Experimental comparison of three monoclonal antibodies for the class-selective immunoextraction of triazines - Correlation with molecular modeling and principal component analysis studies

被引:53
作者
Delaunay-Bertoncini, N [1 ]
Pichon, V [1 ]
Hennion, MC [1 ]
机构
[1] Ecole Super Phys & Chim Ind Ville Paris, Lab Environm & Chim Analyt, F-75231 Paris 05, France
关键词
molecular modeling; principal component analysis; affinity sorbents; solid-phase extraction; immunoextraction; monoclonal antibodies; triazines;
D O I
10.1016/S0021-9673(03)00425-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The specificity of three immunosorbents (ISs) based on different monoclonal anti-triazine antibodies has been characterized by extraction recoveries studies and with step elution experiments. Both indicated that the anti-dichloroatrazine IS is specific of terbutylazine and cyanazine. The anti-atrazine IS is specific of the chlorotriazines, whereas the anti-ametryn IS can trap all the triazines. This confirms the great influence of the hapten design on the specificity of the resulting antibodies, even if the target molecules are small. Moreover, the anti-ametryn IS is suitable for class-selective extraction of triazines contained in complex matrices. An approach designed to learn more about the specificity for a group of structurally related compounds of antibodies produced with a given compound is proposed and evaluated. Molecular modeling followed by principal component analysis has been used to obtain distribution maps with the relative position of each immunoconjugate and all the triazines. In all three cases, conclusions on specificity made with the analysis of the maps fit well with the experimental results. Consequently, molecular modeling coupled with principal component analysis seems to be a unique, inexpensive, and rapid tool to select the appropriate hapten providing highly specific or class-specific antibodies according to the given problem. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:3 / 15
页数:13
相关论文
共 29 条
[1]   Influence of the hapten design on the development of a competitive ELISA for the determination of the antifouling agent Irgarol 1051 at trace levels [J].
Ballesteros, B ;
Barceló, D ;
Sanchez-Baeza, F ;
Camps, F ;
Marco, MP .
ANALYTICAL CHEMISTRY, 1998, 70 (19) :4004-4014
[2]   Detection of polycyclic aromatic hydrocarbon metabolites by high-pressure liquid chromatography after purification on immunoaffinity columns in urine from occupationally exposed workers [J].
Bentsen-Farmen, RK ;
Botnen, IV ;
Noto, H ;
Jacob, J ;
Ovrebo, S .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1999, 72 (03) :161-168
[3]   On-line coupling of immunosorbent and liquid chromatographic analysis for the selective extraction and determination of polycyclic aromatic hydrocarbons in water samples at the ng 1-1 level [J].
Bouzige, M ;
Pichon, V ;
Hennion, MC .
JOURNAL OF CHROMATOGRAPHY A, 1998, 823 (1-2) :197-210
[4]   Characterization of monoclonal antibodies raised against different structures belonging to the s-triazine group of herbicides [J].
Bruun, L ;
Koch, C ;
Jakobsen, MH ;
Pedersen, B ;
Christiansen, M ;
Aamand, J .
ANALYTICA CHIMICA ACTA, 2001, 436 (01) :87-101
[5]   On-line coupling of immunoaffinity-based solid-phase extraction and gas chromatography for the determination of s-triazines in aqueous samples [J].
Dallüge, J ;
Hankemeier, T ;
Vreuls, RJJ ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1999, 830 (02) :377-386
[6]   Immunoaffinity solid-phase extraction for the trace-analysis of low-molecular-mass analytes in complex sample matrices [J].
Delaunay, N ;
Pichon, V ;
Hennion, MC .
JOURNAL OF CHROMATOGRAPHY B, 2000, 745 (01) :15-37
[7]   Comparison of immunoextraction sorbents prepared from monoclonal and polyclonal anti-isoproturon antibodies and optimization of the appropriate monoclonal antibody-based sorbent for environmental and biological applications [J].
Delaunay-Bertoncini, N ;
Pichon, V ;
Hennion, MC .
CHROMATOGRAPHIA, 2001, 53 (Suppl 1) :S224-S230
[8]   Immunosorbents coupled on line with liquid chromatography atmospheric pressure chemical ionization mass spectrometry for the part per trillion level determination of pesticides in sediments and natural waters using low preconcentration volumes [J].
Ferrer, I ;
Hennion, MC ;
Barcelo, D .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4508-4514
[9]   Automated sample preparation with extraction columns by means of anti-isoproturon immunosorbents for the determination of phenylurea herbicides in water followed by liquid chromatography diode array detection and liquid chromatography atmospheric pressure chemical ionization mass spectrometry [J].
Ferrer, I ;
Pichon, V ;
Hennion, MC ;
Barcelo, D .
JOURNAL OF CHROMATOGRAPHY A, 1997, 777 (01) :91-98
[10]   Development of an immunochemical technique for the analysis of trichlorophenols using theoretical models [J].
Galve, R ;
Camps, F ;
Sanchez-Baeza, F ;
Marco, MP .
ANALYTICAL CHEMISTRY, 2000, 72 (10) :2237-2246