A new mathematical model for relative quantification in real-time RT-PCR

被引:29271
作者
Pfaffl, MW [1 ]
机构
[1] Tech Univ Munchen Weihenstephan, Inst Physiol, FML Weihenstephan, Ctr Life & Food Sci, D-85354 Freising Weihenstephan, Germany
关键词
D O I
10.1093/nar/29.9.e45
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Use of the real-time polymerase chain reaction (PCR) to amplify cDNA products reverse transcribed from mRNA is on the way to becoming a routine took in molecular biology to study low abundance gene expression. Real-time PCR is easy to perform, provides the necessary accuracy and produces reliable as well as rapid quantification results. But accurate quantification of nucleic acids requires a reproducible methodology and an adequate mathematical model for data analysis. This study enters into the particular topics of the relative quantification in real-time RT-PCR of a target gene transcript in comparison to a reference gene transcript. Therefore, a new mathematical model is presented. The relative expression ratio is calculated only from the real-time PCR efficiencies and the crossing point deviation of an unknown sample versus a control. This model needs no calibration curve. Control levels were included in the model to standardise each reaction run with respect to RNA integrity, sample loading and inter-PCR variations. High accuracy and reproducibility (<2.5% variation) were reached in LightCycler PCR using the established mathematical model.
引用
收藏
页数:6
相关论文
共 25 条
[1]
[Anonymous], 2001, Rapid Cycle Real-Time PCR
[2]
STIMULATION OF GLYCERALDEHYDE-3-PHOSPHATE DEHYDROGENASE MESSENGER-RNA LEVELS BY ENDOGENOUS NITRIC-OXIDE IN CYTOKINE-ACTIVATED ENDOTHELIUM [J].
BERETA, J ;
BERETA, M .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1995, 217 (01) :363-369
[3]
COMPARISON OF GLYCERALDEHYDE-3-PHOSPHATE DEHYDROGENASE AND 28S-RIBOSOMAL RNA GENE-EXPRESSION AS RNA LOADING CONTROLS FOR NORTHERN BLOT ANALYSIS OF CELL-LINES OF VARYING MALIGNANT POTENTIAL [J].
BHATIA, P ;
TAYLOR, WR ;
GREENBERG, AH ;
WRIGHT, JA .
ANALYTICAL BIOCHEMISTRY, 1994, 216 (01) :223-226
[4]
Absolute quantification of mRNA using real-time reverse transcription polymerase chain reaction assays [J].
Bustin, SA .
JOURNAL OF MOLECULAR ENDOCRINOLOGY, 2000, 25 (02) :169-193
[5]
Chang TJ, 1998, ONCOL REP, V5, P469
[6]
Ferre F, 1992, PCR Methods Appl, V2, P1
[7]
Regulation of hypoxanthine phosphoribosyltransferase, glyceraldehyde-3-phosphate dehydrogenase and β-actin mRNA expression in porcine immune cells and tissues [J].
Foss, DL ;
Baarsch, MJ ;
Murtaugh, MP .
ANIMAL BIOTECHNOLOGY, 1998, 9 (01) :67-78
[8]
Quantitative RT-PCR: Pitfalls and potential [J].
Freeman, WM ;
Walker, SJ ;
Vrana, KE .
BIOTECHNIQUES, 1999, 26 (01) :112-+
[9]
A novel method for real time quantitative RT PCR [J].
Gibson, UEM ;
Heid, CA ;
Williams, PM .
GENOME RESEARCH, 1996, 6 (10) :995-1001
[10]
KINETIC PCR ANALYSIS - REAL-TIME MONITORING OF DNA AMPLIFICATION REACTIONS [J].
HIGUCHI, R ;
FOCKLER, C ;
DOLLINGER, G ;
WATSON, R .
BIO-TECHNOLOGY, 1993, 11 (09) :1026-1030