Initial results and 6 month clinical follow-up after implantation of a silicon carbide coated coronary stent

被引:10
作者
Fournier, JA
Calabuig, J
Merchán, A
Augé, JM
Melgares, R
Colman, T
de Dios, RM
Insa, L
Santos, I
机构
[1] Hosp Univ Virgen Rocio, Seville, Spain
[2] Univ Navarra Clin, Pamplona, Spain
[3] Hosp Infanta Cristina, Badajoz, Spain
[4] Hosp Santa Creu & Sant Pau, E-08025 Barcelona, Spain
[5] Hosp Univ Virgen Nieves, Granada, Spain
[6] Hosp Marques Valdecilla, Santander, Spain
[7] Clin Ruber Int, Madrid, Spain
[8] Hosp Clin Univ, Valencia, Spain
[9] Hosp Clin Univ, Salamanca, Spain
来源
REVISTA ESPANOLA DE CARDIOLOGIA | 2001年 / 54卷 / 05期
关键词
coronary angioplasty; registries; stent;
D O I
10.1016/S0300-8932(01)76358-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and objectives. To present the initial Spanish experience with the Tenax coronary stent, a laser sculpted from high-precision 316L stainless steel coated with hydrogen rich amorphous silicon carbide that reduces thrombogenecity and improves biocompatibility. Patients and methods. From July 1998 to July 1999, 206 patients (62 +/- 5 years) underwent implantation of 231 Tenax stents in 9 centers as the only revascularization procedure. The most frequent clinical indication was unstable angina (66%), and most of the lesions were complex (class B2 and C). The target vessels were the left anterior descending (51%) and right coronary arteries (36%). The ejection fraction was < 0.5 in 19% cases. Results. Revascularization was complete in 70%, elective in 80%, and the implantation was direct in 25% of the cases. The procedure was successful in all the lesions, reducing stenosis from 62 +/- 16 to 16 +/- 10% and increasing the minimal luminal diameter from 0.81 +/- 0.40 to 2.61 +/- 0.59 mm. The TIMI flow was reduced in 30%, but normalized after the stent in all but one case: The incidence of cardiac events was minimal: 1 acute thrombosis (0.5%) resolved by a new angioplasty and 1 non-Q myocardial infarction (0.5%). At the 6-month clinical follow-up 10% of the patients presented complaints of angina greater than class II, and a new angioplasty was carried out in 1.9% of these cases. Conclusion. Clinical and angiographic data suggest that the hydrogenated silicon cart,ide coating of the Tenax coronary stent may indeed play a beneficial role in patient outcome, and should therefore be evaluated by prospective clinical trials.
引用
收藏
页码:567 / 572
页数:6
相关论文
共 26 条
[21]   A COMPARISON OF BALLOON-EXPANDABLE-STENT IMPLANTATION WITH BALLOON ANGIOPLASTY IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
SERRUYS, PW ;
DEJAEGERE, P ;
KIEMENEIJ, F ;
MACAYA, C ;
RUTSCH, W ;
HEYNDRICKX, G ;
EMANUELSSON, H ;
MARCO, J ;
LEGRAND, V ;
MATERNE, P ;
BELARDI, J ;
SIGWART, U ;
COLOMBO, A ;
GOY, JJ ;
VANDENHEUVEL, P ;
DELCAN, J ;
MOREL, MA .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :489-495
[22]   INTRAVASCULAR STENTS TO PREVENT OCCLUSION AND RESTENOSIS AFTER TRANS-LUMINAL ANGIOPLASTY [J].
SIGWART, U ;
PUEL, J ;
MIRKOVITCH, V ;
JOFFRE, F ;
KAPPENBERGER, L .
NEW ENGLAND JOURNAL OF MEDICINE, 1987, 316 (12) :701-706
[23]  
Soriano J, 1999, REV ESP CARDIOL, V52, P1105
[24]  
Unverdorben M., 1996, European Heart Journal, V17, P178
[25]  
VANOEVEREN W, 1999, PROG BIOMED RES, V4, P78
[26]   Immediate and late outcomes after direct stent implantation without balloon predilation [J].
Wilson, SH ;
Berger, PB ;
Mathew, V ;
Bell, MR ;
Garratt, KN ;
Rihal, CS ;
Bresnahan, JF ;
Grill, DE ;
Melby, S ;
Holmes, DR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (04) :937-943