Application of Doehlert designs for optimisation of an on-line preconcentration system for copper determination by flame atomic absorption spectrometry

被引:73
作者
Ferreira, SLC
Bezerra, MA
dos Santos, WNL
Neto, BB
机构
[1] Univ Fed Bahia, Inst Quim, Grp Pesquisa Quim Analit, BR-40170290 Salvador, BA, Brazil
[2] Univ Estadual Sudoeste Bahia, Dept Quim & Exatas, BR-45200190 Jequie, BA, Brazil
[3] Univ Fed Pernambuco, Inst Quim, Recife, PE, Brazil
关键词
Doehlert designs; copper; flame atomic absorption spectrometry;
D O I
10.1016/S0039-9140(03)00277-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present paper, a system for on-line preconcentration and determination of copper by flame atomic absorption spectrometry (FAAS) was developed. It was based on solid phase extraction of copper(II) ions on a minicolumn of Amberlite XAD-2 loaded with 2-(2-thiazolylazo)-5-dimethylaminophenoI (TAM). The optimisation process was carried out using Doehlert designs. Four variables (sampling flow rate, SR; elution flow rate, buffer concentration, BC; and pH) were regarded as factors in the optimisation. The parameter "sensitivity efficiency (SE)" proposed in this paper, and defined as the analytical signal obtained for an on-line enrichment system for a preconcentration time of 1 min was used as analytical response in the optimisation process. Using the established experimental conditions, the proposed on-line system allowed determination of copper with detection limit (3sigma/S) of 0.23 mug l(-1), and a precision (repeatability), calculated as relative standard deviation (R.S.D.) of 3.9 and 3.7% for copper concentration of 5.00 and 20.00 mug l(-1), respectively. The preconcentration factor obtained is 62. The recovery achieved for copper determination in presence of several cations demonstrated that this has enough selectivity for analysis of food samples. The robustness of the proposed system was also evaluated. The accuracy was confirmed by analysis of the following certified reference materials (CRMs): Rice flour NIES 10a, Spinach leaves NIST 1570a, Apples leaves NIST 1515 and Orchard leaves NBS 1571. This procedure was applied for copper determination in natural food samples. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:295 / 303
页数:9
相关论文
共 28 条
[1]   Experimental design .2. Optimization [J].
Araujo, PW ;
Brereton, RG .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (02) :63-70
[2]   Optimization of a microwave-pseudo-digestion procedure by experimental designs for the determination of trace elements in seafood products by atomic absorption spectrometry [J].
Bermejo-Barrera, P ;
Moreda-Piñeiro, A ;
Muñiz-Naveiro, O ;
Gómez-Fernández, AMJ ;
Bermejo-Barrera, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (08) :1351-1371
[3]  
Box G. E. P., 1997, STAT EXPT
[4]   Experimental design methodologies to optimise the spectrofluorimetric determination of Losartan and Valsartan in human urine [J].
Cagigal, E ;
González, L ;
Alonso, RM ;
Jiménez, RM .
TALANTA, 2001, 54 (06) :1121-1133
[5]   Multivariate optimization of solvent extraction of Cd(II), Co(II), Cr(VI), Cu(II), Ni(II), Pb(II) and Zn(II) as dibenzyldithiocarbamates and detection by AAS [J].
Camino, M ;
Bagur, MG ;
Sánchez-Viñas, M ;
Gázquez, D ;
Romero, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (06) :638-642
[6]  
CUADROSRODRIGUE.L, 1998, CHEMOM INTELL LAB SY, V41, P57
[7]   Optimisation of the extraction of arsenic species from mussels with low power focused microwaves by applying a Doehlert design [J].
Dagnac, T ;
Padró, A ;
Rubio, R ;
Rauret, G .
ANALYTICA CHIMICA ACTA, 1998, 364 (1-3) :19-30
[8]  
Doehlert D.H., 1970, Appl. Stat, V19, P231
[9]   Determination of cadmium in mussels by flame atomic absorption spectrometry with preconcentration on a chelating resin in a flow injection system [J].
Enríquez-Domínguez, MF ;
Yebra-Biurrun, MC ;
Bermejo-Barrera, MP .
ANALYST, 1998, 123 (01) :105-108
[10]  
Fang Z., 1993, FLOW INJECTION SEPAR