Initial results and 6 month clinical follow-up after implantation of a silicon carbide coated coronary stent

被引:10
作者
Fournier, JA
Calabuig, J
Merchán, A
Augé, JM
Melgares, R
Colman, T
de Dios, RM
Insa, L
Santos, I
机构
[1] Hosp Univ Virgen Rocio, Seville, Spain
[2] Univ Navarra Clin, Pamplona, Spain
[3] Hosp Infanta Cristina, Badajoz, Spain
[4] Hosp Santa Creu & Sant Pau, E-08025 Barcelona, Spain
[5] Hosp Univ Virgen Nieves, Granada, Spain
[6] Hosp Marques Valdecilla, Santander, Spain
[7] Clin Ruber Int, Madrid, Spain
[8] Hosp Clin Univ, Valencia, Spain
[9] Hosp Clin Univ, Salamanca, Spain
来源
REVISTA ESPANOLA DE CARDIOLOGIA | 2001年 / 54卷 / 05期
关键词
coronary angioplasty; registries; stent;
D O I
10.1016/S0300-8932(01)76358-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and objectives. To present the initial Spanish experience with the Tenax coronary stent, a laser sculpted from high-precision 316L stainless steel coated with hydrogen rich amorphous silicon carbide that reduces thrombogenecity and improves biocompatibility. Patients and methods. From July 1998 to July 1999, 206 patients (62 +/- 5 years) underwent implantation of 231 Tenax stents in 9 centers as the only revascularization procedure. The most frequent clinical indication was unstable angina (66%), and most of the lesions were complex (class B2 and C). The target vessels were the left anterior descending (51%) and right coronary arteries (36%). The ejection fraction was < 0.5 in 19% cases. Results. Revascularization was complete in 70%, elective in 80%, and the implantation was direct in 25% of the cases. The procedure was successful in all the lesions, reducing stenosis from 62 +/- 16 to 16 +/- 10% and increasing the minimal luminal diameter from 0.81 +/- 0.40 to 2.61 +/- 0.59 mm. The TIMI flow was reduced in 30%, but normalized after the stent in all but one case: The incidence of cardiac events was minimal: 1 acute thrombosis (0.5%) resolved by a new angioplasty and 1 non-Q myocardial infarction (0.5%). At the 6-month clinical follow-up 10% of the patients presented complaints of angina greater than class II, and a new angioplasty was carried out in 1.9% of these cases. Conclusion. Clinical and angiographic data suggest that the hydrogenated silicon cart,ide coating of the Tenax coronary stent may indeed play a beneficial role in patient outcome, and should therefore be evaluated by prospective clinical trials.
引用
收藏
页码:567 / 572
页数:6
相关论文
共 26 条
[1]  
ALMAGOR Y, 1997, J AM COLL CARDIOL, V133, P369
[2]   HEMOCOMPATIBILITY OPTIMIZATION OF IMPLANTS BY HYBRID STRUCTURING [J].
BOLZ, A ;
SCHALDACH, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 :S123-S130
[3]  
Bolz A, 1996, TEX HEART I J, V23, P162
[4]  
Bolz A., 1991, ARTIF ORGANS, V14, P151
[5]  
CARRIE D, 1999, PROG BIOMED RES, V4, P99
[6]   INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE [J].
COLOMBO, A ;
HALL, P ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
MARTINI, G ;
GAGLIONE, A ;
GOLDBERG, SL ;
TOBIS, JM .
CIRCULATION, 1995, 91 (06) :1676-1688
[7]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[8]   Direct coronary stenting without balloon predilation in acute coronary syndromes [J].
Hamon, M ;
Richardeau, Y ;
Lécluse, E ;
Saloux, E ;
Sabatier, R ;
Agostini, D ;
Filmont, JE ;
Grollier, G ;
Potier, JC .
AMERICAN HEART JOURNAL, 1999, 138 (01) :55-59
[9]  
HANEKAMP C, 1999, PROG BIOMED RES, V4, P90
[10]  
HANEKAMP CE, 1999, PROG BIOMED RES, V4, P96