Evaluation of corollary artery stenoses using electron-beam CT and multiplanar reformation

被引:62
作者
Nakanishi, T [1 ]
Ito, K [1 ]
Imazu, M [1 ]
Yamakido, M [1 ]
机构
[1] HIROSHIMA UNIV,SCH MED,DEPT INTERNAL MED 2,MINAMI KU,HIROSHIMA 734,JAPAN
关键词
arteries; coronary; stenosis; computed tomography; techniques;
D O I
10.1097/00004728-199701000-00024
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We assessed the diagnostic value of electron-beam CT with multiplanar reformation for coronary artery stenoses. Method: Thirty-seven patients who underwent conventional coronary angiography were evaluated with EGG-triggered thin section electron-beam CT with intravenous contrast enhancement. Multiplanar reformation of a stack of the images was performed to visualize coronary arteries. Two observers blind to the results of conventional coronary angiography independently evaluated the reformatted images. Results: The sensitivity and specificity for the detection of significant lesions were 100 and 100% in the left main coronary artery, 83 and 84% in the left anterior descending artery, 67 and 96% in left circumflex artery, 63 and 79% in the right coronary artery, and 74 and 94% for total results, respectively. All false-positive results in the left anterior descending artery were caused by wall calcification, and in the right coronary artery, 83% of the false-positive results were caused by small slice gaps in noncalcified segments. Conclusion: Electron-beam CT was feasible for the detection of coronary artery stenoses. For interpretation of reformatted images, calcification and slice gaps should be taken into consideration.
引用
收藏
页码:121 / 127
页数:7
相关论文
共 23 条
[11]   VALUE OF ULTRAFAST CT SCANNING IN CARDIOLOGY [J].
LIPTON, MJ ;
HOLT, WW .
BRITISH MEDICAL BULLETIN, 1989, 45 (04) :991-&
[12]   A PRELIMINARY-REPORT COMPARING MAGNETIC-RESONANCE CORONARY ANGIOGRAPHY WITH CONVENTIONAL ANGIOGRAPHY [J].
MANNING, WJ ;
LI, W ;
EDELMAN, RR .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 328 (12) :828-832
[13]   FAT-SUPPRESSED BREATH-HOLD MAGNETIC-RESONANCE CORONARY ANGIOGRAPHY [J].
MANNING, WJ ;
LI, W ;
BOYLE, NG ;
EDELMAN, RR .
CIRCULATION, 1993, 87 (01) :94-104
[14]   DIAGNOSIS OF CAROTID-ARTERY DISEASE - PRELIMINARY EXPERIENCE WITH MAXIMUM-INTENSITY-PROJECTION SPIRAL CT ANGIOGRAPHY [J].
MARKS, MP ;
NAPEL, S ;
JORDAN, JE ;
ENZMANN, DR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (06) :1267-1271
[15]   CORONARY-ARTERY STENOSES - 3-DIMENSIONAL IMAGING WITH ELECTROCARDIOGRAPHICALLY TRIGGERED, CONTRAST AGENT-ENHANCED, ELECTRON-BEAM CT [J].
MOSHAGE, WEL ;
ACHENBACH, S ;
SEESE, B ;
BACHMANN, K ;
KIRCHGEORG, M .
RADIOLOGY, 1995, 196 (03) :707-714
[16]  
RICH S, 1996, MARCUS CARDIAC IMAGI, P829
[17]   3-DIMENSIONAL SPIRAL CT ANGIOGRAPHY OF THE ABDOMEN - INITIAL CLINICAL-EXPERIENCE [J].
RUBIN, GD ;
DAKE, MD ;
NAPEL, SA ;
MCDONNELL, CH ;
JEFFREY, RB .
RADIOLOGY, 1993, 186 (01) :147-152
[18]   SPIRAL CT OF RENAL-ARTERY STENOSIS - COMPARISON OF 3-DIMENSIONAL RENDERING TECHNIQUES [J].
RUBIN, GD ;
DAKE, MD ;
NAPEL, S ;
JEFFREY, RB ;
MCDONNELL, CH ;
SOMMER, FG ;
WEXLER, L ;
WILLIAMS, DM .
RADIOLOGY, 1994, 190 (01) :181-189
[19]   QUANTITATIVE DYNAMICS OF LEFT-VENTRICULAR EMPTYING AND FILLING AS A FUNCTION OF HEART SIZE AND STROKE VOLUME IN PURE AORTIC REGURGITATION AND IN NORMAL SUBJECTS [J].
RUMBERGER, JA ;
REED, JE .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (11) :1045-1050
[20]   EVALUATION OF CEREBRAL ANEURYSMS WITH HELICAL CT - CORRELATION WITH CONVENTIONAL ANGIOGRAPHY AND MR-ANGIOGRAPHY [J].
SCHWARTZ, RB ;
TICE, HM ;
HOOTEN, SM ;
HSU, LG ;
STIEG, PE .
RADIOLOGY, 1994, 192 (03) :717-722