Multi-wall carbon nanotube paste electrode for adsorptive stripping determination of quercetin: A comparison with graphite paste electrode via voltammetry and chronopotentiometry

被引:105
作者
He, JB
Lin, XQ [1 ]
Pan, J
机构
[1] Univ Sci & Technol China, Dept Chem, Anhua 230026, Peoples R China
[2] Hefei Univ Technol, Key Lab Bioproc, Minist Educ, Hefei, Peoples R China
关键词
quercetin; adsorptive-stripping; preconcentration; carbon nanotube; graphite; voltammetry;
D O I
10.1002/elan.200503274
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Adsorptive-stripping voltammetry and chronopotentiometry were used to study the adsorption and oxidation of quercetin at both graphite-nujol paste electrode (GPE) and carbon nanotubes-nujol paste electrode (CNTPE) for the potential application of carbon nanotube to flavonoids determination. As compared with GPE, CNTPE showed very great power to adsorb quercetin and resulted in a considerable signals enhancement. The adsorption isotherm of quercetin on CNTPE was of Langmuir type, and the stripping of quercetin adsorbed on CNTs showed a quasi-reversible oxidation reaction involving two-electron and two-proton. The high adsorbtive activity of CNTPE was contributed to the high specific surface area and the special surface characteristics of carbon nanotubes. The peak current response of differential pulse voltammetry depended linearly on quercetin concentration. A linear equation I-p (mu A) = 0.987c(mu mol L-1) + 0.023 with a correlation coefficient of 0.994 was obtained over the concentration range 0.1 - 1.0 mu mol L-1.
引用
收藏
页码:1681 / 1686
页数:6
相关论文
共 35 条
[21]  
PAMUKCU AM, 1980, CANCER RES, V40, P3468
[22]   Adsorption and electrooxidation of nucleic acids at carbon nanotubes paste electrodes [J].
Pedano, ML ;
Rivas, GA .
ELECTROCHEMISTRY COMMUNICATIONS, 2004, 6 (01) :10-16
[23]   Antimicrobial effects of Finnish plant extracts containing flavonoids and other phenolic compounds [J].
Rauha, JP ;
Remes, S ;
Heinonen, M ;
Hopia, A ;
Kähkönen, M ;
Kujala, T ;
Pihlaja, K ;
Vuorela, H ;
Vuorela, P .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2000, 56 (01) :3-12
[24]   Nanodevices for correlated electrical transport and structural investigation of individual carbon nanotubes [J].
Sagnes, M ;
Broto, JM ;
Raquet, B ;
Vieu, C ;
Conedera, V ;
Dubreuil, P ;
Ondarçuhu, T ;
Laurent, C ;
Flahaut, E .
MICROELECTRONIC ENGINEERING, 2004, 73-4 :689-694
[25]   Determination of some catechol derivatives by a flow injection electrochemiluminescent inhibition method [J].
Sun, YG ;
Cui, H ;
Li, YH ;
Lin, XQ .
TALANTA, 2000, 53 (03) :661-666
[26]  
VERMA AK, 1988, CANCER RES, V48, P5754
[27]   Determination of rutin and other flavonoids by flow-injection/adsorptive stripping voltammetry using nujol-graphite and diphenylether-graphite paste electrodes [J].
Volikakis, GJ ;
Efstathiou, CE .
TALANTA, 2000, 51 (04) :775-785
[28]   Carbon-nanotube based electrochemical biosensors: A review [J].
Wang, J .
ELECTROANALYSIS, 2005, 17 (01) :7-14
[29]  
Wang JX, 2002, ELECTROANAL, V14, P225, DOI 10.1002/1521-4109(200202)14:3<225::AID-ELAN225>3.0.CO
[30]  
2-I