CADMIUM, LEAD, CHROMIUM, MANGANESE, NICKEL AND COBALT DETERMINATION BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BRUHN, CG ;
AMBIADO, FE ;
CID, HJ ;
WOERNER, R ;
TAPIA, J ;
GARCIA, R .
ANALYTICA CHIMICA ACTA, 1995, 306 (2-3) :183-192
[3]  
Bruhn CG, 1996, QUIM ANAL, V15, P191
[4]   COMPARISON OF SODIUM-CHLORIDE AND MAGNESIUM-CHLORIDE INTERFERENCES IN CONTINUUM SOURCE ATOMIC-ABSORPTION SPECTROMETRY WITH WALL, PLATFORM AND PROBE ELECTROTHERMAL ATOMIZATION [J].
CARROLL, J ;
MILLERIHLI, NJ ;
HARNLY, JM ;
OHAVER, TC ;
LITTLEJOHN, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (03) :533-538
[5]   DETERMINATION OF BERYLLIUM IN DRINKING AND WASTE-WATER BY TUNGSTEN FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
CERNOHORSKY, T ;
KOTRLY, S .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (02) :155-160
[6]  
*COMM SPECTR OTH O, 1978, SPECTROCHIM ACTA B, V33, P241
[7]   DETERMINATION OF CADMIUM IN BIOLOGICAL-MATERIALS BY TUNGSTEN COIL ATOMIC-ABSORPTION SPECTROMETRY [J].
GINE, MF ;
KRUG, FJ ;
SASS, VA ;
REIS, BF ;
NOBREGA, JA ;
BERNDT, H .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (02) :243-245
[8]  
Greenwood N. N., 1984, CHEM ELEMENTS, P1542
[9]  
Knochen M, 1996, QUIM ANAL, V15, P184