Time of flight in PET revisited

被引:277
作者
Moses, WW [1 ]
机构
[1] Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
基金
美国国家卫生研究院;
关键词
nuclear medicine; positron emission tomography (PET); time of flight; timing resolution;
D O I
10.1109/TNS.2003.817319
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
PET scanners based on LSO have the potential for significantly better coincidence timing resolution than the 6 ns FWHM typically achieved with BGO. This study analyzes the performance enhancements made possible by improved timing as a function of the coincidence time resolution. If 500 ps FWHM coincidence timing. resolution can be achieved in a complete PET camera, the following four benefits can be realized for whole-body FDG imaging: 1) the random event rate can be reduced by using a narrower coincidence timing window, increasing the peak NECR by similar to50%; 2) using time-of-flight (TOF) in the reconstruction algorithm will reduce the noise variance by a factor of 5; 3) emission and transmission data can be acquired simultaneously, reducing the total scan time; and 4) axial blurring can be reduced by using TOF to determine the correct axial plane of origin for each event. While TOF was extensively studied in the 1980s, practical factors limited its effectiveness at that time and little attention has been paid to timing in PET since then. As these potential improvements are substantial and the advent of LSO PET cameras gives us the means to obtain them without other sacrifices, efforts to improve PET timing should resume after their long dormancy.
引用
收藏
页码:1325 / 1330
页数:6
相关论文
共 34 条
[1]  
ANGER HO, 1966, ISA T, V5, P311
[2]   A TECHNIQUE FOR THE CORRECTION OF SCATTERED RADIATION IN A PET SYSTEM USING TIME-OF-FLIGHT INFORMATION [J].
BENDRIEM, B ;
SOUSSALINE, F ;
CAMPAGNOLO, R ;
VERREY, B ;
WAJNBERG, P ;
SYROTA, A .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (02) :287-295
[3]  
CAMPAGNOLO RE, 1979, COMM C NAT TRAIT SIG
[4]   A MULTICRYSTAL 2-DIMENSIONAL BGO DETECTOR SYSTEM FOR POSITRON EMISSION TOMOGRAPHY [J].
CASEY, ME ;
NUTT, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :460-463
[5]  
DAUBEWITHERSPOON ME, 1987, J NUCL MED, V28, P1717
[6]   Exact and approximate rebinning algorithms for 3-D PET data [J].
Defrise, M ;
Kinahan, PE ;
Townsend, DW ;
Michel, C ;
Sibomana, M ;
Newport, DF .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) :145-158
[7]  
Holmes T J, 1984, IEEE Trans Med Imaging, V3, P68, DOI 10.1109/TMI.1984.4307659
[8]   MODELING OF ACCIDENTAL COINCIDENCES IN BOTH CONVENTIONAL AND TIME-OF-FLIGHT POSITRON-EMISSION TOMOGRAPHY [J].
HOLMES, TJ ;
FICKE, DC ;
SNYDER, DL .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) :627-631
[9]   CONSTRUCTION FUNCTION FOR 3-DIMENSIONAL SINOGRAMS OF THE TIME-OF-FLIGHT POSITRON EMISSION TOMOGRAPH [J].
ISHII, K ;
ORIHARA, H ;
MATSUZAWA, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1987, 58 (09) :1699-1701
[10]   LUALO3-CE AND OTHER ALUMINATE SCINTILLATORS [J].
LEMPICKI, A ;
RANDLES, MH ;
WISNIEWSKI, D ;
BALCERZYK, M ;
BRECHER, C ;
WOJTOWICZ, AJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :280-284