Element speciation analysis by capillary electrophoresis: what are the hints on becoming a standard analytical methodology?

被引:26
作者
Timerbaev, AR [1 ]
机构
[1] Russian Acad Sci, VI Vernadskii Inst Geochem & Analyt Chem, Moscow 117975, Russia
关键词
speciation analysis; capillary electrophoresis; species stability; sample preparation; method validation; detection;
D O I
10.1016/S0003-2670(01)00788-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
While capillary electrophoresis (CE) is growing in importance as a versatile assay for providing element speciation information, there still exist major challenges that limit the technique's practical acceptance. The potential problems in CE applied to speciation analysis are due to certain "noes": no special attention on sample preparation procedures ensuring species stability and avoiding matrix effects, no sufficient care on possible changes in speciation during electrophoresis, no appropriate treatment on method validation and system suitability aspects, no sample enrichment methodologies and detection systems refined for routine use, etc. Approaches to help address these problems are brought into focus and critically evaluated. Recommendations are given how to advance reliable speciation measurements by CE. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:165 / 180
页数:16
相关论文
共 169 条
[21]   Routine determination of major anions in atmospheric aerosols by capillary electrophoresis [J].
DabekZlotorzynska, E ;
Piechowski, M ;
Liu, F ;
Kennedy, S ;
Dlouhy, JF .
JOURNAL OF CHROMATOGRAPHY A, 1997, 770 (1-2) :349-359
[22]   A comparison of capillary electrophoresis using indirect UV absorbance and ICP-MS detection with a self-aspirating nebulizer interface [J].
Day, JA ;
Sutton, KL ;
Soman, RS ;
Caruso, JA .
ANALYST, 2000, 125 (05) :819-823
[23]   How to achieve higher repeatability and reproducibility in capillary electrophoresis [J].
Faller, T ;
Engelhardt, H .
JOURNAL OF CHROMATOGRAPHY A, 1999, 853 (1-2) :83-94
[24]   Determination of sulfide in the leather industry by capillary electrophoresis [J].
Font, J ;
Gutierrez, J ;
Lalueza, J ;
Perez, X .
JOURNAL OF CHROMATOGRAPHY A, 1996, 740 (01) :125-132
[25]   Analysis of nitrate in biological fluids by capillary electrophoresis [J].
Friedberg, MA ;
Hinsdale, ME ;
Shihabi, ZK .
JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) :491-496
[26]  
Fukushi K, 2000, ELECTROPHORESIS, V21, P388, DOI 10.1002/(SICI)1522-2683(20000101)21:2<388::AID-ELPS388>3.0.CO
[27]  
2-Q
[28]  
Fukushi K, 1999, J CHROMATOGR A, V838, P303, DOI 10.1016/S0021-9673(99)00214-9
[29]   Capillary electrophoresis applied to the determination of some seleno compounds [J].
Gilon, N ;
PotinGautier, M .
JOURNAL OF CHROMATOGRAPHY A, 1996, 732 (02) :369-376
[30]  
GLOD B, 1996, ACTA CHROMATOGR, P39